Environmental Applications
Presentations | | MerckInstrumentation
Gas chromatography and mass spectrometry play a central role in environmental analysis by providing sensitive, selective, and reproducible detection of trace organic pollutants. Compliance with regulatory methods such as USEPA protocols ensures public health protection and accurate monitoring of semivolatiles, pesticides, hydrocarbons, and odorous compounds. High-performance columns and optimized temperature programs deliver excellent peak shape, resolution, and baseline stability across diverse compound classes, from polycyclic aromatic hydrocarbons to chlorinated pesticides and volatile alcohols.
This compilation presents a series of chromatographic methods designed around USEPA Methods 8270, 8081, 8082, 8141, and 8141-MS, as well as custom application notes for diesel fuel, simple hydrocarbons, phthalate esters, indoor air VOCs, mixed alcohols, and trace odors in drinking water. The primary aim is to demonstrate chromatographic performance parameters, analyte coverage, and method reproducibility using a consistent platform of capillary columns and detectors. Representative chromatograms illustrate resolution and retention patterns for each method.
All methods employ capillary GC or GC/MS with splitless or split injections and pressure or constant-flow programming. Sample introduction ranges from direct liquid injection of standards to headspace solid-phase microextraction (SPME) for trace odor compounds. Oven programs start at low initial temperatures (35–120 °C) with fast ramps (5–50 °C/min) to final holds between 250 °C and 325 °C. Detectors include flame ionization (FID) and electron capture (ECD) for organochlorines and phthalates, nitrogen-phosphorus (NPD) for organophosphorus pesticides, and mass spectrometry (MSD) for semivolatiles, PCBs, and indoor air volatiles.
Chromatograms consistently show baseline separation of up to 88 semivolatiles, 22 chlorinated pesticides, Aroclor mixtures, 17 hydrocarbons, 32 mixed alcohols, and a panel of odorants at sub-ppt to ppb levels. Peak shapes remain symmetrical across the run, and detector bleed is minimal, even at high temperatures. SPME-GC/MS in SIM mode achieved clear detection of water odorants (e.g., geosmin, trichloroanisole) at 2 ppt. Method repeatability and resolution are maintained across long runs, illustrating column robustness and reliable response factors for internal standards and surrogates.
Emerging developments include advanced stationary phases for enhanced selectivity of isomers, multidimensional GC×GC to resolve coeluting peaks, and high-resolution mass spectrometry for complex mixtures. Automated headspace SPME and on-line sample preparation will further reduce labor and increase sensitivity. Integration of chemometric data analysis and machine learning can improve peak identification and quantitation in environmental monitoring programs.
This suite of GC and GC/MS methods demonstrates robust, reproducible, and sensitive analyses of a broad spectrum of environmental contaminants. Optimized temperature programs, column selection, and detector configurations ensure excellent peak shape and baseline stability for compliance testing and research applications.
GC columns, Consumables
IndustriesEnvironmental
ManufacturerMerck
Summary
Importance of the Topic
Gas chromatography and mass spectrometry play a central role in environmental analysis by providing sensitive, selective, and reproducible detection of trace organic pollutants. Compliance with regulatory methods such as USEPA protocols ensures public health protection and accurate monitoring of semivolatiles, pesticides, hydrocarbons, and odorous compounds. High-performance columns and optimized temperature programs deliver excellent peak shape, resolution, and baseline stability across diverse compound classes, from polycyclic aromatic hydrocarbons to chlorinated pesticides and volatile alcohols.
Objectives and Overview of the Study
This compilation presents a series of chromatographic methods designed around USEPA Methods 8270, 8081, 8082, 8141, and 8141-MS, as well as custom application notes for diesel fuel, simple hydrocarbons, phthalate esters, indoor air VOCs, mixed alcohols, and trace odors in drinking water. The primary aim is to demonstrate chromatographic performance parameters, analyte coverage, and method reproducibility using a consistent platform of capillary columns and detectors. Representative chromatograms illustrate resolution and retention patterns for each method.
Methodology and Instrumentation
All methods employ capillary GC or GC/MS with splitless or split injections and pressure or constant-flow programming. Sample introduction ranges from direct liquid injection of standards to headspace solid-phase microextraction (SPME) for trace odor compounds. Oven programs start at low initial temperatures (35–120 °C) with fast ramps (5–50 °C/min) to final holds between 250 °C and 325 °C. Detectors include flame ionization (FID) and electron capture (ECD) for organochlorines and phthalates, nitrogen-phosphorus (NPD) for organophosphorus pesticides, and mass spectrometry (MSD) for semivolatiles, PCBs, and indoor air volatiles.
Instrumental Setup
- GC columns: Equity-1, Equity-5, and large-bore Equity-1 (0.25–0.53 mm ID, 0.25–3.0 µm films)
- Detectors: FID at 275–325 °C, ECD at 310 °C, NPD at 320 °C, and MSD scan 33–450 amu with 280–325 °C transfer line
- Injection: splitless and split ratios (10:1 to 200:1), injection ports at 225–280 °C
- Flow control: helium constant flow (1.2 mL/min) or programmed pressure (20–80 psi ramps)
- SPME headspace: DVB/Carboxen/PDMS fiber, 65 °C extraction, 3 min desorption
- Sample loads: 25–100 ng on-column for standards; 25 mL water with NaCl for odor analysis
- Oven programs optimized for each analyte class with holds and ramps ensuring complete elution
Main Results and Discussion
Chromatograms consistently show baseline separation of up to 88 semivolatiles, 22 chlorinated pesticides, Aroclor mixtures, 17 hydrocarbons, 32 mixed alcohols, and a panel of odorants at sub-ppt to ppb levels. Peak shapes remain symmetrical across the run, and detector bleed is minimal, even at high temperatures. SPME-GC/MS in SIM mode achieved clear detection of water odorants (e.g., geosmin, trichloroanisole) at 2 ppt. Method repeatability and resolution are maintained across long runs, illustrating column robustness and reliable response factors for internal standards and surrogates.
Benefits and Practical Applications
- Regulatory compliance: validated according to USEPA guidelines for environmental and drinking water monitoring
- Broad analyte coverage: from light volatiles and alcohols to heavy polycyclics and chlorinated compounds
- High throughput: rapid oven ramps and short analysis times improve sample turnaround
- Low detection limits: SPME and MSD enable trace-level quantitation in challenging matrices
- Flexibility: interchangeable columns and detectors adapt to laboratory needs in QA/QC and research
Future Trends and Possibilities
Emerging developments include advanced stationary phases for enhanced selectivity of isomers, multidimensional GC×GC to resolve coeluting peaks, and high-resolution mass spectrometry for complex mixtures. Automated headspace SPME and on-line sample preparation will further reduce labor and increase sensitivity. Integration of chemometric data analysis and machine learning can improve peak identification and quantitation in environmental monitoring programs.
Conclusion
This suite of GC and GC/MS methods demonstrates robust, reproducible, and sensitive analyses of a broad spectrum of environmental contaminants. Optimized temperature programs, column selection, and detector configurations ensure excellent peak shape and baseline stability for compliance testing and research applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Equity™ Capillary GC Columns
2003|Merck|Brochures and specifications
SUPELCO EQUITY CAPILLARY GC COLUMNS Equity™ Capillary GC Columns The performance you demand... the service you deserve... from the company you trust. Updated with: ● NEW Equity-1701 columns ● New Applications 1 sigma-aldrich.com/supelco SUPELCO EQUITY CAPILLARY GC COLUMNS The performance…
Key words
equity, equitysupelco, supelcocapillary, capillarymin, mincolumns, columnscapseal, capsealexcellent, excellentbullet, bulletresponse, responsebleed, bleedshapes, shapesacetate, acetatemethyl, methylendosulfan, endosulfansupeltex
Phthalate Esters on Equity-5
2003|Merck|Applications
Application Report 16 Author: K. Stenerson Phthalate Esters on Equity-5 Raw Data File Name: C:\data\1\GS100App\frot0055.D (HPCS53) Phthalate esters are frequently listed as suspected endocrine disrupters, and the US EPA has included several on their list of priority pollutants. In this…
Key words
phthalate, phthalatebenzyl, benzylphthtlate, phthtlatediamyl, diamylnonyl, nonyldicyclohexyl, dicyclohexyldiisobutyl, diisobutyldibutyl, dibutylbenzoate, benzoateids, idsoctyl, octylhexyl, hexyldiethyl, diethylbleed, bleedshapes
US EPA Method 8081 Chlorinated Pesticides on Equity-5
2003|Merck|Applications
Application Report 26 Author: J. Walbridge/K. Kiefer Raw Data File Name: US EPA Method 8081 Chlorinated Pesticides on Equity-5 Acquisition System: GC1777 The potential health effects associated with many chlorinated pesticides has led to regulations regarding their use. US EPA…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorids, idsmethoxychlor, methoxychloraldehyde, aldehydeepoxide, epoxidedieldrin, dieldrinaldrin, aldrinketone, ketonesulfate, sulfatewords, wordskey
US EPA Method 8270 Semivolatiles on the Equity-5
2003|Merck|Applications
Application Report 03 Author: K. Stenerson US EPA Method 8270 Semivolatiles on the Equity-5 Raw Data File Name: mar02\0320004.D Acquisition System: 5973 MSD US EPA Method 8270 describes the analysis of a wide variety of semivolatile compounds by GC/MS. In…
Key words
phthalate, phthalatebenzo, benzofluoranthene, fluoranthenepentachlorophenol, pentachlorophenolphenol, phenolanthracene, anthracenepyrene, pyreneshapes, shapesgreat, greatbutylbenzyl, butylbenzylnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazolepeak, peakdibenzofuran, dibenzofuranbenzidine