GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Author
Phenomenex
Phenomenex
Phenomenex is a global technology leader committed to developing novel analytical chemistry solutions that solve the separation and purification challenges of researchers in industrial, government and academic laboratories.
Tags
Article
Academy
LinkedIn Logo

How to Protect Your GC Column - Part 1

We, 4.2.2026
| Original article from: Phenomenex
Dirty samples can quickly damage your GC column and shorten its lifetime. Learn simple, proven ways to protect your column, improve performance, and reduce downtime. Part 1 focuses on smart sample preparation.
<p><strong>Phenomenex: </strong>How to Protect Your GC Column - Part 1</p>

Phenomenex: How to Protect Your GC Column - Part 1

Protecting your GC column and instrument components from exposure to dirty samples is important. Non-volatile or high molecular weight components can contaminate the stationary phase, causing poor peak resolution, lower accuracy, and poor column lifetime. Cutting off the damaged portion of column tubing will often restore your column’s performance, but over time performance will degrade to a point where the column can no longer be used. If you are experiencing rapid degradation of column performance, there are several simple ways to help protect your column and increase its lifetime.

Ensure Proper Sample Preparation

Sample filtration and SPE products can help to eliminate or mitigate contaminants and matrix effects, resulting in longer column lifetimes and increased signal-to-noise ratios. Not only will proper sample preparation prolong the life of the analytical column, it will also protect your system and improve method accuracy by removing unwanted contaminants or particles. Sample filtration in particular, helps reduce system downtime and equipment replacement, resulting in time and money savings. Filtering samples before injection is one of the quickest (and easiest!) way to protect your GC column and lengthen lifetime.

Use A Guard or Integrated Guard Column

With integrated guard columns, unlike traditional guard columns, the guard is built directly into the analytical column in one continuous length of tubing. Traditional columns may be difficult to seal and can leak after normal column maintenance, whilst integrated guards such as the Zebron™ Guardian system provide the same inert column protection, but eliminate the possibility of leaks.

Traditional guard columns such as Zebron Z-Guard, are 5 or 10 meter pieces of deactivated tubing that are connected to an analytical column using a glass press-fit connector. The tubing acts like a trap for non-volatile residues that would otherwise damage the stationary phase of your analytical column.

In addition to providing column protection, traditional guard columns can also be used for solvent focusing, or for large volume injection when the guard section is long (8 to 10 meters). When using a traditional guard column, success lies in proper installation. Ensure that column ends are cut cleanly and that any polyimide resin used is cured.

Look out for our second part on how to protect your GC column next week!

Phenomenex
LinkedIn Logo
 

Related content

Total Hydrocarbon Impurity Analysis in PEM Fuel Cell Grade Hydrogen Using the Agilent 8890 GC-FID System

Applications
| 2026 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Energy & Chemicals

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technical notes
| 2026 | Agilent Technologies
Instrumentation
Consumables, GC columns
Manufacturer
Agilent Technologies
Industries
Other

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Applications
| 2025 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Energy & Chemicals
 

Related articles

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions
Article | Laboratories

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions

Explore alternatives to traditional ducted fume hoods, including glove boxes, snorkel systems, ductless hoods, and specialized containment solutions for safer, energy-efficient laboratories.
Organomation
tag
share
more
Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)
Presentation | Video

Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)

GC×GC-HRTOFMS enables fast and reliable screening of PFAS and emerging contaminants in complex consumer goods, combining EI/PCI/NCI and mass defect workflows for confident identification.
The Multidimensional Chromatography Workshop
tag
share
more
News from LabRulezGCMS Library - Week 09, 2026
Article | Application

News from LabRulezGCMS Library - Week 09, 2026

This week we bring you application notes by Agilent Technologies, Shimadzu and Waters Corporation and presentation by MDCW / William & Mary!
LabRulez
tag
share
more
Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality
Article | Product

Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality

Helium as a critical resource in GC: how intelligent gas management and Helium Saver™ can reduce helium use by up to 67% while supporting green chromatography.
Watrex Praha
tag
share
more
 

Related content

Total Hydrocarbon Impurity Analysis in PEM Fuel Cell Grade Hydrogen Using the Agilent 8890 GC-FID System

Applications
| 2026 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Energy & Chemicals

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technical notes
| 2026 | Agilent Technologies
Instrumentation
Consumables, GC columns
Manufacturer
Agilent Technologies
Industries
Other

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Applications
| 2025 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Energy & Chemicals
 

Related articles

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions
Article | Laboratories

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions

Explore alternatives to traditional ducted fume hoods, including glove boxes, snorkel systems, ductless hoods, and specialized containment solutions for safer, energy-efficient laboratories.
Organomation
tag
share
more
Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)
Presentation | Video

Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)

GC×GC-HRTOFMS enables fast and reliable screening of PFAS and emerging contaminants in complex consumer goods, combining EI/PCI/NCI and mass defect workflows for confident identification.
The Multidimensional Chromatography Workshop
tag
share
more
News from LabRulezGCMS Library - Week 09, 2026
Article | Application

News from LabRulezGCMS Library - Week 09, 2026

This week we bring you application notes by Agilent Technologies, Shimadzu and Waters Corporation and presentation by MDCW / William & Mary!
LabRulez
tag
share
more
Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality
Article | Product

Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality

Helium as a critical resource in GC: how intelligent gas management and Helium Saver™ can reduce helium use by up to 67% while supporting green chromatography.
Watrex Praha
tag
share
more
 

Related content

Total Hydrocarbon Impurity Analysis in PEM Fuel Cell Grade Hydrogen Using the Agilent 8890 GC-FID System

Applications
| 2026 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Energy & Chemicals

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technical notes
| 2026 | Agilent Technologies
Instrumentation
Consumables, GC columns
Manufacturer
Agilent Technologies
Industries
Other

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Applications
| 2025 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Energy & Chemicals
 

Related articles

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions
Article | Laboratories

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions

Explore alternatives to traditional ducted fume hoods, including glove boxes, snorkel systems, ductless hoods, and specialized containment solutions for safer, energy-efficient laboratories.
Organomation
tag
share
more
Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)
Presentation | Video

Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)

GC×GC-HRTOFMS enables fast and reliable screening of PFAS and emerging contaminants in complex consumer goods, combining EI/PCI/NCI and mass defect workflows for confident identification.
The Multidimensional Chromatography Workshop
tag
share
more
News from LabRulezGCMS Library - Week 09, 2026
Article | Application

News from LabRulezGCMS Library - Week 09, 2026

This week we bring you application notes by Agilent Technologies, Shimadzu and Waters Corporation and presentation by MDCW / William & Mary!
LabRulez
tag
share
more
Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality
Article | Product

Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality

Helium as a critical resource in GC: how intelligent gas management and Helium Saver™ can reduce helium use by up to 67% while supporting green chromatography.
Watrex Praha
tag
share
more
 

Related content

Total Hydrocarbon Impurity Analysis in PEM Fuel Cell Grade Hydrogen Using the Agilent 8890 GC-FID System

Applications
| 2026 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Energy & Chemicals

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technical notes
| 2026 | Agilent Technologies
Instrumentation
Consumables, GC columns
Manufacturer
Agilent Technologies
Industries
Other

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Applications
| 2025 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Energy & Chemicals
 

Related articles

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions
Article | Laboratories

Alternatives to Traditional Fume Hoods: A Comprehensive Guide to Laboratory Containment Solutions

Explore alternatives to traditional ducted fume hoods, including glove boxes, snorkel systems, ductless hoods, and specialized containment solutions for safer, energy-efficient laboratories.
Organomation
tag
share
more
Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)
Presentation | Video

Exploring PFAS in consumer goods using GCxGC-high-resolution mass spectrometry (David Alonso, MDCW 2026)

GC×GC-HRTOFMS enables fast and reliable screening of PFAS and emerging contaminants in complex consumer goods, combining EI/PCI/NCI and mass defect workflows for confident identification.
The Multidimensional Chromatography Workshop
tag
share
more
News from LabRulezGCMS Library - Week 09, 2026
Article | Application

News from LabRulezGCMS Library - Week 09, 2026

This week we bring you application notes by Agilent Technologies, Shimadzu and Waters Corporation and presentation by MDCW / William & Mary!
LabRulez
tag
share
more
Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality
Article | Product

Green Chromatography in Practice: How to Reduce Helium Consumption in GC Without Compromising Data Quality

Helium as a critical resource in GC: how intelligent gas management and Helium Saver™ can reduce helium use by up to 67% while supporting green chromatography.
Watrex Praha
tag
share
more
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike