Analysis of Polybrominated Biphenyl (PBBs) using GCMS-QP2010

Applications |  | ShimadzuInstrumentation
GC/MSD, GC/SQ
Industries
Environmental
Manufacturer
Shimadzu

Summary

Significance of the Topic


Polybrominated biphenyls (PBBs) are persistent and toxic flame retardants that pose environmental and health risks. Reliable analytical methods are essential for their detection and quantification in environmental, food, and industrial samples.

Objectives and Study Overview


This study demonstrates a sensitive and reproducible gas chromatography–mass spectrometry (GC–MS) method for the separation and quantification of PBB congeners ranging from monobromobiphenyl to decabromobiphenyl using the Shimadzu GCMS-QP2010 system.

Methodology and Instrumentation


The sample introduction employed an autosampler with optimized rinsing protocols and high-speed syringe injection.
Gas chromatography was performed on a DB-5MS column (0.25 mm i.d., 0.1 µm film, 30 m length) with a splitless injection (2 µL) at 350 °C. The oven program ramped from 100 °C to 350 °C at controlled rates to achieve adequate separation.
Mass spectrometry analysis included both full-scan (m/z 45–350) and selected ion monitoring (SIM) modes. Key ions were monitored for each PBB congener to enhance specificity.
Instrumentation:
  • Shimadzu GCMS-QP2010
  • DB-5MS capillary column (30 m × 0.25 mm, 0.1 µm film)

Main Results and Discussion


Calibration curves for all PBB congeners showed linear responses over 0–3500 µg/L, demonstrating strong correlation coefficients. SIM chromatograms at 0.007 µg/L level confirmed high sensitivity. Repeatability studies at 70 µg/L (n=5) yielded coefficients of variation below 6% for most congeners, indicating excellent precision.

Method Benefits and Practical Applications


  • High sensitivity and selectivity through SIM mode for trace-level PBB detection.
  • Robust reproducibility and throughput suitable for routine monitoring in environmental and industrial laboratories.
  • Wide dynamic range facilitating analysis of contaminated samples with varying concentration levels.

Future Trends and Potential Applications


  • Integration with high-resolution mass spectrometry for expanded congener coverage and improved mass accuracy.
  • Development of faster temperature-programmed columns to reduce analysis time.
  • Automation of sample preparation workflows for high-throughput screening.
  • Application to emerging brominated flame retardants and complex matrices.

Conclusion


The GC–MS method using Shimadzu GCMS-QP2010 provides a reliable and precise approach for quantifying PBBs across a broad concentration range. The optimized conditions ensure sensitive detection and reproducible results, supporting environmental and quality-control applications.

References


No references were provided in the original document.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Determination of flame retardants by Gas Chromatography Mass Spectrometry
Determination of flame retardants by Gas Chromatography- Mass Spectrometry AN0035 Application Note RESULTS INTRODUCTION The Restriction of Hazardous Substances Directive (RoHS) regulate hazardous substances found in electrical and electronic equipment. Polybrominated biphenyls (PBBS) and polybrominated diphenyl ethers (PBDEs) are flame…
Key words
scion, scionpolybrominated, polybrominatedpbbs, pbbsflame, flameretardants, retardantsdecabromobiphenyl, decabromobiphenyloctabromobiphenyl, octabromobiphenylconc, conchazardous, hazardousreleased, releasedconlusion, conlusiondecabromodiphenyl, decabromodiphenyldetails, detailssubstances, substancesworking
Analysis of Brominated Flame Retardants and Phthalate Esters Under the Same Conditions Using a Pyrolysis GC-MS System (3) - HBCDD -
LAAN-J-MS-E066 GC-MS Gas Chromatograph Mass Spectrometer Analysis of Brominated Flame Retardants and Phthalate Esters Under the Same Conditions Using a Pyrolysis GC-MS System (3) - HBCDD - 66 In recent years, an analysis method has been required to determine not…
Key words
hbcdd, hbcddsim, simscan, scanmode, modebpbpe, bpbpeevent, eventpentabromophenyl, pentabromophenylfasst, fasstbrominated, brominatedbis, bisretardants, retardantsunder, underethane, ethanepyrolyzer, pyrolyzersame
Analysis of Brominated Flame Retardants and Phthalate Esters Under the Same Conditions Using a Pyrolysis GC-MS System (3) - HBCDD -
LAAN-J-MS-E066 GC-MS Gas Chromatograph Mass Spectrometer Analysis of Brominated Flame Retardants and Phthalate Esters Under the Same Conditions Using a Pyrolysis GC-MS System (3) - HBCDD - 66 In recent years, an analysis method has been required to determine not…
Key words
hbcdd, hbcddsim, simscan, scanmode, modebpbpe, bpbpepentabromophenyl, pentabromophenylevent, eventfasst, fasstbrominated, brominatedbis, bisretardants, retardantsunder, underethane, ethanepyrolyzer, pyrolyzersame
Confirmation and Quantitation of Polybrominated Biphenyls (PBBs) and Polybrominated Diphenyl Ethers (PBDEs) by MS/MS
Application Note: 10042 Confirmation and Quantitation of Polybrominated Biphenyls (PBBs) and Polybrominated Diphenyl Ethers (PBDEs) by MS/MS Thermo Fisher Scientific, Austin, TX, USA Overview Key Words • PolarisQ Ion Trap • Flame Retardants Purpose To investigate the sensitivity and selectivity…
Key words
polybrominated, polybrominateddiphenyl, diphenylpond, pondptv, ptvheptabromobiphenyl, heptabromobiphenylether, etherbiphenyls, biphenylsexcitation, excitationpbdes, pbdespbbs, pbbsbromokal, bromokalpentabromo, pentabromohexabromo, hexabromoions, ionstechnical
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike