GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Oxygenates, C1 - C7 - Separation of oxygenated compounds

Applications | 2011 | Agilent TechnologiesInstrumentation
GC, GC columns, Consumables
Industries
Energy & Chemicals
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Efficient separation and quantification of C1–C5 oxygenates in hydrocarbon matrices are critical for fuel quality control, emissions monitoring, and petrochemical research. Trace-level analysis of ethers, aldehydes, alcohols, and ketones supports regulatory compliance and product performance.

Study Objectives and Overview


  • Demonstrate the separation of 20 oxygenated compounds (C1–C5) in a pentane hydrocarbon matrix.
  • Establish a reliable, fast GC method using an Agilent Lowox PLOT column.
  • Achieve baseline resolution in under 45 minutes for routine laboratory screening.

Methodology and Instrumentation


  • Column: Agilent Lowox fused-silica PLOT, 0.53 mm × 10 m (Part no. CP8587).
  • Gas Chromatograph: wide-bore configuration with helium carrier gas at 41 cm/s (15 kPa).
  • Temperature Program: initial oven at 50 °C (5 min), ramp to 270 °C at 30 °C/min.
  • Injection: valve injection with a stack of 10 injections; injector temperature 150 °C.
  • Detection: flame ionization detector at 300 °C.
  • Sample Preparation: oxygenates spiked in pentane at 10–50 ppm.

Main Results and Discussion


  • All 20 target analytes—including diethyl ether, various ethers (e.g., MTBE, ETBE), aldehydes (acetaldehyde to valeraldehyde), alcohols (methanol to 1-butanol), and ketones (acetone, 2-butanone)—were baseline separated within 42 minutes.
  • Distinct retention order reflects volatility and polarity differences; early eluters were light ethers and aldehydes, while heavier alcohols and ketones eluted later.
  • Method reproducibility and sensitivity support detection at low-ppm concentrations.

Benefits and Practical Applications


  • Rapid, high-throughput analysis suitable for QA/QC in fuel and petrochemical laboratories.
  • Trace-level sensitivity allows monitoring of oxygenate additives and potential contaminants.
  • Robust method tolerates hydrocarbon matrices without extensive sample cleanup.

Future Trends and Applications


  • Coupling with mass spectrometry for compound identification and confirmation in complex samples.
  • Development of shorter columns or optimized heating rates to further reduce analysis time.
  • Application to broader matrices, including biofuels and environmental water samples.

Conclusion


The Agilent Lowox PLOT column combined with a wide-bore GC setup delivers rapid, reliable separation of 20 C1–C5 oxygenates in hydrocarbon matrices. This method enhances routine fuel analysis, ensures regulatory compliance, and supports research in energy and fuels applications.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Oxygenates - Separation of oxygenates in a C1-C5 hydrocarbon matrix
Oxygenates Separation of oxygenates in a C1-C5 hydrocarbon matrix Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. For the separation of oxygenates in light hydrocarbons a highly polar stationary phase has to be used. TCEP is used widely…
Key words
ether, etheroxygenates, oxygenatestert, terthydrocarbon, hydrocarbonbutyl, butylhydrocarbons, hydrocarbonslowox, lowoxpropionaldehyde, propionaldehydepropanal, propanaloxygenated, oxygenateddiisopropyl, diisopropylisobutanol, isobutanolsize, sizestreams, streamsadsorbent
Sulfur and oxygenated compounds
Sulfur and oxygenated compounds
2011|Agilent Technologies|Applications
Sulfur and oxygenated compounds Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. Analysis of sulfur and oxygenated compounds on an Agilent Lowox column in 29 minutes. Conditions Technique : GC-capillary Column : Agilent Lowox, 0.53 mm x 10…
Key words
unidentified, unidentifiedsulfur, sulfurcomponent, componentether, etherpropylmercaptane, propylmercaptanetert, tertpropyl, propylbutyraldehyde, butyraldehydeiso, isobutyl, butylethyl, ethylethylmercaptane, ethylmercaptanemethylethylsulfide, methylethylsulfidemethylmercaptane, methylmercaptanemethyl
Solutions for light hydrocarbons and gasses: PLOT columns
Solutions for light hydrocarbons and gasses: PLOT columns
2019|Agilent Technologies|Presentations
Solutions for light hydrocarbons and gasses: PLOT columns 1 April 17, 2019 Separation Superhero Seminar Tour Solutions for Light Hydrocarbons and Gasses: PLOT Columns Allen K. Vickers Agilent Technologies Folsom Technology Center California, USA April 18, 2019 2 Table of…
Key words
superhero, superherotour, tourseminar, seminarseparation, separationplot, plotporous, porousoxygenates, oxygenatesparticle, particlecolumns, columnscolumn, columnalcohol, alcoholalumina, aluminahydrocarbons, hydrocarbonsgas, gasether
Oxygenated compounds, C1 – C12
Oxygenated compounds, C1 – C12
2011|Agilent Technologies|Applications
Oxygenated compounds, C1 – C12 Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. GC separation of 37 oxygenated compounds on a highly selective Agilent Lowox multilayer column is achieved in 45 minutes. Conditions Peak identification Technique : GC/MS…
Key words
fuels, fuelscourtesy, courtesyprinted, printedinjector, injectorusa, usaenergy, energyauthors, authorstechnique, techniquecarrier, carrieridentification, identificationdetector, detectornote, notepeak, peaktemperature, temperaturegas
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike