Explosives US EPA Method 8095 - Rtx®-TNT2
Applications | | RestekInstrumentation
Explosive compounds such as nitroaromatics and nitramines pose significant environmental and security risks when released into soil and water. Accurate, sensitive, and rapid analysis of trace levels of these contaminants is critical for environmental monitoring, site remediation, and forensic investigations. US EPA Method 8095 provides standardized guidelines for gas chromatographic determination of these explosives, and the choice of a high-resolution stationary phase can greatly improve analytical performance.
This application note evaluates the performance of the Rtx®-TNT2 GC column for the analysis of explosive residues following US EPA Method 8095. Key objectives include:
The analytical procedure was performed using direct injection of calibration standards and environmental extracts into a gas chromatograph equipped with ECD. Core parameters included:
The Rtx®-TNT2 column achieved full baseline separation of all target analytes within a 13-minute runtime. Notable improvements included:
Detections limits met or exceeded EPA requirements, demonstrating excellent sensitivity and selectivity of the ECD for nitro groups. The optimized temperature program minimized coelution and reduced overall analysis time compared to longer columns.
The method offers several advantages for routine explosives analysis:
Advances likely to further enhance explosive residue analysis include:
The Rtx®-TNT2 GC column, when applied with US EPA Method 8095 and ECD detection, delivers fast, precise, and high-resolution analysis of a broad range of nitroaromatic and nitramine explosives. Its performance supports environmental monitoring, compliance testing, and forensic casework by providing reliable quantification at trace levels.
GC, GC columns, Consumables
IndustriesEnvironmental, Homeland Security
ManufacturerRestek
Summary
Importance of the Topic
Explosive compounds such as nitroaromatics and nitramines pose significant environmental and security risks when released into soil and water. Accurate, sensitive, and rapid analysis of trace levels of these contaminants is critical for environmental monitoring, site remediation, and forensic investigations. US EPA Method 8095 provides standardized guidelines for gas chromatographic determination of these explosives, and the choice of a high-resolution stationary phase can greatly improve analytical performance.
Objectives and Study Overview
This application note evaluates the performance of the Rtx®-TNT2 GC column for the analysis of explosive residues following US EPA Method 8095. Key objectives include:
- Assessing chromatographic resolution of 17 nitroaromatic and nitramine compounds.
- Verifying method suitability for direct injection with an electron capture detector (ECD).
- Optimizing temperature program and flow conditions to achieve rapid analysis.
Methodology and Instrumentation
The analytical procedure was performed using direct injection of calibration standards and environmental extracts into a gas chromatograph equipped with ECD. Core parameters included:
- Column: Rtx®-TNT2, 6 m × 0.53 mm ID, 1.50 µm film thickness.
- Injection: Direct injection via 1 mm Siltek® Uniliner®.
- Temperature Program:
• Initial hold at 80 °C for 1 min
• Ramp at 10 °C/min to 180 °C
• Ramp at 30 °C/min to 300 °C, hold 3 min - Injector temperature: 250 °C; Detector: ECD at 330 °C with anode purge.
- Carrier gas: Helium, 3 psi head pressure (approx. 17 mL/min at 80 °C).
- On-column mass: Approximately 200–1,000 pg per compound using EPA 8095 Mix A and B and 3,4-dinitrotoluene as internal standard.
Main Results and Discussion
The Rtx®-TNT2 column achieved full baseline separation of all target analytes within a 13-minute runtime. Notable improvements included:
- Clear resolution between isomeric dinitrotoluene pairs (2,4-DNT vs. 2,6-DNT).
- Sharp, symmetric peaks for high-boiling explosives like PETN and RDX.
- Reproducible retention times with a dead time of 4.4 sec.
Detections limits met or exceeded EPA requirements, demonstrating excellent sensitivity and selectivity of the ECD for nitro groups. The optimized temperature program minimized coelution and reduced overall analysis time compared to longer columns.
Benefits and Practical Applications
The method offers several advantages for routine explosives analysis:
- Rapid throughput due to short column length and fast temperature ramps.
- High resolution of closely eluting isomers, reducing false positives.
- Robustness for direct injection of environmental samples without extensive cleanup.
- Compatibility with standard EPA calibration mixes and internal standards.
Future Trends and Applications
Advances likely to further enhance explosive residue analysis include:
- Integration of tandem mass spectrometry detectors for compound confirmation.
- Development of even more selective stationary phases targeting modern energetic materials.
- Miniaturized and field-deployable GC systems for on-site screening.
- Automated sample preparation and data processing for high-throughput laboratories.
Conclusion
The Rtx®-TNT2 GC column, when applied with US EPA Method 8095 and ECD detection, delivers fast, precise, and high-resolution analysis of a broad range of nitroaromatic and nitramine explosives. Its performance supports environmental monitoring, compliance testing, and forensic casework by providing reliable quantification at trace levels.
References
- US EPA Method 8095: Determination of Nitroaromatic and Nitramine Explosives by GC/ECD.
- Restek Corporation Application Note: Rtx®-TNT2 Column Specifications and Performance Data.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Explosives US EPA Method 8095 - Rtx®-TNT
|Restek|Applications
Explosives US EPA Method 8095 Rtx®-TNT restek innovation! Rtx®-TNT Improved resolution of nitroaromatic compounds such as those listed in US EPA Method 8095. 9 7 15 11 16 14 8 10 17 6 13 1 5 12 2 34 min.…
Key words
tnt, tntrtx, rtxtrinitrotoluene, trinitrotoluenenitroglycerine, nitroglycerinenitroaromatic, nitroaromaticpetn, petntetryl, tetrylrdx, rdxexplosives, explosivesnitrobenzene, nitrobenzenerestek, restekinnovation, innovationepa, epalisted, listedthose
Explosives - Rtx®-200
|Restek|Applications
Explosives Rtx®-200 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 2-nitrotoluene 3-nitrotoluene 4-nitrotoluene 2,3-diaminotoluene 2,6-diaminotoluene 2,4-diaminotoluene 1,4-dinitrobenzene 2,6-dinitrotoluene 2-amino-6-nitrotoluene 1,3-dinitrobenzene 2,4-dinitrotoluene 2-amino-4-nitrotoluene 2,3-dinitrotoluene 3,4-dinitrotoluene 3-nitrobiphenyl…
Key words
explosives, explosiveshelium
Characterization of Two Wastewaters for Explosives Using On-Column Injection and Gas Chromatography—Time-of-Flight Mass Spectrometry
2008|Agilent Technologies|Applications
® Characterization of Two Wastewaters for Explosives Using On-Column Injection and Gas Chromatography—Time-of-Flight Mass Spectrometry LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, Environmental, Explosives, Deconvolution A better approach is to use a selective column that resolves all Method…
Key words
aminodinitrotoluenes, aminodinitrotoluenestnt, tntrefrigerated, refrigeratedwastewaters, wastewatersaminodinitrotoluene, aminodinitrotoluenewastes, wastesexplosives, explosivesrdx, rdxfrozen, frozendiaminonitrotoluene, diaminonitrotoluenediaminonitrotoluenes, diaminonitrotoluenesdiaminotriazole, diaminotriazoledichlorobenzeneamine, dichlorobenzeneaminemethylthiopyridine, methylthiopyridinenitrobenzenediamine
Semivolatiles on Rtx®-5 with 5 m Integra-Guard® by EPA Method 8270
|Agilent Technologies|Applications
Semivolatiles on Rtx®-5 with 5 m Integra-Guard® by EPA Method 8270 Peaks 31. N-Nitrosomorpholine 32. o-Toluidine 33. Hexachloroethane 34. Nitrobenzene-D5 (SS) 35. Nitrobenzene 36. N-Nitrosopiperidine 37. Isophorone 38. 2-Nitrophenol 39. 2,4-Dimethylphenol 40. Benzoic acid 41. Bis(2-chloroethoxy)methane 42. 2,4-Dichlorophenol 43. Phenyl-tert-butylamine…
Key words
peaks, peaksscan, scanphentermine, phentermineazobenzene, azobenzenediphenylamine, diphenylamineamu, amudichloromethane, dichloromethanescans, scansmin, mindelay, delayinert, inertsec, secgroup, groupstart, starttime