Analysis of volatile organic compounds (VOCs) in water is critical for environmental monitoring, regulatory compliance, and public health protection. The US EPA Method 524.2 provides a standardized approach to quantify trace levels of chlorinated and aromatic VOCs.
This work evaluates the performance of the purge-and-trap GC-MS method for the determination of 60 priority VOCs at 200 ppb in aqueous matrices. The objective is to demonstrate efficient separation, reliable identification, and quantification using Rtx-502.2 stationary phase.
The analytical setup comprises:
The method achieved baseline separation for all target compounds within a 40-minute run time. Critical pairs such as cis-1,2-dichloroethene/1,1-dichloroethane and m-xylene/p-xylene were resolved with resolution factors exceeding 1.5. Mass spectral data provided conclusive identification, and calibration at 200 ppb exhibited linearity (r2 > 0.995) for each analyte.
Advances may include automated sample preparation, multi-dimensional GC for complex matrices, miniaturized field-deployable systems, and integration with machine learning for improved peak deconvolution and data interpretation. Isotopically labeled standards and dynamic reaction cell technologies may further enhance quantitative accuracy.
The US EPA Method 524.2, executed with Rtx®-502.2 column and MS detection, delivers reliable quantification of 60 VOCs in water at trace levels. Its performance meets stringent regulatory requirements and supports environmental and drinking water monitoring programs.
GC/MSD, Purge and Trap, GC columns, Consumables
IndustriesEnvironmental
ManufacturerRestek, Teledyne LABS
Summary
Importance of Topic
Analysis of volatile organic compounds (VOCs) in water is critical for environmental monitoring, regulatory compliance, and public health protection. The US EPA Method 524.2 provides a standardized approach to quantify trace levels of chlorinated and aromatic VOCs.
Study Goals and Overview
This work evaluates the performance of the purge-and-trap GC-MS method for the determination of 60 priority VOCs at 200 ppb in aqueous matrices. The objective is to demonstrate efficient separation, reliable identification, and quantification using Rtx-502.2 stationary phase.
Methodology and Instrumentation
The analytical setup comprises:
- Purge-and-trap system: Tekmar LCS 2000 with Vocarb 4000 trap
- Gas chromatograph: 40 m × 0.18 mm ID × 1.0 µm Rtx®-502.2 capillary column
- Mass spectrometer detector operating in full-scan mode
- Purge: 11 min at 30 mL/min
- Desorption: 250 °C preheat, 2 min, flow rate 30 mL/min
- Oven program: 35 °C hold 4 min; 35→150 °C at 6 °C/min; 150→220 °C at 8 °C/min, hold 8 min
- Injector/detector temperatures: 200 °C/250 °C
- Split ratio: 30:1; carrier linear velocity 21 cm/s at 35 °C
- Analytes: 60 VOCs including halogenated methanes, chlorinated ethanes/ethenes, aromatic hydrocarbons
Main Results and Discussion
The method achieved baseline separation for all target compounds within a 40-minute run time. Critical pairs such as cis-1,2-dichloroethene/1,1-dichloroethane and m-xylene/p-xylene were resolved with resolution factors exceeding 1.5. Mass spectral data provided conclusive identification, and calibration at 200 ppb exhibited linearity (r2 > 0.995) for each analyte.
Benefits and Practical Application
- High sensitivity suitable for regulatory limit enforcement in drinking and environmental waters
- Comprehensive coverage of chlorinated and aromatic VOC classes
- Reproducible retention times and mass spectral confirmation ensure robust QA/QC performance
Future Trends and Opportunities
Advances may include automated sample preparation, multi-dimensional GC for complex matrices, miniaturized field-deployable systems, and integration with machine learning for improved peak deconvolution and data interpretation. Isotopically labeled standards and dynamic reaction cell technologies may further enhance quantitative accuracy.
Conclusion
The US EPA Method 524.2, executed with Rtx®-502.2 column and MS detection, delivers reliable quantification of 60 VOCs in water at trace levels. Its performance meets stringent regulatory requirements and supports environmental and drinking water monitoring programs.
References
- US EPA. Method 524.2: Measurement of Volatile Organic Compounds in Drinking Water by Purge-and-Trap Capillary GC with Mass Spectrometric Detection; 1995.
- Restek Corporation. Application Note GC_EV00010: Performance Evaluation of Rtx®-502.2 Stationary Phase; Bellefonte, PA.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Volatile Organics US EPA Method 502.2 Rtx®-502.2
|Thermo Fisher Scientific|Applications
Volatile Organics US EPA Method 502.2 Rtx®-502.2 for more info A confirmational analysis can be found on www.restek.com/chromatograms Search for chromatogram number GC_EV00006 54/55 69 16 14 17 25 Rtx®-502.2 75m, 0.45mm ID, 2.55µm (cat.# 10986) 14 67 21 42/43…
Key words
butylbenzene, butylbenzenechloride, chloridexylene, xylenebenzene, benzenetert, tertelcd, elcdconfirmational, confirmationalpid, pidfluorobenzene, fluorobenzeneisopropyltoluene, isopropyltolueneinfo, infoallyl, allyldibromomethane, dibromomethanedichlorodifluoromethane, dichlorodifluoromethanebromobenzene
Volatile Organics US EPA Method 524.2 Revision IV - Rtx®-VMS
|Agilent Technologies|Applications
Volatile Organics US EPA Method 524.2 Revision IV Rtx®-VMS GC_EV00718 Purge and Trap Conditions: Concentrator: Tekmar LSC-3100 purge and trap Trap: Vocarb 3000 (type K) Purge: 11 min. @ 40 mL/min. @ ambient temperature. Dry purge: 1 min. @ 40mL/min.…
Key words
butylbenzene, butylbenzenexylene, xylenechloride, chloridemethacrylate, methacrylatemethyl, methylstyrrene, styrrenetert, tertether, etherchloroacetonitrile, chloroacetonitrilesilcosteel, silcosteelmethacrylonitrile, methacrylonitrilepropionitrile, propionitrilevms, vmscarbon, carbonpentachloroethane
Volatile Organics US EPA Method 8021 Rtx®-VRX
|Thermo Fisher Scientific|Applications
Volatile Organics US EPA Method 8021 Rtx®-VRX 39/40 PID • Good choice for waste water analysis. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24.…
Key words
butylbenzene, butylbenzenetert, tertvrx, vrxpid, pidxylene, xylenefluorobenzene, fluorobenzenebenzene, benzenertx, rtxether, etherbutyl, butylelcd, elcdchloride, chloridesilcosteel, silcosteelmethyl, methylisopropyltoluene
Volatile Organics US EPA Method 8260B - Rtx®-VMS
|Agilent Technologies|Applications
Volatile Organics US EPA Method 8260B Rtx®-VMS Reference Standard 8260B Calibration Mix #1* 502.2 Calibration Mix #1 (gases) VOA Calibration Mix #1 (ketones) 8260 Internal Standard Mix 8260 Surrogate Mix 8260 Acetate Mix California Oxygenates Mix Acrolein Mix Ethanol Mix…
Key words
acetate, acetateether, ethertert, tertbutyl, butylmethyl, methylacrolein, acroleinxylene, xylenechloride, chlorideethyl, ethylmix, mixamyl, amylmethacrylate, methacrylatevinyl, vinylcarbon, carbonethanol