Nitrosamines
Applications | 2011 | Agilent TechnologiesInstrumentation
Nitrosamines are a class of compounds recognized for their strong carcinogenic and mutagenic properties. Their occurrence in environmental and industrial samples, including water and process streams, demands reliable analytical methods capable of rapid, sensitive, and comprehensive screening. Efficient separation and quantification of multiple nitrosamine species support regulatory compliance, risk assessment, and contamination control.
This application note demonstrates a streamlined gas chromatography approach to separate nine nitrosamine compounds within 20 minutes using a single capillary column. The primary objective is to validate the performance of an Agilent FactorFour VF-1701ms fused-silica column in combination with flame ionization detection (FID) for routine environmental analysis.
Sample preparation involved dilution of standard nitrosamine mix to 100 µg/mL in methylene chloride. The chromatographic method parameters were:
The nine nitrosamines were baseline-separated within a 20-minute runtime. Retention time order corresponded to increasing molecular weight and ring structures. The column provided high resolution for closely eluting species such as N-nitrosodimethylamine and N-nitrosomethylethylamine. Peak shapes remained sharp across the temperature gradient, indicating robust performance and minimal thermal degradation.
The described method offers several advantages for environmental and industrial laboratories:
Emerging developments include coupling VF-1701ms columns with tandem mass spectrometry to enhance sensitivity for trace-level nitrosamines. Novel stationary phases and advanced detectors will enable direct analysis of complex matrices such as wastewater effluent and biological fluids. Automation of sample prep and data processing will further accelerate routine monitoring.
This study confirms that the Agilent VF-1701ms capillary column, combined with FID detection, efficiently separates nine nitrosamines in under 20 minutes. The method meets the demands for fast, reliable screening in environmental and quality-control applications, supporting rigorous safety standards and regulatory requirements.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Nitrosamines are a class of compounds recognized for their strong carcinogenic and mutagenic properties. Their occurrence in environmental and industrial samples, including water and process streams, demands reliable analytical methods capable of rapid, sensitive, and comprehensive screening. Efficient separation and quantification of multiple nitrosamine species support regulatory compliance, risk assessment, and contamination control.
Study Objectives and Overview
This application note demonstrates a streamlined gas chromatography approach to separate nine nitrosamine compounds within 20 minutes using a single capillary column. The primary objective is to validate the performance of an Agilent FactorFour VF-1701ms fused-silica column in combination with flame ionization detection (FID) for routine environmental analysis.
Methodology and Used Instrumentation
Sample preparation involved dilution of standard nitrosamine mix to 100 µg/mL in methylene chloride. The chromatographic method parameters were:
- Gas chromatograph: capillary GC system with split injector.
- Column: Agilent FactorFour VF-1701ms, 0.25 mm × 30 m, 0.25 µm film thickness.
- Oven program: hold at 45 °C for 3 min, ramp at 10 °C/min to 280 °C.
- Carrier gas: helium at 60 kPa (≈1 mL/min).
- Injection: split 1:100, 1.0 µL.
- Detection: flame ionization detector (FID).
Main Results and Discussion
The nine nitrosamines were baseline-separated within a 20-minute runtime. Retention time order corresponded to increasing molecular weight and ring structures. The column provided high resolution for closely eluting species such as N-nitrosodimethylamine and N-nitrosomethylethylamine. Peak shapes remained sharp across the temperature gradient, indicating robust performance and minimal thermal degradation.
Benefits and Practical Applications
The described method offers several advantages for environmental and industrial laboratories:
- Fast analysis time, improving sample throughput.
- High resolution of diverse nitrosamine structures in a single run.
- Simple sample preparation with standard solvents.
- Reproducible retention times and reliable quantitation with FID.
Future Trends and Opportunities
Emerging developments include coupling VF-1701ms columns with tandem mass spectrometry to enhance sensitivity for trace-level nitrosamines. Novel stationary phases and advanced detectors will enable direct analysis of complex matrices such as wastewater effluent and biological fluids. Automation of sample prep and data processing will further accelerate routine monitoring.
Conclusion
This study confirms that the Agilent VF-1701ms capillary column, combined with FID detection, efficiently separates nine nitrosamines in under 20 minutes. The method meets the demands for fast, reliable screening in environmental and quality-control applications, supporting rigorous safety standards and regulatory requirements.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Nitrosamines - Analysis of nitrosamines to EPA 8270
2011|Agilent Technologies|Applications
Nitrosamines Analysis of nitrosamines to EPA 8270 Application Note Environmental Authors Introduction Agilent Technologies, Inc. Using GC/MS, an Agilent FactorFour VF-200ms column separates nine nitrosamines according to EPA 8270 in less than 20 minutes. Conditions Technique : GC Column :…
Key words
nitroso, nitrosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminescourtesy, courtesyprinted, printedinjector, injectorusa
Nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. Analysis of nine nitrosamines by gas chromatography using an Agilent FactorFour VF-1301ms column in 22 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFour VF-1301ms, 0.25 mm x 30 m fused…
Key words
nitroso, nitrosonitrosamines, nitrosaminesmethylethylamine, methylethylaminepyrrolidine, pyrrolidinefactorfour, factorfourpiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenine, ninecourtesy, courtesygas
Nitrosamines
2011|Agilent Technologies|Applications
Nitrosamines Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC separation of 13 basic aromatic compounds uses the stabilized 50% phenyl PDMS phase of an Agilent VF-17ms column. Conditions Technique : GC Column : Agilent VF-17ms, 0.25 mm x 30…
Key words
nitroso, nitrosonitoso, nitosomethylethylamine, methylethylaminepyrrolidine, pyrrolidinepiperidine, piperidinemorpholine, morpholinedimethylamine, dimethylaminebutylamine, butylaminediethylamine, diethylaminepropylamine, propylaminediphenylamine, diphenylaminenitrosamines, nitrosaminescourtesy, courtesyprinted, printedinjector
Rapid quantification of 12 nitrosamines in metformin using triple quadrupole GC-MS/MS with Advanced Electron Ionization (AEI)
2021|Thermo Fisher Scientific|Applications
APPLICATION NOTE 000173 Rapid quantification of 12 nitrosamines in metformin using triple quadrupole GC-MS/MS with Advanced Electron Ionization (AEI) Authors: David Lee1, Aaron Lamb1, Andrea Romano2, and Giulia Riccardino2 Thermo Fisher Scientific, Runcorn, UK 2 Thermo Fisher Scientific, Milan, Italy…
Key words
nitroso, nitrosophenylamine, phenylaminenpyr, npyrnepha, nephandma, ndmanmpa, nmpahigh, highndpa, ndpanpip, npipndpha, ndphandea, ndeanmea, nmeandba, ndbandipa, ndipanmor