Rapid Determination and Quantification of Sensitizers and Skin Irritants in Fragrances by GC-TOFMS
Applications | 2010 | LECOInstrumentation
Fragrances are complex mixtures widely used in cosmetics and personal care products. Among their components, certain synthetic ingredients have been identified as skin sensitizers, respiratory irritants, and possible carcinogens. Rapid and accurate quantification of these hazardous compounds is critical for product safety, regulatory compliance, and consumer protection.
The primary aim of this study was to develop a fast, robust method for simultaneous determination and quantification of known skin sensitizers and irritants in fragrance oils. A common rose oil sample was selected as a representative complex matrix. Calibration curves were established for fourteen target analytes ranging from 200 ppb to 200 ppm, and the method was applied to quantify these compounds in less than five minutes of analysis time.
Sample Preparation and Calibration:
GC-TOFMS Conditions:
TOFMS Conditions:
Calibration performance was excellent with linear response across four orders of magnitude (R2 > 0.99). In the rose oil sample, 11 of the 14 target analytes were quantified, with concentrations from sub-ng/µL to several hundred ng/µL. Two analytes were below detection, and one exceeded the calibration range. High data density enabled spectral deconvolution of coeluting compounds, exemplified by benzyl alcohol masked under a large nonadecane peak, yet accurately identified and quantified using the ChromaTOF algorithm.
• Dramatic reduction of analysis time to under 5 minutes per sample.
• High sensitivity and linearity over broad concentration ranges.
• Automated spectral deconvolution for reliable quantification in complex matrices.
• Applicability to routine quality control and regulatory screening in fragrance and consumer product industries.
Rapid GC-TOFMS methodologies will expand to non-targeted screening workflows, coupling with advanced chemometric tools for comprehensive profiling. Miniaturized and portable TOFMS systems may enable on-site testing. Integration with high-throughput robotics and automated data handling will further enhance laboratory productivity and ensure real-time compliance monitoring.
The described GC-TOFMS approach provides a fast, sensitive, and reliable solution for detecting and quantifying fragrance sensitizers and irritants. Spectral continuity and high acquisition rates enable accurate analysis of coeluting species, improving analytical throughput without compromising data quality.
GC/MSD, GC/TOF
IndustriesOther
ManufacturerAgilent Technologies, LECO
Summary
Importance of the Topic
Fragrances are complex mixtures widely used in cosmetics and personal care products. Among their components, certain synthetic ingredients have been identified as skin sensitizers, respiratory irritants, and possible carcinogens. Rapid and accurate quantification of these hazardous compounds is critical for product safety, regulatory compliance, and consumer protection.
Objectives and Study Overview
The primary aim of this study was to develop a fast, robust method for simultaneous determination and quantification of known skin sensitizers and irritants in fragrance oils. A common rose oil sample was selected as a representative complex matrix. Calibration curves were established for fourteen target analytes ranging from 200 ppb to 200 ppm, and the method was applied to quantify these compounds in less than five minutes of analysis time.
Methodology and Instrumentation
Sample Preparation and Calibration:
- Standards of target compounds were dissolved in ethyl acetate to prepare four-point calibration (200 ppb–200 ppm).
GC-TOFMS Conditions:
- Agilent 6890 GC equipped with DB-WAX column (10 m × 0.18 mm × 0.33 µm).
- Injector at 250 °C, split ratio 10:1.
- Oven program: 40 °C (0.5 min) to 250 °C at 60 °C/min, hold 0.75 min.
- Carrier gas: constant flow of 2.0 ml/min.
- Transfer line at 240 °C.
TOFMS Conditions:
- LECO Pegasus II (EI mode), mass range 35–400 amu, acquisition rate 50 spectra/sec.
- Source temperature 200 °C; total run time 4.75 min.
Main Results and Discussion
Calibration performance was excellent with linear response across four orders of magnitude (R2 > 0.99). In the rose oil sample, 11 of the 14 target analytes were quantified, with concentrations from sub-ng/µL to several hundred ng/µL. Two analytes were below detection, and one exceeded the calibration range. High data density enabled spectral deconvolution of coeluting compounds, exemplified by benzyl alcohol masked under a large nonadecane peak, yet accurately identified and quantified using the ChromaTOF algorithm.
Benefits and Practical Applications of the Method
• Dramatic reduction of analysis time to under 5 minutes per sample.
• High sensitivity and linearity over broad concentration ranges.
• Automated spectral deconvolution for reliable quantification in complex matrices.
• Applicability to routine quality control and regulatory screening in fragrance and consumer product industries.
Future Trends and Potential Applications
Rapid GC-TOFMS methodologies will expand to non-targeted screening workflows, coupling with advanced chemometric tools for comprehensive profiling. Miniaturized and portable TOFMS systems may enable on-site testing. Integration with high-throughput robotics and automated data handling will further enhance laboratory productivity and ensure real-time compliance monitoring.
Conclusion
The described GC-TOFMS approach provides a fast, sensitive, and reliable solution for detecting and quantifying fragrance sensitizers and irritants. Spectral continuity and high acquisition rates enable accurate analysis of coeluting species, improving analytical throughput without compromising data quality.
References
- LECO Corporation. Rapid determination and quantification of sensitizers and skin irritants in fragrances by GC-TOFMS. Saint Joseph, MI, 2010.
- European Information Service Centre. Fragrance publication. Available at http://www.eisc.ca/fragrance-rebut.html.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Potential Allergens in Aromatherapy Oils by GC/MS Using an Agilent J&W DB-XLB Capillary Column
2014|Agilent Technologies|Applications
Potential Allergens in Aromatherapy Oils by GC/MS Using an Agilent J&W DB-XLB Capillary Column Application Note Consumer Products and Flavors and Fragrances Author Abstract Ken Lynam The European Union (EU) regulates 26 flavor and fragrance allergens. Twenty-four of Agilent Technologies,…
Key words
dibromobenzene, dibromobenzeneallergens, allergensbenzyl, benzylfragrance, fragranceallergen, allergencaryophyllene, caryophylleneeucolyptol, eucolyptolaromatherapy, aromatherapylinalool, linaloolmuurolene, muurolenealcohol, alcoholbenzoate, benzoatepinene, pinenecitral, citralcadinene
Detection and Quantification of Fragrance Allergens in Complex Matrices Using GC Orbitrap MS Technology
2019|Thermo Fisher Scientific|Posters
Detection and Quantification of Fragrance Allergens in Complex Matrices Using GC Orbitrap MS Technology Jason Cole1, Richard Law2, and Cristian Cojocariu2 - 1Thermo Fisher Scientific, Runcorn, UK; 2Thermo Fisher Scientific, Austin, USA MATERIALS AND METHODS Purpose: Quantitative analysis of fragrance…
Key words
damascone, damasconebenzyl, benzylallergens, allergenssalicilate, salicilatealcohol, alcoholacetate, acetateisoeugenol, isoeugenolcinnamic, cinnamicamylcinnamic, amylcinnamicaldehyde, aldehydeexactive, exactivebeta, betaalpha, alphaamyl, amyldihydroambrettolide
Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer)
2014|Shimadzu|Posters
PO-CON1469E Analysis of allergens found in cosmetics using MDGC-GCMS (Multi-Dimensional Gas Chromatograph Mass Spectrometer) ASMS 2014 TP761 Sanket Chiplunkar, Prashant Hase, Dheeraj Handique, Ankush Bhone, Durvesh Sawant, Ajit Datar, Jitendra Kelkar, Pratap Rasam Shimadzu Analytical (India) Pvt. Ltd., 1 A/B…
Key words
mdgc, mdgcgcms, gcmsallergens, allergensbenzyl, benzylalcohol, alcoholcosmetics, cosmeticscinnamal, cinnamalisoeugenol, isoeugenolcinnam, cinnamanisyl, anisyldimensional, dimensionalcinnamyl, cinnamylheptine, heptinemulti, multichromatograph
Rapid Screening for Contact Allergens in Perfumes with Pegasus BT GC-TOFMS
2016|Agilent Technologies|Applications
Rapid Screening for Contact Allergens in Perfumes with Pegasus® BT GC-TOFMS LECO Corporation; Saint Joseph, Michigan USA Key Words: Pegasus BT, Target Screening, Non-Target Characterization, Full m/z Range Acquisition, TOFMS, Deconvolution, Calibration, Rapid Analysis Reporting threshold à Figure 1. GC-TOFMS…
Key words
cinnamic, cinnamicbenzyl, benzylpegasus, pegasuscitral, citraltofms, tofmsallergens, allergensalcohol, alcoholcontact, contactleco, lecoyou've, you'veamylcinnamaldehyde, amylcinnamaldehydedelivering, deliveringtarget, targethexylcinnamaldehyde, hexylcinnamaldehydelyral