1,4-Dioxane in Drinking Water (5 pg On-Column) on Rxi®-624Sil MS (extracted ion chromatogram)
Applications | | RestekInstrumentation
GC/MSD, GC/SQ
IndustriesEnvironmental
ManufacturerAgilent Technologies, Restek
Key wordsSimilar PDF
A New Solution for Trace-Level Analysis of 1,4-Dioxane in Drinking Water
2012|Agilent Technologies|Applications
A New Solution for Trace-Level Analysis of 1,4-Dioxane in Drinking Water Large Volume Injection in an Unmodified Splitless GC Inlet Set up for Success • Resprep® SPE cartridges assure clean extracts free of matrix interferences. • Restek Premium inlet liner…
Key words
lvsi, lvsicsr, csrrestek, restekrxi, rxisplitless, splitlessleak, leakweldment, weldmentgap, gapinlet, inletunmodified, unmodifieddescription, descriptionbottled, bottleddrinking, drinkinginjection, injectionwater
Lowering Detection Limits for 1,4-Dioxane in Drinking Water Using Large Volume Injection in an Unmodified Splitless GC Inlet
2012|Agilent Technologies|Applications
Environmental Applications Lowering Detection Limits for 1,4-Dioxane in Drinking Water Using Large Volume Injection in an Unmodified Splitless GC Inlet By Chris Rattray, Jack Cochran, and Chris English Abstract Concurrent solvent recondensation–large volume splitless injection (CSR-LVSI) for gas chromatography typically…
Key words
eic, eicmin, minlvsi, lvsicsr, csrpeaks, peaksdrinking, drinkingunmodified, unmodifiedsplitless, splitlessbottled, bottledrecondensation, recondensationwater, watertime, timeconcurrent, concurrentbfb, bfbreagent
EPA 522 Analyte Mix on Rxi®-624Sil MS (30 m x 0.25 mm x 1.4 μm)
|Agilent Technologies|Applications
EPA 522 Analyte Mix on Rxi®-624Sil MS (30 m x 0.25 mm x 1.4 μm) 1. 2. 3. Peaks Tetrahydrofuran-D8 1,4-Dioxane-d8 1,4-Dioxane Column RT (min.) 5.27 6.19 6.23 Sample 1 2 3 Rxi®-624Sil MS, 30 m, 0.25 mm ID,…
Key words
bfb, bfbdichloromethane, dichloromethanedwell, dwellnotes, notessim, simquadrupole, quadrupoleoven, ovenpeaks, peakscarrier, carrierdetector, detectorinstrument, instrumention, ioninjection, injectionmin, mingas
EPA 522 Analyte Mix on Rtx®-624 w/5 m Integra-Guard® (30 m x 0.25 mm x 1.4 μm)
|Agilent Technologies|Applications
EPA 522 Analyte Mix on Rtx®-624 w/5 m Integra-Guard® (30 m x 0.25 mm x 1.4 μm) 1 1. 2. 3. Peaks Tetrahydrofuran-D8 1,4-Dioxane-d8 1,4-Dioxane RT (min.) 5.59 6.51 6.55 2 5.55 5.60 5.65 5.70 5.75 5.80 5.85 5.90…
Key words
bfb, bfbdichloromethane, dichloromethanedwell, dwellnotes, notessim, simquadrupole, quadrupoleoven, ovenpeaks, peakscarrier, carrierdetector, detectorinstrument, instrumention, ioninjection, injectionmin, mingas