New Approaches to the Developmentof GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods
Technical notes | 2001 | Agilent TechnologiesInstrumentation
Gas chromatography coupled with mass spectrometry in selected ion monitoring (GC/MS-SIM) remains a cornerstone technique for trace-level analysis across environmental, pharmaceutical and industrial laboratories. Retention-time locking and automated SIM setup address long-standing challenges in method development, reproducibility and database maintenance. These innovations enhance sensitivity, streamline workflows and ensure reliable, transferable methods even after column maintenance or replacement.
This application note presents a systematic strategy for creating robust GC/MS-SIM quantitation methods. The approach integrates optimized chromatographic separation, retention-time locking via Agilent ChemStation, and the AutoSIM macro to automate SIM group generation, exemplified with an 83-compound EPA 8270 scenario.
The workflow consists of four key steps: identifying an optimal GC separation, locking retention times, building an MS quantitation database using full-scan data, and auto-generating SIM acquisition methods. Critical SIM setup parameters include minimum time between peaks, dwell times, group start location and peak broadening factors. Iterative adjustment ensures adequate scans per peak and accommodates complex analyte lists.
Implementation of retention-time locking produced stable retention windows unaffected by column changes, eliminating the need for frequent database updates. AutoSIM generated SIM methods with as many as 19 SIM groups for 83 analytes after fine-tuning the minimum gap parameter. The combined strategy reduced setup complexity, improved reproducibility and ensured sufficient scan density across peaks.
The Agilent retention-time locking and AutoSIM features provide a cohesive, automated solution for GC/MS-SIM method development. By standardizing retention times and automating SIM group creation, laboratories can achieve sensitive, reproducible analyses with minimal upkeep, supporting diverse applications from environmental testing to industrial process control.
GC/MSD, GC/SQ
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Gas chromatography coupled with mass spectrometry in selected ion monitoring (GC/MS-SIM) remains a cornerstone technique for trace-level analysis across environmental, pharmaceutical and industrial laboratories. Retention-time locking and automated SIM setup address long-standing challenges in method development, reproducibility and database maintenance. These innovations enhance sensitivity, streamline workflows and ensure reliable, transferable methods even after column maintenance or replacement.
Objectives and Study Overview
This application note presents a systematic strategy for creating robust GC/MS-SIM quantitation methods. The approach integrates optimized chromatographic separation, retention-time locking via Agilent ChemStation, and the AutoSIM macro to automate SIM group generation, exemplified with an 83-compound EPA 8270 scenario.
Methodology and Instrumentation
The workflow consists of four key steps: identifying an optimal GC separation, locking retention times, building an MS quantitation database using full-scan data, and auto-generating SIM acquisition methods. Critical SIM setup parameters include minimum time between peaks, dwell times, group start location and peak broadening factors. Iterative adjustment ensures adequate scans per peak and accommodates complex analyte lists.
Instrumentation
- Agilent 6890 gas chromatograph
- Agilent 5973N mass selective detector
- Agilent ChemStation software (G1701-DA or higher)
Key Results and Discussion
Implementation of retention-time locking produced stable retention windows unaffected by column changes, eliminating the need for frequent database updates. AutoSIM generated SIM methods with as many as 19 SIM groups for 83 analytes after fine-tuning the minimum gap parameter. The combined strategy reduced setup complexity, improved reproducibility and ensured sufficient scan density across peaks.
Benefits and Practical Applications
- Permanent retention times regardless of column maintenance
- Reduced manual effort in updating compound windows
- Easy method transfer between identical instruments
- Enhanced sensitivity and specificity for target analytes
- Scalable to large compound panels in regulatory and QA/QC workflows
Future Trends and Potential Applications
- Expansion to even larger compound libraries and more complex matrices
- Integration with machine learning for predictive retention models
- Application in high-throughput screening and real-time monitoring
- Development of miniaturized GC-MS platforms with retention locking capabilities
Conclusion
The Agilent retention-time locking and AutoSIM features provide a cohesive, automated solution for GC/MS-SIM method development. By standardizing retention times and automating SIM group creation, laboratories can achieve sensitive, reproducible analyses with minimal upkeep, supporting diverse applications from environmental testing to industrial process control.
References
- Giarrocco V, Quimby B, Klee M. Retention Time Locking: Concepts and Applications. Agilent Technologies; Doc. No. 5966-2469E; 2001.
- Prest H, Cormia P. Retention Time Locking: Advantages in GC/MS SIM Analysis. Agilent Technologies Application Brief 23; Doc. No. 5967-2469E; 2001.
- Agnew D, et al. Retention Time Locking with the G1701BA MSD Productivity ChemStation. Agilent Technologies; Doc. No. 5968-3433E; 2001.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD
2006|Agilent Technologies|Applications
Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD Application Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808 USA Abstract The analysis of semivolatiles in drinking water presents challenges due to the required detection limits, desired…
Key words
msd, msdrtl, rtlsemivolatiles, semivolatilessim, siminlet, inlettuning, tuningdftpp, dftpprrf, rrfdrinking, drinkingscan, scanfull, fullrsd, rsdtemperature, temperatureptv, ptvpulse
5973 Inert Performance Electronics: Considerations for GC/MS Methods in Scan and Selective-Ion Monitoring Modes
2004|Agilent Technologies|Technical notes
5973 Inert Performance Electronics: Considerations for GC/MS Methods in Scan and Selected-Ion Monitoring Modes Application Technique/Technology Authors Harry F. Prest, Randy Roushall, Tom Doherty Jim Foote, and James Yano Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara, CA 95051…
Key words
scan, scanwidth, widthparameters, parameterspeak, peaktime, timespeed, speedmsd, msdsim, simmass, massconsiderations, considerationsnumber, numberacquisitions, acquisitionsdwell, dwellover, overautosim
Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics
2004|Agilent Technologies|Technical notes
5973 Inert Performance Electronics: Considerations for GC/MS Methods in Scan and Selected-Ion Monitoring Modes Application Technique/Technology Authors Harry F. Prest, Randy Roushall, Tom Doherty Jim Foote, and James Yano Agilent Technologies, Inc. 5301 Stevens Creek Blvd Santa Clara, CA 95051…
Key words
scan, scanwidth, widthparameters, parameterspeak, peaktime, timespeed, speedmsd, msdsim, simconsiderations, considerationsmass, massnumber, numberacquisitions, acquisitionsdwell, dwellover, overautosim
Parts-per-Trillion Level Calibration of Semivolatiles Using LVI-PTV-GC/MSD
2007|Agilent Technologies|Applications
Parts-per-Trillion Level Calibration of Semivolatiles Using LVI-PTV-GC/MSD Application Environmental Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808 USA Abstract The analysis of semivolatiles in the parts-per-trillion range presents challenges due to analyte activity, background contamination, and…
Key words
ptv, ptvtemp, tempwashes, washessolv, solvvent, ventmsd, msdcryo, cryosemivolatiles, semivolatilesrtl, rtlpurge, purgecalibration, calibrationsim, simdichloromethane, dichloromethaneoven, ovensolvent