EPA and EU Phthalates on Rxi®5ms
Applications | | RestekInstrumentation
Phthalate esters are ubiquitous plasticizers found in numerous consumer and industrial products. Due to their potential health and environmental risks, reliable analytical methods are essential for monitoring phthalate levels in environmental, food, and consumer material samples.
This application note presents a rapid and sensitive gas chromatography–mass spectrometry (GC–MS) method for the simultaneous separation and detection of 20 EPA and EU priority phthalate esters. The goal is to demonstrate high-throughput analysis using a short Rxi®-5ms capillary column while maintaining adequate resolution and sensitivity.
The analytical workflow consists of the following elements:
The method achieved baseline separation of 20 phthalate esters within a 5-minute run time. The total ion chromatogram and target ion monitoring (m/z 293 and 307) illustrate distinct peaks for each compound. Key observations include:
This rapid GC–MS protocol offers:
Emerging directions include coupling this fast GC approach with automated sample preparation systems and high-resolution mass spectrometers for enhanced selectivity. Integration with data-processing algorithms and machine learning could further streamline phthalate profiling in complex matrices.
The described GC–MS method on an Rxi®-5ms column provides a fast, reliable, and reproducible platform for simultaneous analysis of 20 priority phthalate esters. Its short run time and robust separation make it well suited for regulatory compliance, environmental monitoring, and quality control.
GC/MSD, GC/SQ, GC columns, Consumables
IndustriesEnvironmental
ManufacturerShimadzu, Restek
Summary
Importance of the topic
Phthalate esters are ubiquitous plasticizers found in numerous consumer and industrial products. Due to their potential health and environmental risks, reliable analytical methods are essential for monitoring phthalate levels in environmental, food, and consumer material samples.
Objectives and study overview
This application note presents a rapid and sensitive gas chromatography–mass spectrometry (GC–MS) method for the simultaneous separation and detection of 20 EPA and EU priority phthalate esters. The goal is to demonstrate high-throughput analysis using a short Rxi®-5ms capillary column while maintaining adequate resolution and sensitivity.
Methodology and instrumentation
The analytical workflow consists of the following elements:
- Column: Rxi®-5ms, 30 m × 0.25 mm ID, 0.25 µm film thickness
- Sample: EPA Method 8061A phthalate mixture (50 µg/mL; benzyl benzoate as internal standard at 80 µg/mL) in methylene chloride
- Injection: 1 µL split (20:1) at 280 °C on a Shimadzu 2010 GC with QP2010+ MS
- Oven program: 200 °C hold 0.5 min, ramp 30 °C/min to 330 °C, hold 1 min
- Carrier gas: Helium at constant linear velocity (66.7 cm/s, 39.5 psi)
- MS conditions: Electron ionization at 70 eV, transfer line 300 °C, source 280 °C, scan range 59–400 amu, solvent delay 0.9 min
Main results and discussion
The method achieved baseline separation of 20 phthalate esters within a 5-minute run time. The total ion chromatogram and target ion monitoring (m/z 293 and 307) illustrate distinct peaks for each compound. Key observations include:
- Resolution of early-eluting dimethyl and diethyl phthalates
- Clear separation of structural isomers (e.g., bis[4-methyl-2-pentyl] phthalate isomers)
- Robust performance across a wide volatility range from dimethyl to diisodecyl phthalate
Benefits and practical applications
This rapid GC–MS protocol offers:
- High throughput analysis for routine environmental and quality assurance laboratories
- Reliable quantitation of trace-level phthalates using a stable internal standard
- Compatibility with regulatory methods (EPA 8061A)
Future trends and potential applications
Emerging directions include coupling this fast GC approach with automated sample preparation systems and high-resolution mass spectrometers for enhanced selectivity. Integration with data-processing algorithms and machine learning could further streamline phthalate profiling in complex matrices.
Conclusion
The described GC–MS method on an Rxi®-5ms column provides a fast, reliable, and reproducible platform for simultaneous analysis of 20 priority phthalate esters. Its short run time and robust separation make it well suited for regulatory compliance, environmental monitoring, and quality control.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Phthalates on Rxi®-XLB (Extended List)
|Shimadzu|Applications
Phthalates on Rxi®-XLB (Extended List) Peaks 1. Dimethyl phthalate 2. Dimethyl isophthalate 3. Diethyl phthalate 4. Benzyl benzoate 5. Diisobutyl phthalate 6. Di-n-butyl phthalate 7. Bis(2-methoxyethyl) phthalate 8. Bis[4-methyl-2-pentyl] phthalate isomer 1 9. Bis[4-methyl-2-pentyl] phthalate isomer 2 10. Bis(2-ethoxyethyl) phthalate…
Key words
rxi, rxixlb, xlbconsultation, consultationscan, scanpeaks, peaksamu, amuphthalates, phthalatesacknowledgement, acknowledgementphthalate, phthalatemethylene, methylenethank, thankscans, scansvent, ventmin, minextended
EPA and EU Phthalates on Rxi®-35Sil MS
|Shimadzu|Applications
EPA and EU Phthalates on Rxi®-35Sil MS Peaks 1. Dimethyl phthalate 2. Diethyl phthalate 3. Benzyl benzoate 4. Diisobutyl phthalate 5. Di-n-butyl phthalate 6. Bis(2-methoxyethyl) phthalate 7. Bis[4-methyl-2-pentyl] phthalate isomer 1 8. Bis[4-methyl-2-pentyl] phthalate isomer 2 9. Bis(2-ethoxyethyl) phthalate 10.…
Key words
consultation, consultationscan, scanpeaks, peaksamu, amuacknowledgement, acknowledgementthank, thankscans, scansvent, ventmin, mintic, ticdelay, delaysec, seclike, likegroup, groupshimadzu
EPA and EU Phthalates on Rxi®-XLB
|Shimadzu|Applications
EPA and EU Phthalates on Rxi®-XLB Peaks 1. Dimethyl phthalate 2. Diethyl phthalate 3. Benzyl benzoate 4. Diisobutyl phthalate 5. Di-n-butyl phthalate 6. Bis(2-methoxyethyl) phthalate 7. Bis[4-methyl-2-pentyl] phthalate isomer 1 8. Bis[4-methyl-2-pentyl] phthalate isomer 2 9. Bis(2-ethoxyethyl) phthalate 10. Di-n-pentyl…
Key words
rxi, rxixlb, xlbconsultation, consultationscan, scanpeaks, peaksamu, amuphthalates, phthalatesacknowledgement, acknowledgementthank, thankscans, scansvent, ventepa, epamin, mintic, ticdelay
EPA and EU Phthalates on Rtx®-440
|Shimadzu|Applications
EPA and EU Phthalates on Rtx®-440 Peaks 1. Dimethyl phthalate 2. Diethyl phthalate 3. Benzyl benzoate 4. Diisobutyl phthalate 5. Di-n-butyl phthalate 6. Bis(2-methoxyethyl) phthalate 7. Bis[4-methyl-2-pentyl] phthalate isomer 1 8. Bis[4-methyl-2-pentyl] phthalate isomer 2 9. Bis(2-ethoxyethyl) phthalate 10. Di-n-pentyl…
Key words