Organochlorine Pesticides Fast Analysis Conditions - Rtx®-CLPesticides & Rtx®-CLPesticides2 (dual column analysis)
Applications | | RestekInstrumentation
Organochlorine pesticides are persistent environmental pollutants that pose significant risks to ecosystems and human health. Rapid and reliable analytical methods are essential for routine monitoring, regulatory compliance and quality control in food, soil and water matrices.
This study aimed to establish a fast, dual-column gas chromatography method using electron capture detection (GC-ECD) for the separation and confirmation of 22 common organochlorine pesticide residues. The approach leverages two selectivity-tuned columns to enhance confirmation and minimize false positives.
Sample introduction and chromatographic conditions were optimized to achieve high resolution within a practical runtime. A 1.0 µL splitless injection (0.75 min) introduced a standard mix of target analytes in hexane onto a deactivated guard column. Hydrogen served as the carrier gas under constant pressure, maintaining a linear velocity of 60 cm/s at 300 °C. The oven program ramped from 110 °C (1 min) to 245 °C at 20 °C/min, then to 300 °C at 6 °C/min. Electron capture detection was performed at 310 °C.
Separation of all 22 organochlorine pesticides, including BHC isomers, chlordane congeners, DDT derivatives and endosulfan forms, was achieved with clear baseline resolution. The dual-column setup provided orthogonal selectivity, improving confidence in analyte identification. Total analysis time was approximately 17 minutes.
The described GC-ECD method using a dual-column approach offers a robust, rapid and selective solution for the routine analysis of organochlorine pesticides. It balances speed and resolution, making it well-suited for environmental and food safety laboratories.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerRestek
Summary
Significance of organochlorine pesticide analysis
Organochlorine pesticides are persistent environmental pollutants that pose significant risks to ecosystems and human health. Rapid and reliable analytical methods are essential for routine monitoring, regulatory compliance and quality control in food, soil and water matrices.
Study objectives and overview
This study aimed to establish a fast, dual-column gas chromatography method using electron capture detection (GC-ECD) for the separation and confirmation of 22 common organochlorine pesticide residues. The approach leverages two selectivity-tuned columns to enhance confirmation and minimize false positives.
Methodology
Sample introduction and chromatographic conditions were optimized to achieve high resolution within a practical runtime. A 1.0 µL splitless injection (0.75 min) introduced a standard mix of target analytes in hexane onto a deactivated guard column. Hydrogen served as the carrier gas under constant pressure, maintaining a linear velocity of 60 cm/s at 300 °C. The oven program ramped from 110 °C (1 min) to 245 °C at 20 °C/min, then to 300 °C at 6 °C/min. Electron capture detection was performed at 310 °C.
Used Instrumentation
- Gas chromatograph equipped with ECD
- Analytical columns: Rtx-CLPesticides (30 m × 0.32 mm ID, 0.50 µm) and Rtx-CLPesticides2 (30 m × 0.32 mm ID, 0.25 µm)
- Siltek deactivated guard column (15 cm × 0.32 mm ID)
- Universal angled 'Y' press-tight connector
- 4 mm drilled Uniliner inlet liner
Main results and discussion
Separation of all 22 organochlorine pesticides, including BHC isomers, chlordane congeners, DDT derivatives and endosulfan forms, was achieved with clear baseline resolution. The dual-column setup provided orthogonal selectivity, improving confidence in analyte identification. Total analysis time was approximately 17 minutes.
Benefits and practical application
- Fast and efficient screening of multiple residues in a single run
- Enhanced selectivity and confirmation capability using dual columns
- Simplified sample preparation with splitless injection
- Suitable for routine QA/QC laboratories and regulatory monitoring
Future trends and possibilities
- Integration with mass spectrometry for improved sensitivity and compound confirmation
- Miniaturization and faster temperature programming for high-throughput analysis
- Automation of sample handling and data processing workflows
- Development of greener carrier gases and reduced solvent consumption
Conclusion
The described GC-ECD method using a dual-column approach offers a robust, rapid and selective solution for the routine analysis of organochlorine pesticides. It balances speed and resolution, making it well-suited for environmental and food safety laboratories.
References
- Restek Corporation, Application Note GC_EV00740
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Organochlorine Pesticides US EPA Method 8081 - Rtx®-CLPesticides
|Restek|Applications
Organochlorine Pesticides US EPA Method 8081 Rtx®-CLPesticides Rtx®-CLPesticides2 w/Drilled Uniliner® inlet liner Rtx®-CLPesticides 30m, 0.32mm ID, 0.50µm (cat.# 11139) Rtx®-CLPesticides2 30m, 0.32mm ID, 0.25µm (cat.# 11324) Sample: 20–400µg/mL Organochlorine Pesticide Mix AB #2 (cat.# 32292) in hexane:toluene (1:1) 200µg/mL Pesticide…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorclpesticides, clpesticidesdecachlorobiphenyl, decachlorobiphenylrtx, rtxorganochlorine, organochlorinemethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin, dieldrinaldrin, aldrinketone
Organochlorine Pesticides US EPA Method 8081 - Rtx®-CLPesticides & Rtx®-CLPesticides2 (0.32mm ID)
|Restek|Applications
Organochlorine Pesticides US EPA Method 8081 Rtx®-CLPesticides & Rtx®-CLPesticides2 (0.32mm ID) 19 Rtx®-CLPesticides 30m, 0.32mm ID, 0.50µm (cat.# 11139) 22 19 Rtx®-CLPesticides2 30m, 0.32mm ID, 0.25µm (cat.# 11324) 22 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.…
Key words
bhc, bhchch, hchendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorclpesticides, clpesticidesdecachlorobiphenyl, decachlorobiphenylrtx, rtxorganochlorine, organochlorinelindane, lindanemethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin
Organochlorine Pesticides US EPA Method 8081 - Rtx®-CLPesticides & Rtx®-CLPesticides2 (0.32mm ID)
|Restek|Applications
Organochlorine Pesticides US EPA Method 8081 Rtx®-CLPesticides & Rtx®-CLPesticides2 (0.32mm ID) 19 Rtx®-CLPesticides 30m, 0.32mm ID, 0.50µm (cat.# 11139) 22 19 Rtx®-CLPesticides2 30m, 0.32mm ID, 0.25µm (cat.# 11324) 22 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.…
Key words
bhc, bhchch, hchendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorclpesticides, clpesticidesdecachlorobiphenyl, decachlorobiphenylrtx, rtxorganochlorine, organochlorinelindane, lindanemethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin
Organochlorine Pesticides US EPA Method 8081 - Rtx®-CLPesticides & Rtx®-CLPesticides2 (0.53mm ID)
|Restek|Applications
Organochlorine Pesticides US EPA Method 8081 Rtx®-CLPesticides & Rtx®-CLPesticides2 (0.53mm ID) 19 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 2,4,5,6-tetrachloro-m-xylene α-BHC (α-HCH) γ-BHC (lindane) β-BHC…
Key words
bhc, bhchch, hchendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorclpesticides, clpesticidesdecachlorobiphenyl, decachlorobiphenylrtx, rtxorganochlorine, organochlorinelindane, lindanemethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin