GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Oxygenated compounds, C1 – C12

Applications | 2011 | Agilent TechnologiesInstrumentation
GC/MSD, GC columns, Consumables
Industries
Energy & Chemicals
Manufacturer
Agilent Technologies

Summary

Importance of the topic


Accurate analysis of oxygenated compounds in the C1–C12 range is critical for energy, environmental and industrial applications. These compounds, including alcohols, aldehydes, ketones and ethers, influence fuel performance, contribute to air pollution and serve as key intermediates in chemical production. A reliable, high-throughput method enables better process control, regulatory compliance and environmental monitoring.

Objectives and study overview


This study presents a robust gas chromatography–mass spectrometry (GC/MS) method for the simultaneous separation and identification of 37 oxygenated compounds. The goal is to demonstrate fast, selective analysis using an Agilent Lowox multilayer column and standard GC/MS instrumentation, achieving baseline resolution within 45 minutes.

Methodology and instrumentation


The method employs a temperature-programmed GC/MS setup optimized for oxygenate analysis. Key parameters are:
  • Column: Agilent Lowox multilayer, 0.53 mm × 10 m fused silica
  • Temperature program: 40 °C initial, ramp at 5 °C/min to 350 °C
  • Carrier gas: Helium at 3.5 mL/min, constant pressure 10 kPa
  • Injector: Split mode
  • Detector: Mass spectrometer
  • Sample load: Approximately 2–5 ng per component

Main results and discussion


The optimized conditions achieved complete separation of all 37 target analytes in under 45 minutes. Peak identification spanned simple alcohols (methanol, ethanol, isopropanol, n-butanol), aldehydes (acetaldehyde, butanal, benzaldehyde) and ketones (acetone, 2-butanone, diisopropylketone), along with ethers and unsaturated carbonyls. The Lowox column’s multilayer stationary phase provided enhanced selectivity for oxygenated species, while MS detection ensured sensitive, unambiguous identification.

Benefits and practical applications


The method offers several advantages:
  • Comprehensive coverage of C1–C12 oxygenates in a single run
  • High selectivity and resolution from the Lowox column
  • Low detection limits (few nanograms) with MS detection
  • Short analysis time suitable for routine quality control
  • Applicability to fuels, petrochemicals, environmental samples and process streams

Conclusion


This application note demonstrates a fast, reliable GC/MS approach for the separation and MS-based identification of a broad suite of oxygenated compounds. The streamlined workflow meets the needs of both research and industrial laboratories requiring precise quantitation and rapid turnaround.

Future trends and possibilities


Emerging directions in oxygenate analysis may include:
  • Coupling with high-resolution or tandem MS for enhanced structural elucidation
  • Two-dimensional GC (GC×GC) to further boost chromatographic resolution
  • Automated sample preparation and data processing for high-throughput screening
  • Application to complex matrices such as biofuels, emissions and ambient air samples
  • Integration of chemometric tools for pattern recognition and source apportionment

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Oxygenates, C1 - C7 - Analysis of oxygenated compounds in botanical air
Oxygenates, C1 - C7 Analysis of oxygenated compounds in botanical air Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. The highly selective Lowox phase generates highest retention for oxygenated compounds. Majority of oxygenated compounds elute after the hydrocarbon…
Key words
oxygenated, oxygenatedlowox, lowoxbotanical, botanicalcourtesy, courtesyfuels, fuelsgenerates, generatesselective, selectivehighest, highestprinted, printedinjector, injectorair, airusa, usaenergy, energyauthors, authorssize
Oxygenates, C1 - C7 - Separation of C1-C7 oxygenated compounds in hydrocarbon matrix
Oxygenates, C1 - C7 Separation of C1-C7 oxygenated compounds in hydrocarbon matrix Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. The highly selective Lowox phase generates highest retention for oxygenated compounds. Majority of oxygenated compounds elute after the…
Key words
lowox, lowoxoxygenated, oxygenatedcourtesy, courtesyfuels, fuelsgenerates, generateshydrocarbon, hydrocarbonselective, selectivehighest, highestprinted, printedinjector, injectorusa, usaenergy, energyauthors, authorshighly, highlytechnique
Aromatic hydrocarbons - Air-toxics analysis in chemical plant
Aromatic hydrocarbons Air-toxics analysis in chemical plant Application Note Environmental Authors Introduction Agilent Technologies, Inc. It is important to have a fast analysis of possible toxic compounds that can be present in a chemical plant. In this application a series…
Key words
xylene, xylenedcpo, dcpodisufide, disufidedicyclopentadiene, dicyclopentadienetoxics, toxicssolvent, solventstyrene, styreneplant, planttoxic, toxicaromatic, aromaticbenzene, benzenetoluene, toluenehydrocarbons, hydrocarbonsprinted, printedinjector
Solutions for light hydrocarbons and gasses: PLOT columns
Solutions for light hydrocarbons and gasses: PLOT columns
2019|Agilent Technologies|Presentations
Solutions for light hydrocarbons and gasses: PLOT columns 1 April 17, 2019 Separation Superhero Seminar Tour Solutions for Light Hydrocarbons and Gasses: PLOT Columns Allen K. Vickers Agilent Technologies Folsom Technology Center California, USA April 18, 2019 2 Table of…
Key words
superhero, superherotour, tourseminar, seminarseparation, separationplot, plotporous, porousoxygenates, oxygenatesparticle, particlecolumns, columnscolumn, columnalcohol, alcoholalumina, aluminahydrocarbons, hydrocarbonsgas, gasether
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike