HIGH-THROUGHPUT VOC AND INORGANIC GAS ANALYSIS: AUTOMATED SIFT-MS
Technical notes | | AnatuneInstrumentation
Selected ion flow tube mass spectrometry (SIFT-MS) has emerged as a transformative technique for real-time, direct analysis of volatile organic compounds (VOCs) and inorganic gases down to parts-per-trillion levels. Its ability to bypass chromatographic separation offers rapid turnaround and comprehensive profiling, making it invaluable across environmental monitoring, pharmaceutical quality control, food safety, and fragrance research.
The article aims to demonstrate how integrating SIFT-MS with automated sampling systems maximizes throughput, consistency, and analytical depth. It reviews static and dynamic headspace methods, multiple headspace extraction, and direct gas analysis, illustrating their application in diverse matrices such as polymers, soils, consumer products, and sampling canisters.
SIFT-MS operates by reacting eight controlled reagent ions (H3O+, NO+, O2+, O–, O2–, OH–, NO2–, NO3–) with target analytes in an ion–molecule reactor, followed by mass spectrometric detection. No derivatization or preconcentration is required for trace-level detection.
Used Instrumentation:
1. High-Throughput Static Headspace Analysis (SHA):
2. Continuous Headspace Analysis (CHA):
3. Multiple Headspace Extraction (MHE):
4. Direct Bag and Canister Analysis:
Automated SIFT-MS unlocks the full potential of direct mass spectrometric gas analysis by combining ultrafast detection, high sensitivity, and robust automation. It offers a versatile solution for high-throughput VOC and inorganic gas quantitation across diverse applications, driving efficiency and insight in analytical laboratories.
HeadSpace, SIFT-MS
IndustriesManufacturerGERSTEL, Syft Technologies
Summary
Importance of the Topic
Selected ion flow tube mass spectrometry (SIFT-MS) has emerged as a transformative technique for real-time, direct analysis of volatile organic compounds (VOCs) and inorganic gases down to parts-per-trillion levels. Its ability to bypass chromatographic separation offers rapid turnaround and comprehensive profiling, making it invaluable across environmental monitoring, pharmaceutical quality control, food safety, and fragrance research.
Objectives and Overview of the Article
The article aims to demonstrate how integrating SIFT-MS with automated sampling systems maximizes throughput, consistency, and analytical depth. It reviews static and dynamic headspace methods, multiple headspace extraction, and direct gas analysis, illustrating their application in diverse matrices such as polymers, soils, consumer products, and sampling canisters.
Methodology and Used Instrumentation
SIFT-MS operates by reacting eight controlled reagent ions (H3O+, NO+, O2+, O–, O2–, OH–, NO2–, NO3–) with target analytes in an ion–molecule reactor, followed by mass spectrometric detection. No derivatization or preconcentration is required for trace-level detection.
Used Instrumentation:
- Voice200ultra SIFT-MS system (Syft Technologies)
- GERSTEL Multipurpose Sampler (MPS) autosampler (Linthicum, Md.)
Main Results and Discussion
1. High-Throughput Static Headspace Analysis (SHA):
- Rapid screening of residual monomers in polymers, including direct formaldehyde quantitation from polyoxymethylene within seconds.
- Applications in pharmaceutical packaging, food safety, and sensory quality control.
2. Continuous Headspace Analysis (CHA):
- Real-time monitoring of dynamic processes, illustrated by four-hour tracking of fragrance release from a topical cream.
- Enables 24/7 automated collection of time-resolved VOC profiles for product development and QA.
3. Multiple Headspace Extraction (MHE):
- Overcomes slow equilibrium kinetics in solids (e.g., soil or polystyrene) by sequential headspace sampling to calculate total VOC content.
- Transforms MHE into a routine, rapid method for residual solvent analysis in packaging materials and thermally labile samples.
4. Direct Bag and Canister Analysis:
- High-throughput evaluation of gas sampling devices without drying or derivatization.
- Applications include occupational safety, ambient air monitoring, indoor air quality, and process gas screening.
Benefits and Practical Applications
- Unparalleled sample throughput (dozens per hour) reduces cost and speeds decision-making.
- Comprehensive analysis of challenging analytes (ammonia, formaldehyde, sulfur compounds) without pretreatment.
- Enhanced reproducibility and reduced operator error via automation.
- Wide linear dynamic range suitable for prescreening and detailed analysis in R&D and QA/QC labs.
Future Trends and Applications
- Integration with robotic sample handling for fully unattended 24/7 operation.
- Expansion into field-deployable platforms for in situ environmental monitoring.
- Coupling with data-analysis software for automated anomaly detection and predictive modeling.
- Adoption in regulated industries for compliance monitoring and rapid screening workflows.
Conclusion
Automated SIFT-MS unlocks the full potential of direct mass spectrometric gas analysis by combining ultrafast detection, high sensitivity, and robust automation. It offers a versatile solution for high-throughput VOC and inorganic gas quantitation across diverse applications, driving efficiency and insight in analytical laboratories.
References
- Smith D.; Spanel P. Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis. Mass Spectrom. Rev. 2005, 24, 661–700.
- Prince B.J.; Milligan D.B.; et al. Applications of selected ion flow tube mass spectrometry to real-time atmospheric monitoring. Rapid Commun. Mass Spectrom. 2010, 24, 343–356.
- Langford V.S.; Graves I.; et al. Rapid monitoring of volatile organic compounds: a comparison between gas chromatography/mass spectrometry and selected ion flow tube mass spectrometry. Rapid Commun. Mass Spectrom. 2014, 28, 10–18.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
HIGH-SPEED FORMALDEHYDE ANALYSIS FOR THE PROCESS-LINE AND LABORATORY: SIFT-MS
|GERSTEL|Applications
AS201 Wellbrook Court | Girton Road | Cambridge | CB3 0NA | | tel: +44 (0) 1223 279210 | fax: +44 (0) 1223 279253 [email protected] | anatune.co.uk HIGH-SPEED FORMALDEHYDE ANALYSIS FOR THE PROCESS-LINE AND LABORATORY: SIFT-MS V.S. Langford,1 M. Perkins,2…
Key words
formaldehyde, formaldehydesift, siftheadspace, headspacemonomer, monomerconcentration, concentrationfrom, frommhe, mhemass, masstechnique, techniquetube, tubedifferent, differentresidual, residualgas, gashigh, highinjection
HIGH-THROUGHPUT RESIDUAL SOLVENT AND RESIDUAL MONOMER ANALYSIS USING SELECTED ION FLOW TUBE MASS SPECTROMETRY
|GERSTEL|Applications
AS208 Wellbrook Court | Girton Road | Cambridge | CB3 0NA | | tel: +44 (0) 1223 279210 | fax: +44 (0) 1223 279253 | email: [email protected] | anatune.co.uk HIGH-THROUGHPUT RESIDUAL SOLVENT AND RESIDUAL MONOMER ANALYSIS USING SELECTED ION FLOW…
Key words
headspace, headspaceppmv, ppmvformaldehyde, formaldehydemonomer, monomerresidual, residualmhe, mhesift, siftanalysis, analysismarkedly, markedlymultiple, multiplepackaging, packagingconcentration, concentrationsolvents, solventsopportunities, opportunitiestechnique
AUTOMATION APPLICATIONS - SYFT TECHNOLOGIES
2017|Syft Technologies|Brochures and specifications
AUTOMATION APPLICATIONS SYFT TECHNOLOGIES AUTOMATION APPLICATIONS OF SIFT-MS Automation has been widely utilized by traditional chromatographic techniques for many years, enabling instrumentation to be productive 24/7 – a critical consideration because sample throughput is typically only 20 to 60 samples…
Key words
sift, siftsyft, syftheadspace, headspaceanalysis, analysisvocs, vocsautomation, automationmhe, mhereagent, reagenttrillion, trillionsha, shavery, veryapplications, applicationsresidual, residualrapid, rapidgases
RAPID DETERMINATION OF VOLATILE COMPOUND CONTENT USING MULTIPLE HEADSPACE EXTRACTION-SIFT-MS
|GERSTEL|Applications
AS218 Wellbrook Court | Girton Road | Cambridge | CB3 0NA | | tel: +44 (0) 1223 279210 | fax: +44 (0) 1223 279253 | email: [email protected] | anatune.co.uk PAPERBOARD APPLICATION NOTE SERIES/ 2 RAPID DETERMINATION OF VOLATILE COMPOUND CONTENT…
Key words
sift, siftmhe, mheheadspace, headspacevolatile, volatilepaperboard, paperboardconcentration, concentrationvolatility, volatilityrsds, rsdsdetermination, determinationfour, fourrapid, rapidstatic, statictrace, tracecompounds, compoundsconcentrations