GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Manufacturer
Organomation
Organomation
Organomation, founded in 1959, designs and manufactures high-quality nitrogen evaporators and extraction systems. Known for innovation and durability, their lab instruments are used globally for efficient sample preparation with strong customer support.
Distributor
Organomation
Organomation, founded in 1959, designs and manufactures high-quality nitrogen evaporators and extraction systems. Known for innovation and durability, their lab instruments are used globally for efficient sample preparation with strong customer support.
Distributor
LabRulez
Stop looking and start finding. We are your source for news, applications, products, articles, theory, job postings, webinars, e-shop or bazaar in the world of analytical chemistry.
Organomation 12 Position N-EVAP Nitrogen EvaporatorThe 12 position N-EVAP nitrogen evaporator is a compact unit that allows for up to 12 samples to be evaporated simultaneously. At each individual sample position, the gas flow can be controlled via a precision needle valve.
Features

Organomation 12 Position N-EVAP Nitrogen Evaporator

The 12 position N-EVAP nitrogen evaporator (cat# 11155) is a compact unit that allows for up to 12 samples to be evaporated simultaneously. At each individual sample position, the gas flow can be controlled via a precision needle valve. This is ideal for the simultaneous evaporation of samples with varying evaporation end points. The sample tray has a spring tensioner which allows any test tube between 10-30 mm to be processed without any modifications to the instrument. An optional small sample holder allows samples with an outside diameter of 5-16 mm to be processed.

First introduced in 1959 as The Meyer N-EVAP, the 12 position N-EVAP (cat# 11155) was the first nitrogen dryer created by Organomation. It has proven to be an extremely durable, time tested and highly affordable member of Organomation’s N-EVAP line. These economical units provide controlled concentration of sample vials through the application of nitrogen gas within a heated water bath. The N-EVAP’s circular rotating design permits each sample to be accessible from the front of the instrument for easy insertion and retrieval. The chrome plated needle valves are individually milled from solid brass, enabling precise, uniform adjustments for your nitrogen blow down. This promotes efficient and safe sample reduction with minimal nitrogen waste.

  • Small Footprint: N-EVAP Model 111 requires under one square foot of bench space
  • Flexible: An adjustable sample holder design fits a wide variety of sample tubes and vials at once
  • Customizable: Options are available for use with acidic or flammable solvents, heat- or water-sensitive samples, and more
  • Individualized Control: Optimize evaporation of diverse samples with individual gas flow control at each vial

Organomation 12 Position N-EVAP Nitrogen Evaporator .Organomation 12 Position N-EVAP Nitrogen Evaporator .

STANDARD FEATURES

  • Nitrogen filter
  • Adjustable flow meter, 0-10 LPM
  • High pressure phthalate free tubing for safety
  • High temperature limit switch for safety
  • Dual band spring hoist assembly (except in dry bath model)
  • Precision needle valve tube assembly
  • Needles, 4 inch x 19 gauge with chrome plated brass hub and stainless steel shaft

OPTIONS 

  • 220v wiring harness (Option Code# -2), Cat# 11155-2
  • Z-Purge/positive pressure purge case (Option Code# -Z), Cat# 11155-Z
  • Acid resistant coating on instrument and needles (Option Code# -RT), Cat# 11155-RT

SPECS

12p N-EVAP (Water Bath)

  • Bath Type: Water
  • Instrumental Catalog Number: 11155
  • Number of Sample Positions: 12
  • Overall Dimension (w x d x h): 13 x 11 x 31 in / 33 x 28 x 79 cm
  • Sample Holder Layout: Circular
  • Gas Manifold Layout: Single Ring
  • Test Tube Range (Standard Sample Holder): 10–30 mm OD
  • Test Tube Range (Optional Sample Holder): 5–16 mm OD
  • Gas Flow Meter: 0–10 L/min
  • Stainless Steel Needles (Length × Gauge): 4.0 in × 19 ga / 102 mm × 19 ga
  • Sample Tray Lift Mechanism: Dual Band Spring Hoist Assembly
  • Rotating, Leak Tight Gas Fitting: Standard
  • Standard Gas Input Range: 20–30 psig
  • Optional Gas Input Range with Optional Pressure Reducing Regulator: 30–160 psig
  • Acid Resistant Coating (Option Code -RT): Optional
Heating Device Specs
  • Model Number: 5585
  • Heating Medium: Water
  • Inside Dimensions (Diameter × Depth): 8.5 × 4.5 in / 21.6 × 11.4 cm
  • Outside Dimensions (w × d × h): 13 × 11 × 7 in / 33 × 28 × 18 cm
  • Total Wattage: 550 W
  • Bath Temperature Range: 30–90 °C
  • Temperature Controller Type: Mechanical Thermostat
  • Controller Accuracy: ± 2 °C

12p N-EVAP (Dry Bath)

  • Bath Type: Dry
  • Instrumental Catalog Number: 11155-DA
  • Number of Sample Positions: 12
  • Overall Dimension (w x d x h): 13 x 11 x 27.5 in / 33 x 28 x 70 cm
  • Sample Holder Layout: Circular
  • Gas Manifold Layout: Single Ring
  • Test Tube Range (Standard Sample Holder): 10–30 mm OD
  • Test Tube Range (Optional Sample Holder): 5–16 mm OD
  • Gas Flow Meter: 0–10 L/min
  • Stainless Steel Needles (Length × Gauge): 4.0 in × 19 ga / 102 mm × 19 ga
  • Sample Tray Lift Mechanism: None/Fixed
  • Rotating, Leak Tight Gas Fitting: N/A
  • Standard Gas Input Range: 20–30 psig
  • Optional Gas Input Range with Optional Pressure Reducing Regulator: 30–160 psig
  • Acid Resistant Coating (Option Code -RT): Optional
Heating Device Specs
  • Model Number: 5085
  • Heating Medium: Aluminum Beads (Glass Beads in RT Models)
  • Inside Dimensions (Diameter × Depth): 8.5 × 4.5 in / 21.6 × 11.4 cm
  • Outside Dimensions (w × d × h): 13 × 11 × 7 in / 33 × 28 × 18 cm
  • Total Wattage: 500 W
  • Bath Temperature Range: 40–130 °C
  • Temperature Controller Type: Mechanical Thermostat
  • Controller Accuracy: ± 2 °C

12p N-EVAP (No Bath)

  • Bath Type: None
  • Instrumental Catalog Number: 11155-O
  • Number of Sample Positions: 12
  • Overall Dimension (w x d x h): 12 × 8 × 31 in / 33 × 28 × 79 cm
  • Sample Holder Layout: Circular
  • Gas Manifold Layout: Single Ring
  • Test Tube Range (Standard Sample Holder): 10–30 mm OD
  • Test Tube Range (Optional Sample Holder): 5–16 mm OD
  • Gas Flow Meter: 0–10 L/min
  • Stainless Steel Needles (Length × Gauge): 4.0 in × 19 ga / 102 mm × 19 ga
  • Sample Tray Lift Mechanism: Dual Band Spring Hoist Assembly
  • Rotating, Leak Tight Gas Fitting: Standard
  • Standard Gas Input Range: 20–30 psig
  • Optional Gas Input Range with Optional Pressure Reducing Regulator: 30–160 psig
  • Acid Resistant Coating (Option Code -RT): Optional

MODELS

Catalog Number  /   Bath Type
  • 11155: Water Bath
  • 11155-NT: No Teflon, Water Bath*
  • 11155-DA: Dry Bath
  • 11155-O: No Bath

* No Teflon (-NT) units designed for PFAS analysis using EPA methods 533, 537 and 537.1.
**All “-O” models come with a base and stand assembly instead of a heated bath. These instruments are designed for evaporation procedures performed at ambient temperature.

ACCESSORIES

  • Small vessel sample holder, for vial outside diameters of 5-16 mm (cat# NA1132)
  • Nitrogen generator (cat# NA1955)
  • Pasteur pipette adapters (cat# NA0636)
  • Pressure reducing regulator 0-160 psi (cat# NA0630)
  • High temperature silicone fluid (cat# NA1240)
  • Various needle sizes and gauges

REPLACEMENT PARTS

  • P0627: Valve Tube Assembly – Post 1997
  • P0607: Luer & washer for N-EVAP valve tube
  • P0634: Tube Fitting nylon 3 part for N-EVAP valve tube
Manufacturer
Organomation
Organomation
Organomation, founded in 1959, designs and manufactures high-quality nitrogen evaporators and extraction systems. Known for innovation and durability, their lab instruments are used globally for efficient sample preparation with strong customer support.
Distributor
Organomation
Organomation, founded in 1959, designs and manufactures high-quality nitrogen evaporators and extraction systems. Known for innovation and durability, their lab instruments are used globally for efficient sample preparation with strong customer support.
Distributor
LabRulez
Stop looking and start finding. We are your source for news, applications, products, articles, theory, job postings, webinars, e-shop or bazaar in the world of analytical chemistry.
 

News

Toggle
Protecting Europe's Waters: Reliable Sample Prep for Water Framework Directive Compliance
Article | Environment

Protecting Europe's Waters: Reliable Sample Prep for Water Framework Directive Compliance

Stringent Water Framework Directive requirements drive high analytical sensitivity. EQS limits, GC-MS determination of priority substances, and the critical role of sample preparation in practice.
Organomation
tag
share
more
Safe Sample Prep for PFAS Analysis: PTFE-Free Concentrators Explained
Article | Science and research

Safe Sample Prep for PFAS Analysis: PTFE-Free Concentrators Explained

Organomation explains how PFAS-free nitrogen evaporators eliminate fluoropolymer contamination by replacing PTFE tape with a PTFE-free sealant, ensuring safe and reliable PFAS sample preparation.