Agilent CrossLab - Supplies for Former Varian GC Systems
Posters | 2012 | Agilent TechnologiesInstrumentation
In gas chromatography, inert sample flow paths are essential to preserving analyte integrity and ensuring reliable detection of trace‐level compounds. Inlet liners, O-rings, ferrules, and related consumables can introduce active sites that adsorb or degrade analytes, reducing sensitivity, distorting peak shapes, and increasing maintenance. Agilent CrossLab Ultra Inert liners and accessories address these challenges by providing highly deactivated surfaces and optimized materials to maximize transfer efficiency and reproducibility.
The primary aim of the document is to introduce the Ultra Inert product line for former Varian GC systems, demonstrating compatibility, performance improvements, and practical benefits. It catalogs inlet liners, O-rings, column ferrules, septa, syringes, and other supplies, comparing original and Ultra Inert deactivations and highlighting superior performance metrics.
Performance evaluation involved repetitive injections of challenging compounds (e.g., endrin) using splitless single‐taper liners packed with wool and detectors such as electron capture detection (ECD). Comparative tests measured analyte breakdown and peak shape stability over more than 100 injections. Key instrumentation included:
Ultra Inert liners consistently delivered:
Agilent CrossLab Ultra Inert consumables offer:
As GC applications evolve toward ultra-trace analysis and high-throughput workflows, future developments may include:
Agilent CrossLab Ultra Inert liners and associated GC consumables provide a comprehensive solution for minimizing analyte loss, enhancing sensitivity, and extending maintenance intervals in gas chromatographic analyses. Their compatibility with legacy Varian systems and modern Agilent instruments ensures seamless adoption and reproducible results across diverse applications.
No external references were cited in the source document.
Consumables
IndustriesManufacturerAgilent Technologies
Summary
Significance of the topic
In gas chromatography, inert sample flow paths are essential to preserving analyte integrity and ensuring reliable detection of trace‐level compounds. Inlet liners, O-rings, ferrules, and related consumables can introduce active sites that adsorb or degrade analytes, reducing sensitivity, distorting peak shapes, and increasing maintenance. Agilent CrossLab Ultra Inert liners and accessories address these challenges by providing highly deactivated surfaces and optimized materials to maximize transfer efficiency and reproducibility.
Objectives and Overview
The primary aim of the document is to introduce the Ultra Inert product line for former Varian GC systems, demonstrating compatibility, performance improvements, and practical benefits. It catalogs inlet liners, O-rings, column ferrules, septa, syringes, and other supplies, comparing original and Ultra Inert deactivations and highlighting superior performance metrics.
Methodology and Used Instrumentation
Performance evaluation involved repetitive injections of challenging compounds (e.g., endrin) using splitless single‐taper liners packed with wool and detectors such as electron capture detection (ECD). Comparative tests measured analyte breakdown and peak shape stability over more than 100 injections. Key instrumentation included:
- Former Varian CP8400, CP8410, CP9010, CP9050, 8035, 8100, 8200 GC systems
- Agilent CrossLab Ultra Inert inlet liners and graphitized seals
- 60% Vespel/40% graphite and pure graphite ferrules
- Non-stick bleed and temperature-optimized septa
- Fixed and removable autosampler syringes
Main Results and Discussion
Ultra Inert liners consistently delivered:
- Enhanced deactivation coverage, minimizing active sites that trap analytes
- Improved peak shapes for highly active forensic and environmental compounds
- Lower detection limits (e.g., endrin detection at 100 ppb with minimal breakdown)
- Extended liner lifetime with stable performance after 100+ injections
- Reduced preventive maintenance owing to less contamination and carry-over
Benefits and Practical Applications
Agilent CrossLab Ultra Inert consumables offer:
- Plug-and-play compatibility with former Varian and current Agilent GC interfaces
- Touchless packaging to maintain cleanliness and simplify installation
- Certificates of Performance for traceability and compliance
- Wide portfolio covering inlet liners (split, splitless, direct, SPME), ferrules, septa, syringes, and column nuts
- Risk-free 90-day guarantee ensuring user confidence
Future Trends and Possibilities
As GC applications evolve toward ultra-trace analysis and high-throughput workflows, future developments may include:
- Advanced surface chemistries for even lower analyte adsorption
- Smart consumables with lot-specific digital performance data
- Broader compatibility with emerging GC–MS and GC×GC architectures
- Sustainable materials to reduce environmental impact
- Integrated consumable monitoring and predictive maintenance through IoT connectivity
Conclusion
Agilent CrossLab Ultra Inert liners and associated GC consumables provide a comprehensive solution for minimizing analyte loss, enhancing sensitivity, and extending maintenance intervals in gas chromatographic analyses. Their compatibility with legacy Varian systems and modern Agilent instruments ensures seamless adoption and reproducible results across diverse applications.
Reference
No external references were cited in the source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent GC AND GC/MS - Catalog Consumables and Spare Parts
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
supplies, suppliesagilent, agilentparts, partscrosslab, crosslabdescription, descriptionoem, oemnut, nutinlet, inletliners, linerssepta, septacolumn, columnferrule, ferruleneedle, needlestick, stickassembly
Accessories for Varian® GC Instruments
2015|Merck|Brochures and specifications
Accessories for Varian® GC Instruments Liners Ferrules Septa Syringes Vials Gas Purification Accessories for Varian®/Bruker GC Instruments Liners for 1177 Split/Splitless Injector Ports Product Description Split Liners Straight-through I.D. O.D. Length (mm) (mm) (mm) Unit Varian® Agilent® Part Number Part…
Key words
ptfe, ptfesilicone, siliconepurifier, purifierseptum, septumline, linecaps, capsvarian, varianunpacked, unpackedfocusliner, focuslinerpurifiers, purifiersglass, glassliners, linersclear, clearrubber, rubberpart
GC AND GC/MS - Your Essential Resource for Columns & Supplies
2016|Agilent Technologies|Brochures and specifications
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2014 Printed in Canada October XX, 2014 5991-5213EN GC AND GC/MS Your Essential…
Key words
agilent, agilentsupplies, suppliescolumns, columnslength, lengthparts, partscrosslab, crosslabcolumn, columnfilm, filmsuggested, suggesteddescription, descriptionrinsable, rinsableoem, oemultimetal, ultimetaltips, tipsnut
Operating Hints for Using Split/Splitless Injectors
2002|Restek|Guides
Technical Guide 1 Operating Hints for Using Split/Splitless Injectors Inside: Overviews of split and splitless injection techniques Backpressure-regulated injection systems Headpressure-regulated injection systems Operating in the split injection mode Inlet liners for split injections Operating in the splitless injection Mode…
Key words
siltek, siltekliners, linersuniliner, unilinersplit, splitdeactivation, deactivationliner, linersplitless, splitlessinjection, injectionsplitter, splitterwool, woolinlet, inletgcs, gcsfeaturing, featuringport, porttight