General Purpose Intermediate Polarity Capillary GC Columns

Technical notes | 2005 | MerckInstrumentation
GC columns, Consumables
Industries
Manufacturer
Merck

Summary

Importance of Topic


Gas chromatography (GC) remains a cornerstone technique in analytical chemistry for separating and quantifying volatile and semi-volatile compounds. Selecting the appropriate capillary column phase—general purpose or intermediate polarity—is critical for resolving complex mixtures efficiently and cost-effectively. Supelco’s offering of phenyl-containing and cyanopropylphenyl columns addresses diverse retention and selectivity needs in research, quality control, and industrial applications.

Goals and Overview


This document presents Supelco’s general purpose and intermediate polarity capillary columns, emphasizing their chemistry, performance characteristics, and application guidelines. A case study on the Equity-1701 column demonstrates separation of a 59-component industrial solvent mixture, illustrating practical selectivity and efficiency.

Methodology and Instrumentation


Equity-1701 analysis conditions:
  • Column: 30 m × 0.32 mm I.D., 1.0 μm film thickness
  • Oven program: 35 °C hold 8 min, ramp 4 °C/min to 130 °C, hold 2 min
  • Injector: 250 °C, split 200:1, 0.5 μL injection volume, split-cup liner
  • Detector: FID at 250 °C
  • Carrier gas: helium at 25 cm/s constant velocity
  • Sample: neat mixture of 59 common industrial solvents

Main Results and Discussion


The Equity-1701 column (14% cyanopropylphenyl/86% dimethylsiloxane) provided baseline or near-baseline separation for all 59 solvents, demonstrating unique elution order for polar analytes. Compared to phenyl-dimethyl phases (SPB-20, SPB-35, SPB-50), the cyanopropylphenyl phase offered enhanced polarity interactions and confirmation power for chlorinated, oxygenated, and nitro compounds. The 2D plot of retention indices highlighted clusters of structurally related solvents and confirmed the column’s reliability across a broad volatility range.

Benefits and Practical Applications


  • Cost-effective preliminary screening with general purpose columns (SPB-20, SPB-35, SPB-50)
  • Improved resolution of polar and chlorinated compounds on intermediate polarity phases
  • Robust temperature limits (subambient to 280–310 °C) and wide dimensional choices (0.10–0.53 mm I.D.)
  • Quality control in petrochemical, pharmaceutical, environmental, and forensic laboratories

Future Trends and Opportunities


Advances in stationary phase chemistries, including novel mixed-functionality phases and nanostructured coatings, will further enhance selectivity and inertness. Coupling optimized columns with high-throughput autosamplers and multidimensional GC techniques promises deeper profiling of complex matrices. Integration with machine learning for automated method development represents a key frontier.

Conclusion


Supelco’s range of general purpose and intermediate polarity capillary GC columns provides flexible solutions for diverse analytical challenges. The Equity-1701 column exemplifies high selectivity for polar solvents, ensuring reliable identification and quantification. Proper phase selection streamlines method development and enhances data quality across applications.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
General Purpose Non-Polar Capillary GC Columns
595 North Harrison Road Bellefonte, PA 16823-0048 USA Telephone 800-247-6628  814-359-3441 Fax 800-447-3044  814-359-3044 email: [email protected] sigma-aldrich.com/supelco Product Information General Purpose Non-Polar Capillary GC Columns When to Use a General Purpose Column Column Choices Supelco’s general purpose columns…
Key words
acetate, acetatebeta, betapolar, polarcellosolve, cellosolvelength, lengthxylene, xyleneisoamyl, isoamylpurpose, purposenon, nonethyl, ethylbutanol, butanolgeneral, generalikc, ikcformate, formatebutyl
General Purpose Polar Capillary GC Columns
595 North Harrison Road Bellefonte, PA 16823-0048 USA Telephone 800-247-6628  814-359-3441 Fax 800-447-3044  814-359-3044 email: [email protected] sigma-aldrich.com/supelco Product Information General Purpose Polar Capillary GC Columns When to Use a General Purpose Column Column Choices Supelco’s general purpose columns…
Key words
acetate, acetatepurpose, purposesupelco, supelcocellosolve, cellosolvebeta, betageneral, generalxylene, xyleneisoamyl, isoamylethyl, ethylpolar, polarbutanol, butanollength, lengthikb, ikbformate, formatebutyl
Capillary GC Column Choices for Residual Solvent Analyses Using Direct Injection or Solid Phase Microextraction* (SPME)
595 North Harrison Road Bellefonte, PA 16823-0048 USA Telephone 800-247-6628 • 814-359-3441 Fax 800-447-3044 • 814-359-3044 email: [email protected] sigma-aldrich.com/supelco Bulletin 933 Capillary GC Column Choices for Residual Solvent Analyses Using Direct Injection or Solid Phase Microextraction* (SPME) There is a…
Key words
dipole, dipolespme, spmesupelco, supelcoacetate, acetateresidual, residualsolvents, solventsheadspace, headspaceretention, retentionbutanol, butanolidentification, identificationmin, minxylene, xylenetime, timebutyl, butylimmersion
Capillary GC Column Choices for Residual Solvent Analyses Using Direct Injection or Solid Phase Microextraction* (SPME)
595 North Harrison Road Bellefonte, PA 16823-0048 USA Telephone 800-247-6628 • 814-359-3441 Fax 800-447-3044 • 814-359-3044 email: [email protected] sigma-aldrich.com/supelco Bulletin 933 Capillary GC Column Choices for Residual Solvent Analyses Using Direct Injection or Solid Phase Microextraction* (SPME) There is a…
Key words
dipole, dipolespme, spmesupelco, supelcoacetate, acetateresidual, residualsolvents, solventsheadspace, headspaceretention, retentionbutanol, butanolidentification, identificationmin, minxylene, xylenetime, timebutyl, butylimmersion
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike