Aromatic volatile organic compounds

Applications | 2011 | Agilent TechnologiesInstrumentation
GC/MSD, GC columns, Consumables
Industries
Environmental
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


The analysis of aromatic volatile organic compounds is critical for environmental monitoring and industrial quality control. These compounds, commonly found in air and water samples, pose health risks and serve as indicators of pollution sources. Rapid, sensitive, and selective analytical methods enable timely decision making in regulatory compliance and process optimization.

Study Objectives and Overview


This application note describes a gas chromatographic method coupled with mass spectrometric detection to separate and identify nine key aromatic volatiles in under 12 minutes. The primary goal is to demonstrate the performance of an Agilent FactorFour VF-200ms column in achieving high resolution and throughput.

Methodology and Instrumentation


The method employs split-mode GC–MS with the following conditions:
  • Column: Agilent FactorFour VF-200ms (30 m × 0.25 mm, 0.25 µm film)
  • Oven program: 45 °C initial, ramp at 10 °C/min to 325 °C
  • Carrier gas: Helium at ~1.0 mL/min, constant pressure (60 kPa)
  • Injector: Split/Splitless, split ratio 1:100
  • Detector: Mass spectrometer
  • Sample volume: 1 µL

Instrumentation Used


  • Gas chromatograph equipped with split/splitless injector
  • Agilent FactorFour VF-200ms capillary column
  • Helium supply for carrier gas
  • Mass selective detector for compound identification

Key Results and Discussion


The method achieved baseline separation of nine aromatic compounds—benzene, toluene, ethylbenzene, chlorobenzene, ortho-, meta-, and para-xylene isomers, and three dichlorobenzene isomers—within a 12-minute run time. Retention order reflected increasing boiling points and polarity. The VF-200ms column provided sharp peaks and minimal coelution, demonstrating robustness for complex environmental samples.

Practical Applications and Benefits


This rapid GC–MS approach is well suited for routine environmental monitoring, workplace air analysis, and petrochemical quality assurance. Benefits include high throughput, reliable quantitation, and the ability to detect trace-level volatiles with minimal sample preparation.

Future Trends and Opportunities


Emerging directions include coupling with headspace sampling or solid-phase microextraction for enhanced sensitivity, integration of automated data processing algorithms, and portability advances for on-site screening. Time-of-flight and tandem MS technologies may further improve specificity in complex matrices.

Conclusion


The described GC–MS method using the Agilent FactorFour VF-200ms column delivers fast, precise separation of key aromatic volatiles. Its efficiency and reliability make it a valuable tool for environmental and industrial applications, supporting regulatory compliance and process control.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Aromatic volatiles
Aromatic volatiles
2011|Agilent Technologies|Applications
Aromatic volatiles Application Note Environmental Authors Introduction Agilent Technologies, Inc. Separation of 11 aromatic volatiles on an Agilent VF-200ms column in nine minutes. Conditions Technique : GC Column : Agilent FactorFour VF-200ms, 0.25 mm x 30 m (df = 1.0…
Key words
courtesy, courtesyvolatiles, volatilesaromatic, aromaticprinted, printedinjector, injectorusa, usaauthors, authorsprogram, programenvironmental, environmentalsize, sizetechnique, techniquecarrier, carrieridentification, identificationpressure, pressuresolvent
Aromatic volatiles
Aromatic volatiles
2011|Agilent Technologies|Applications
Aromatic volatiles Application Note Environmental Authors Introduction Agilent Technologies, Inc. Analysis of 11 aromatic volatile compounds by gas chromatography using an Agilent FactorFour VF-1301ms column takes less than 15 minutes. Conditions Technique : GC-capillary Column : Agilent FactorFour VF-1301ms, 0.25…
Key words
courtesy, courtesyvolatiles, volatilesaromatic, aromaticprinted, printedinjector, injectorusa, usaauthors, authorsenvironmental, environmentaltechnique, techniquecarrier, carrieridentification, identificationdetector, detectornote, notetemperature, temperaturepeak
Xylenes
Xylenes
2011|Agilent Technologies|Applications
Xylenes Application Note Environmental Authors Introduction Agilent Technologies, Inc. The Agilent VF-200ms type column provides unique separation of VOCs listed in US EPA Methods 524 and 8260, and is the best column to separate xylene isomers. It can be used…
Key words
xylene, xylenemeta, metaxylenes, xylenesortho, orthopara, paraethylbenzene, ethylbenzeneprinted, printedinjector, injectorusa, usaauthors, authorsprogram, programenvironmental, environmentalsize, sizetechnique, techniquecarrier
Chlorinated hydrocarbons
Chlorinated hydrocarbons
2011|Agilent Technologies|Applications
Chlorinated hydrocarbons Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC analysis of eight chlorinated hydrocarbons uses an Agilent FactorFour VF-200ms column to achieve a separation in 22 minutes. Conditions Technique : GC Column : Agilent FactorFour VF-200ms, 0.25 mm…
Key words
hexachloroethane, hexachloroethanehexachlorobutadiene, hexachlorobutadienehexachlorobenzene, hexachlorobenzenecourtesy, courtesychlorinated, chlorinatedhydrocarbons, hydrocarbonsprinted, printedinjector, injectorusa, usaauthors, authorsprogram, programenvironmental, environmentalsize, sizetechnique, techniquecarrier
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike