GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Author
ALS Czech Republic
ALS Czech Republic
For more than 40 years, ALS has provided testing and technical solutions to clients all over the world in a wide range of industries. We have built our global reputation by embracing the latest technologies and innovative methodologies to deliver high quality testing services to clients. ALS is able to leverage a multifaceted international team while remaining agile enough to provide local expertise and personalized solutions to every one of our clients.
Tags
Article
Environment
LinkedIn Logo

EnviroMail™14/Europe: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics

Th, 3.7.2025
| Original article from: ALS Czech republic
ALS demonstrates how proper Florisil clean-up greatly reduces false positive detections of C10-C40 hydrocarbons caused by biogenic substances in soils and organic-rich materials.
<p><strong>ALS Czech republic:</strong> Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics</p>

ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics

Wood waste, manure, and organic-rich soils such as peat or compost are typical and well-known sources of false positive interferences in the determination of total petroleum hydrocarbons (TPH; C10-C40) due to the presence of organic compounds of natural origin.

Clean-up of the extract with Florisil should achieve the removal of most of the interfering compounds of natural origin, based on the different polarity of these compounds from hydrocarbons originating from mineral oils. In some cases, however, the adsorption capacity of the Florisil used may not be sufficient.

ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 1: Peatland.ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 1: Peatland.

Importance of C10-C40 determination

The determination of petroleum hydrocarbons, i.e. non-polar extractables in the C10-C40 range, sometimes referred to as TPH, is a non-selective method where the compounds tend to be part of different mixtures.

The content of C10-C40 hydrocarbons is a legally monitored parameter. In the European Union, it is Council Decision 2003/33/EC, which sets out the conditions under which waste can be disposed of in the relevant group of landfills. The limit value of C10-C40 for inert waste (500 mg/kg) is specified.

TPH false positives due to natural substances

The principle of the analysis of solid or aqueous matrices for the determination of C10-C40 is their extraction into an organic solvent, where the Florisil-purified extract is analysed on a gas chromatograph with a flame ionisation detector (GC-FID). The total peak area between n-decane (n-C10H22) and n-tetracontane (n-C40H82) is measured.

According to EN ISO 16703, EN ISO 9377-2 and EN 14039, all hydrocarbons in the distillation range C10-C40 with a boiling point between 175°C and 525°C, n-alkanes from C10H22 to C40H82, iso-alkanes, cyclo-alkanes, alkylbenzenes, alkylnaphthalenes and polycyclic aromatic hydrocarbons are determined as hydrocarbons in the distillation range C10-C40, unless they are adsorbed on Florisil during clean-up.
However, a number of extractable compounds can also be detected on GC-FID which can be defined as those of non-petroleum origin. In particular, polar compounds from the fatty acid group, alcohols, sterols or other steroidal substances etc., may interfere with the determination of C10-C40 petroleum hydrocarbons in natural materials or organic soils.

Peat formed by the accumulation of partially decayed vegetation or organic matter creates ecosystems in many places in Europe. Samples from these sites can easily exceed the most stringent local regulatory standards for C10-C40 due to the interference from biogenic compounds that are characteristic in their chromatographic profiles. Wood waste, compost, fertiliser-treated soils or tree needles and wood chips can also have a significant impact on false positive C10-C40 petroleum hydrocarbon results.
Florisil is also an integral part of the procedure for the analysis of C10-C40 in aqueous samples. It can easily eliminate some non-biogenic polar interferences, which can be, for example, various surfactants contained in some detergents.

Florisil clean-up standards for C10-C40 determination

Florisil is highly polar and the large active surface area of the molecules makes this amorphous form of magnesium silicate highly effective for the capture of polar compounds, typically their oxygenated forms. On the other hand, non-polar compounds typical of C10-C40 petroleum hydrocarbons remain in the extract and are analysed by GC-FID.

The procedure for Florisil clean-up of the sample extract is based on the above standards, where the use of 2 g Florisil for clean-up through the column (column chromatography) is recommended. However, the use of in situ clean-up techniques is also acceptable, provided that the results are equivalent to those of the Florisil column test.

Based on practical experience, it can be underlined that clean-up of the extract through a Florisil loaded column is more effective in removing interfering polar compounds. The gradual flow of the extract through the Florisil-filled column provides a greater potential for interaction with new molecules of active Florisil than the case with the in situ clean-up.

Minimising false positives

ALS Laboratories, of course, provide this efficient form of removal of interfering substances. In order to provide an optimal clean-up for samples where biogenic interferences are expected, a superior form of clean-up step through two columns, i.e. twice the amount of Florisil than is standardised in ISO standards, has also been developed.

Figure 2 shows the assembled apparatus for both standard and above-standard clean-up.

ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 2: Column and double-column apparatus for clean-up of extracts prior to GC determination of C10-C40.ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 2: Column and double-column apparatus for clean-up of extracts prior to GC determination of C10-C40.

An example of how effectively Florisil cleaning works can be seen in the results of C10-C40 determination on a real soil sample. In Figure 3, the chromatographic profile is typical of the presence of peat when the extract has not been purified via Florisil prior to GC FID analysis (C10-C40: 428 mg/kg dry sample).

In contrast, Figure 4 shows how effective the clean-up was (C10-C40: 33.3 mg/kg dry sample). For this real sample example, up to 93% of the finding in the C10-C40 fraction was shown to be of biogenic origin.

ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 3: Chromatographic profile of the extract before clean-up with Florisil (C10-C40: 428 mg/kg DW).ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 3: Chromatographic profile of the extract before clean-up with Florisil (C10-C40: 428 mg/kg DW).

ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 4: Chromatographic profile of the extract after clean-up with Florisil (C10-C40: 33.3 mg/kg DW).ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 4: Chromatographic profile of the extract after clean-up with Florisil (C10-C40: 33.3 mg/kg DW).

Chromatogram and qualitative assessment of contamination - oil pollution

Thanks to our highly qualified and professional staff, ALS Laboratories are always ready to advise and in most cases even specify the origin of the oil contamination.

After consultation, a chromatogram or even a more thorough qualitative assessment of the contamination can be provided after comparison of the chromatographic profile with the measured in-house library of standards on the GC-FID. An example of such a report in an appendix to the results may be the comparison in Figure 5 below.

ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 5: Resulting chromatographic profile comparison for qualitative assessment of the origin of sample contamination.ALS Czech republic: Resolving False Positive Detections of Petroleum Hydrocarbons Originating from Natural Organics: Figure 5: Resulting chromatographic profile comparison for qualitative assessment of the origin of sample contamination.

ALS Czech Republic
LinkedIn Logo
 

Related content

Analysis of Total Aromatic Content in Motor Gasoline by ASTM D5769 Using an Agilent 8850/5977C GC/MSD System

Applications
| 2025 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

A Chemometric Approach for Ambient Air Monitoring Using Thermal Desorption GC/MS

Applications
| 2025 | Agilent Technologies
Instrumentation
Thermal desorption, GC/MSD, GC/SQ
Manufacturer
Agilent Technologies, Markes
Industries
Environmental

PFAS in Bottled Water: A Simple Approach Using HS-SPME GC/MS/MS for Volatile Contaminant Analysis

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
HeadSpace, SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Advancing PFAS Detection in Drinking Water: GC-MS as a Complementary Technique to LC-MS for Closing PFAS Mass Balance

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Performance evaluation of GC-MS/MS for Dioxin analysis with amendments to EU Regulations 644/2017 and 771/2017 for food and feed

Posters
| 2025 | Thermo Fisher Scientific (ASMS)
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Considerations when working with solid samples and SPE
Article | Academy

Considerations when working with solid samples and SPE

Solid phase extraction enables clean-up, pre-concentration, and solvent switching. Proper solvent choice and SPE mode are key for effective solid sample preparation.
Phenomenex
tag
share
more
EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders
Article | Environment

EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders

ALS is committed to climate action and sustainability, aiming for Net Zero by 2050. Through innovation and science, we strive to make a meaningful impact and share progress with clients.
ALS Czech Republic
tag
share
more
Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)
Presentation | Video

Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)

Using HSSE and GC×GC-TOF MS, we investigate volatile migration in packaged oats. Advanced profiling reveals how different packaging materials impact aroma, safety, and product differentiation.
The Multidimensional Chromatography Workshop
tag
share
more
New material enables chemical production using sunlight and water
Article | Science and research

New material enables chemical production using sunlight and water

Scientists developed a catalyst that uses sunlight and water to hydrogenate a wide range of organics with high yield and selectivity—no gas hydrogen or harsh conditions needed.
CATRIN
tag
share
more
 

Related content

Analysis of Total Aromatic Content in Motor Gasoline by ASTM D5769 Using an Agilent 8850/5977C GC/MSD System

Applications
| 2025 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

A Chemometric Approach for Ambient Air Monitoring Using Thermal Desorption GC/MS

Applications
| 2025 | Agilent Technologies
Instrumentation
Thermal desorption, GC/MSD, GC/SQ
Manufacturer
Agilent Technologies, Markes
Industries
Environmental

PFAS in Bottled Water: A Simple Approach Using HS-SPME GC/MS/MS for Volatile Contaminant Analysis

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
HeadSpace, SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Advancing PFAS Detection in Drinking Water: GC-MS as a Complementary Technique to LC-MS for Closing PFAS Mass Balance

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Performance evaluation of GC-MS/MS for Dioxin analysis with amendments to EU Regulations 644/2017 and 771/2017 for food and feed

Posters
| 2025 | Thermo Fisher Scientific (ASMS)
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Considerations when working with solid samples and SPE
Article | Academy

Considerations when working with solid samples and SPE

Solid phase extraction enables clean-up, pre-concentration, and solvent switching. Proper solvent choice and SPE mode are key for effective solid sample preparation.
Phenomenex
tag
share
more
EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders
Article | Environment

EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders

ALS is committed to climate action and sustainability, aiming for Net Zero by 2050. Through innovation and science, we strive to make a meaningful impact and share progress with clients.
ALS Czech Republic
tag
share
more
Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)
Presentation | Video

Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)

Using HSSE and GC×GC-TOF MS, we investigate volatile migration in packaged oats. Advanced profiling reveals how different packaging materials impact aroma, safety, and product differentiation.
The Multidimensional Chromatography Workshop
tag
share
more
New material enables chemical production using sunlight and water
Article | Science and research

New material enables chemical production using sunlight and water

Scientists developed a catalyst that uses sunlight and water to hydrogenate a wide range of organics with high yield and selectivity—no gas hydrogen or harsh conditions needed.
CATRIN
tag
share
more
 

Related content

Analysis of Total Aromatic Content in Motor Gasoline by ASTM D5769 Using an Agilent 8850/5977C GC/MSD System

Applications
| 2025 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

A Chemometric Approach for Ambient Air Monitoring Using Thermal Desorption GC/MS

Applications
| 2025 | Agilent Technologies
Instrumentation
Thermal desorption, GC/MSD, GC/SQ
Manufacturer
Agilent Technologies, Markes
Industries
Environmental

PFAS in Bottled Water: A Simple Approach Using HS-SPME GC/MS/MS for Volatile Contaminant Analysis

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
HeadSpace, SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Advancing PFAS Detection in Drinking Water: GC-MS as a Complementary Technique to LC-MS for Closing PFAS Mass Balance

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Performance evaluation of GC-MS/MS for Dioxin analysis with amendments to EU Regulations 644/2017 and 771/2017 for food and feed

Posters
| 2025 | Thermo Fisher Scientific (ASMS)
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Considerations when working with solid samples and SPE
Article | Academy

Considerations when working with solid samples and SPE

Solid phase extraction enables clean-up, pre-concentration, and solvent switching. Proper solvent choice and SPE mode are key for effective solid sample preparation.
Phenomenex
tag
share
more
EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders
Article | Environment

EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders

ALS is committed to climate action and sustainability, aiming for Net Zero by 2050. Through innovation and science, we strive to make a meaningful impact and share progress with clients.
ALS Czech Republic
tag
share
more
Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)
Presentation | Video

Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)

Using HSSE and GC×GC-TOF MS, we investigate volatile migration in packaged oats. Advanced profiling reveals how different packaging materials impact aroma, safety, and product differentiation.
The Multidimensional Chromatography Workshop
tag
share
more
New material enables chemical production using sunlight and water
Article | Science and research

New material enables chemical production using sunlight and water

Scientists developed a catalyst that uses sunlight and water to hydrogenate a wide range of organics with high yield and selectivity—no gas hydrogen or harsh conditions needed.
CATRIN
tag
share
more
 

Related content

Analysis of Total Aromatic Content in Motor Gasoline by ASTM D5769 Using an Agilent 8850/5977C GC/MSD System

Applications
| 2025 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

A Chemometric Approach for Ambient Air Monitoring Using Thermal Desorption GC/MS

Applications
| 2025 | Agilent Technologies
Instrumentation
Thermal desorption, GC/MSD, GC/SQ
Manufacturer
Agilent Technologies, Markes
Industries
Environmental

PFAS in Bottled Water: A Simple Approach Using HS-SPME GC/MS/MS for Volatile Contaminant Analysis

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
HeadSpace, SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Advancing PFAS Detection in Drinking Water: GC-MS as a Complementary Technique to LC-MS for Closing PFAS Mass Balance

Posters
| 2025 | Shimadzu (ASMS)
Instrumentation
SPME, GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Environmental

Performance evaluation of GC-MS/MS for Dioxin analysis with amendments to EU Regulations 644/2017 and 771/2017 for food and feed

Posters
| 2025 | Thermo Fisher Scientific (ASMS)
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Thermo Fisher Scientific
Industries
Food & Agriculture
 

Related articles

Considerations when working with solid samples and SPE
Article | Academy

Considerations when working with solid samples and SPE

Solid phase extraction enables clean-up, pre-concentration, and solvent switching. Proper solvent choice and SPE mode are key for effective solid sample preparation.
Phenomenex
tag
share
more
EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders
Article | Environment

EnviroMail™12/Europe: ALS Net Zero Commitments & Roadmap in Support of our Staff, Clients, Communities & Shareholders

ALS is committed to climate action and sustainability, aiming for Net Zero by 2050. Through innovation and science, we strive to make a meaningful impact and share progress with clients.
ALS Czech Republic
tag
share
more
Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)
Presentation | Video

Investigating the impact of packaging on oat volatiles using GC×GC–TOF MS (Steve Smith, MDCW 2025)

Using HSSE and GC×GC-TOF MS, we investigate volatile migration in packaged oats. Advanced profiling reveals how different packaging materials impact aroma, safety, and product differentiation.
The Multidimensional Chromatography Workshop
tag
share
more
New material enables chemical production using sunlight and water
Article | Science and research

New material enables chemical production using sunlight and water

Scientists developed a catalyst that uses sunlight and water to hydrogenate a wide range of organics with high yield and selectivity—no gas hydrogen or harsh conditions needed.
CATRIN
tag
share
more
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike