Solid Phase Extraction and GC/MS Analysis of Melamine Adulteration in Dairy Products
Applications | 2009 | PerkinElmerInstrumentation
Milk and dairy products can be susceptible to melamine adulteration, posing health risks such as kidney damage upon ingestion. Rapid and reliable detection methods are essential to enforce regulatory standards and safeguard consumer health.
This application note describes modifications to existing GC/MS methods to enable accurate detection of melamine in high-fat and high-sugar dairy matrices. The study aims to optimize sample preparation via solid phase extraction (SPE) and validate method sensitivity, precision, and recovery at regulatory levels.
The modified SPE-GC/MS method achieved detection of melamine below 0.1 µg/mL, exceeding regulatory requirements by 25-fold. A 5 ppb standard yielded an RMS S/N ratio > 25:1. Precision assessed over eight replicate extractions at 1 ppm spiking showed 3.45% RSD. Recovery was approximately 120%, consistent with literature values. These results confirm the method’s sensitivity, reproducibility, and robustness for dairy matrices.
With advances in sample preparation materials and MS detectors, future methods may reduce analysis time and solvent use. Integration with high-resolution MS and automation could further improve throughput and detection limits. Expanding this approach to other contaminants in complex food matrices is a promising direction.
The tailored SPE-GC/MS method provides a reliable and sensitive approach for melamine detection in dairy products. It addresses matrix-related challenges and meets stringent regulatory requirements, making it suitable for routine food safety monitoring.
1. Screening for Melamine Adulteration in Protein-Based Foods by GC/MS, PerkinElmer Application Note.
2. The Extraction and Analysis of Melamine in Milk-Based Products using Discovery DSC-SCX SPE and Ascentis Express HILIC LC-MS/MS, Sigma-Aldrich.
3. GC-MS Method for Screening and Confirmation of Melamine and Related Analogs, FDA LIB 4423, 2007.
GC/MSD, GC/SQ
IndustriesFood & Agriculture
ManufacturerPerkinElmer
Summary
Importance of the Topic
Milk and dairy products can be susceptible to melamine adulteration, posing health risks such as kidney damage upon ingestion. Rapid and reliable detection methods are essential to enforce regulatory standards and safeguard consumer health.
Study Objectives and Overview
This application note describes modifications to existing GC/MS methods to enable accurate detection of melamine in high-fat and high-sugar dairy matrices. The study aims to optimize sample preparation via solid phase extraction (SPE) and validate method sensitivity, precision, and recovery at regulatory levels.
Methodology and Instrumentation
- Sample Preparation:
- Milk samples spiked at 1 µg/mL melamine standard.
- Dilution with phosphate buffer (pH 2.5) and acetonitrile, sonication, and centrifugation.
- Strong cation exchange SPE cleanup using Discovery DSC-SCX cartridges.
- Elution with ammonia in methanol and evaporation to dryness.
- Derivatization with BSTFA + 1% TMCS at 70°C for 45 minutes.
- Gas Chromatography/Mass Spectrometry:
- Instrument: PerkinElmer Clarus 600 GC/MS system (EcoAnalytix Melamine Analyzer).
- Column: Elite-5MS (30 m × 0.25 mm × 0.25 µm).
- Injection: Splitless, 1 µL; inlet temperature 280°C.
- Oven program: 75°C hold 1 min, ramp 15°C/min to 320°C hold 2.7 min.
- MS conditions: Full scan m/z 50–450; source 230°C; solvent delay 6 min.
Main Results and Discussion
The modified SPE-GC/MS method achieved detection of melamine below 0.1 µg/mL, exceeding regulatory requirements by 25-fold. A 5 ppb standard yielded an RMS S/N ratio > 25:1. Precision assessed over eight replicate extractions at 1 ppm spiking showed 3.45% RSD. Recovery was approximately 120%, consistent with literature values. These results confirm the method’s sensitivity, reproducibility, and robustness for dairy matrices.
Benefits and Practical Applications
- High sensitivity allows detection well below regulatory limits.
- Robust SPE cleanup efficiently removes fats and sugars from dairy matrices.
- Derivatization enhances volatility and detection of melamine by GC/MS.
- Applicable for routine QA/QC screening in food safety laboratories.
Future Trends and Applications
With advances in sample preparation materials and MS detectors, future methods may reduce analysis time and solvent use. Integration with high-resolution MS and automation could further improve throughput and detection limits. Expanding this approach to other contaminants in complex food matrices is a promising direction.
Conclusion
The tailored SPE-GC/MS method provides a reliable and sensitive approach for melamine detection in dairy products. It addresses matrix-related challenges and meets stringent regulatory requirements, making it suitable for routine food safety monitoring.
Used Instrumentation
- PerkinElmer Clarus 600 GC/MS (EcoAnalytix Melamine Analyzer).
- Discovery DSC-SCX SPE cartridges (500 mg/6 mL, Sigma-Aldrich).
- Supelco Sylon-BFT derivatization reagent (BSTFA + 1% TMCS).
- Elite-5MS GC column (30 m x 0.25 mm x 0.25 µm).
References
1. Screening for Melamine Adulteration in Protein-Based Foods by GC/MS, PerkinElmer Application Note.
2. The Extraction and Analysis of Melamine in Milk-Based Products using Discovery DSC-SCX SPE and Ascentis Express HILIC LC-MS/MS, Sigma-Aldrich.
3. GC-MS Method for Screening and Confirmation of Melamine and Related Analogs, FDA LIB 4423, 2007.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Milk Adulteration with Melamine – Screening, Testing and Real-Time Detection
2013|PerkinElmer|Others
CASE STUDY Food Fraud Milk Adulteration with Melamine – Screening, Testing and Real-Time Detection The adulteration of protein-based food products with melamine is now a well-known issue. Five years ago, the increasing number of renal failures in dogs and cats…
Key words
melamine, melamineadulteration, adulterationmilk, milkfood, foodprotein, proteinsome, someregulated, regulatedcats, catsdsa, dsaunadulterated, unadulteratedalerted, alertedpoints, pointsreal, realintent, intentcyanuric
Food integrity application compendium
2020|Thermo Fisher Scientific|Guides
TRUST APPLICATION NOTE 10509 your foods are all they should be. Food integrity application compendium Authenticity Adulteration/Food fraud Halal foods Table of contents Introduction 3 General 4-8 Dyes 9 Fish 10 Fruit 11 Vegetables 12 Meat 13-14 Halal foods 15…
Key words
thermo, thermoscientific, scientificirms, irmsadulteration, adulterationbeverages, beveragesmethod, methodoverview, overviewdescription, descriptionauthenticity, authenticityhoney, honeyisolink, isolinkpart, partnumber, numberisotope, isotopedionex
Trace-Level Analysis of Melamine in Milk Products on Agilent 7890A/5975C GC/MSD Using a New Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges
2008|Agilent Technologies|Applications
Trace-Level Analysis of Melamine in Milk Products on Agilent 7890A/5975C GC/MSD Using a New Agilent J&W DB-5ms Ultra Inert Column and SampliQ SCX Cartridges Application Note Gas Chromatography/Mass Spectrometry/Food Safety Authors Abstract Min Cai and Yun Zou A GC/MS method…
Key words
melamine, melaminemilk, milktms, tmssampliq, sampliqabundance, abundancescx, scxtri, trirecovery, recoverymode, modelevel, levellyzed, lyzedreagents, reagentsresin, resintrace, tracecai
Guide to automated sample preparation for GC and GC-MS
2022|Thermo Fisher Scientific|Guides
Table of contents The role of sample preparation in gas chromatography TriPlus RSH robotic sample handling Sampling Workflow Editor software Calibration workflows Derivatization workflows Liquid/liquid extraction workflows Micro-SPE clean-up Guide to automated sample preparation for GC and GC-MS TriPlus RSH…
Key words
derivatization, derivatizationworkflows, workflowsset, setinstrument, instrumentrsh, rshesterification, esterificationtriplus, tripluslle, lleeditor, editorworkflow, workflowrobotic, roboticliquid, liquidstation, stationmicro, micromcpd