GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Maintaining Sensitivity andReproducibility with theJetClean Self-CleaningIonSource for Pesticides inFood and Feed

Posters | 2016 | Agilent TechnologiesInstrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Industries
Food & Agriculture
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


Reliable, sensitive detection of pesticide residues in food matrices is critical for consumer safety and regulatory compliance. Advances in ion source technology for gas chromatography–mass spectrometry (GC-MS) can improve method robustness and reduce downtime associated with source contamination.

Study Objectives and Overview


This study compares the analytical performance of a conventional ion source and the Agilent JetClean self-cleaning ion source on the 7010 Series Triple Quadrupole GC/MS platform. Using organic honey extracts spiked with over 170 pesticide analytes, the work evaluates calibration linearity, method detection limits (MDLs), and reproducibility at trace concentration levels.

Methodology and Instrumentation


The investigation employed a 7010 Series Triple Quadrupole GC/MS system equipped with:
  • Standard ion source
  • JetClean self-cleaning ion source operating in Acquire and Clean mode with controlled hydrogen flow
  • Agilent MassHunter software for automated JetClean control
Calibration curves were prepared over the range of 0.12–50 pg/µL for selected pesticides. MDLs were calculated based on ten replicate injections of 1.25 pg/µL spiked honey extract at a 99 % confidence level. Reproducibility was assessed by percent relative standard deviation (%RSD) at both 1.25 pg and 2.5 pg levels.

Key Results and Discussion


Calibration linearity (R2) values exceeded 0.99 for nearly all analytes with both source types, indicating comparable quantitative performance. The JetClean source delivered lower average MDLs (0.081 pg) compared to the standard source (0.151 pg). At the 1.25 pg level, %RSD values were reduced with the JetClean source, reflecting improved precision; at 2.5 pg the two sources yielded similar reproducibility. Improved chromatographic peak shape and baseline stability were particularly noticeable for late-eluting compounds using the JetClean source.

Benefits and Practical Applications


  • Enhanced sensitivity at low-level pesticide residues enables more reliable detection in complex food matrices.
  • Improved precision reduces analytical variability and strengthens data confidence.
  • Self-cleaning functionality minimizes downtime and maintenance burdens.
  • Seamless integration with existing MassHunter software simplifies method setup.

Future Trends and Applications


Ongoing research will quantify the extension of source maintenance intervals afforded by JetClean operation. Further exploration may involve other contaminant classes and high-throughput food safety workflows. Adaptation to emerging tandem MS instruments and automated cleaning schedules could broaden the technology’s applicability.

Conclusion


The JetClean self-cleaning ion source matches or exceeds the performance of a conventional source for quantitative pesticide analysis in honey. It delivers lower MDLs, improved reproducibility at trace levels, and enhanced chromatographic quality, while reducing maintenance demands on the GC-MS system.

References


1 Anderson KA, et al. Modified ion source triple quadrupole mass spectrometer gas chromatograph for polycyclic aromatic hydrocarbon analyses. Journal of Chromatography A. 1419 (2015): 89–98.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Maintaining Sensitivity and Reproducibility with the JetClean Self Cleaning Ion Source for Pesticides in Food and Feed
Maintaining Sensitivity and Reproducibility with the JetClean Self-Cleaning Ion Source for Pesticides in Food and Feed NACRW 2016 P-064 Jessica Westland1 and Elizabeth Almasi2 1Agilent Technologies, Wilmington, DE 19808 USA; 2Agilent Technologies, Santa Clara, CA 95051 USA Introduction Experimental Operation…
Key words
jetclean, jetcleansource, sourceendosulfan, endosulfanmethyl, methyldbcp, dbcpstd, stdheptenophos, heptenophoschlorobenzilate, chlorobenzilatepesticides, pesticideshexachlorobenzene, hexachlorobenzeneparathion, parathionepoxide, epoxideheptachlor, heptachlorendrin, endrinacquire
Maintaining Sensitivity and Reproducibility with the JetCleanSelf-Cleaning Ion Source for Pesticides in Food and Feed
Maintaining Sensitivity and Reproducibility with the JetClean Self-Cleaning Ion Source for Pesticides in Food and Feed Jessica Westland1; Vivian Chen2 and Elizabeth Almasi3; 1Agilent Technologies, Wilmington, DE 19808, USA 2Agilent Technologies, Shanghai Company Limited; 200131,CHINA; 3Agilent ASMS 2016 TP 216…
Key words
jetclean, jetcleansource, sourceendosulfan, endosulfanepoxide, epoxidemethyl, methylheptachlor, heptachlorendrin, endrinstd, stdacquire, acquireirgarol, irgaroltune, tunevivian, viviantemperature, temperaturedbcp, dbcpelizabeth
Maintaining Sensitivity and Reproducibility with the Agilent JetClean Self-Cleaning Ion Source for Pesticides in Food and Feed
Maintaining Sensitivity and Reproducibility with the Agilent JetClean Self-Cleaning Ion Source for Pesticides in Food and Feed Application Note Author Abstract Jessica Westland Approximately 200 various pesticides were analyzed in organic honey extract on Agilent Technologies, Inc. the Agilent 7010A…
Key words
jetclean, jetcleanagilent, agilenthoney, honeymin, mintime, timewithout, withoutcleaning, cleaningself, selfmasshunter, masshunterendrin, endrinpuu, puusource, sourcetransitions, transitionsuse, usepesticide
Rapid Analysis of 303 Pesticide Residues inGreen Bean Using Triple Quadrupole GC-MS/MS
Application Note: 52022 Rapid Analysis of 303 Pesticide Residues in Green Bean Using Triple Quadrupole GC-MS/MS Chen Shubing, Yu Xuejun, Ningbo CIQ, Zhejiang, China Ye Fangting, Thermo Fisher Scientific, Shanghai, China Lu Ling, Thermo Fisher Scientific, Austin, TX, USA Extraction…
Key words
pesticide, pesticidemethyl, methylsrm, srmtransitions, transitionsethyl, ethylmean, meanspe, spequantum, quantummsn, msnbhc, bhcmetominostrobin, metominostrobincompounds, compoundsclodinafop, clodinafopflamprop, flamproppropargyl
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike