Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS
Brochures and specifications | | SCION InstrumentsInstrumentation
The analysis of semi-volatile organic compounds in complex environmental matrices is essential for regulatory compliance, environmental protection, and public health. USEPA Method 8270 is widely used but often challenged by the need for low detection limits, rapid sample throughput, and comprehensive identification of unknowns. A sensitive, robust, and user-friendly GC/MS solution addresses these demands effectively.
This study evaluates a mixed scan approach combining full scan and selected ion monitoring (SIM) on the Bruker Scion SQ single quadrupole GC/MS for USEPA Method 8270. The objectives were to demonstrate sub-ppm detection, simplified method setup, and consistent performance across a broad analyte list and challenging sample extracts.
The Bruker Scion SQ GC/MS with mixed scan acquisition and Compound Based Scanning offers a comprehensive solution for USEPA Method 8270. It delivers sub-ppm sensitivity in full scan, robust SIM quantitation, and streamlined method management. Integrated QA/QC and reporting tools further enhance laboratory productivity and regulatory compliance, making this approach well suited for modern environmental testing laboratories.
GC/MSD, GC/SQ
IndustriesEnvironmental
ManufacturerSCION Instruments
Summary
Significance of the Topic
The analysis of semi-volatile organic compounds in complex environmental matrices is essential for regulatory compliance, environmental protection, and public health. USEPA Method 8270 is widely used but often challenged by the need for low detection limits, rapid sample throughput, and comprehensive identification of unknowns. A sensitive, robust, and user-friendly GC/MS solution addresses these demands effectively.
Goals and Study Overview
This study evaluates a mixed scan approach combining full scan and selected ion monitoring (SIM) on the Bruker Scion SQ single quadrupole GC/MS for USEPA Method 8270. The objectives were to demonstrate sub-ppm detection, simplified method setup, and consistent performance across a broad analyte list and challenging sample extracts.
Methodology and Instrumentation
- Gas chromatograph: BR-5ms column (30 m × 0.25 mm × 0.25 µm), constant flow 1.0 mL/min
- Injector: Scion Split/Splitless with pulsed split injection (1:50 split at 250 C)
- Oven program: 45 C hold 3 min, ramp 30 C/min to 120 C hold 1 min, ramp 10 C/min to 310 C hold 5 min
- Mass spectrometer: Scion SQ with inert ion source and advanced ion optics
- Acquisition: Mixed scan mode (full scan 45–450 amu at 200 ms, plus SIM for 57 compounds) using Compound Based Scanning (CBS)
- Calibration: Standards from 0.075 to 30 ppm, internal standards at 40 ppm
Main Results and Discussion
- Full scan detection of target compounds down to 75 ppb, exceeding method sensitivity requirements
- Linear calibration curves (correlation > 0.998) across 0.075–30 ppm, including challenging analytes like pyridine
- CBS auto-optimized SIM segments ensuring at least 10 data points per peak without manual segment management
- Robust performance over 17 sludge extract injections with internal standard recovery deviations within 5–24 percent
- Built-in DFTPP tune-to-target pass/fail reports and SPCC RRF values exceeding USEPA criteria
- Automated QA/QC reporting via EnviroPro Access templates for regulatory compliance
Benefits and Practical Applications
- Achieves lower detection limits for environmental monitoring and risk assessment
- Simplifies method setup and updates for extensive compound lists through CBS
- Enables simultaneous full scan for library searching and SIM for sensitive quantitation
- Enhances throughput and reduces maintenance by employing pulsed split injection
- Delivers automated, standardized reporting to meet USEPA quality control guidelines
Future Trends and Opportunities
- Expansion of compound libraries and automated identification using machine learning
- Higher speed and resolution mass analyzers for improved mixed mode coverage
- Integration of real-time monitoring and inline sample preparation workflows
- Advanced data analytics and cloud-based reporting for remote laboratory management
- Development of portable GC/MS platforms for field deployable environmental analysis
Conclusion
The Bruker Scion SQ GC/MS with mixed scan acquisition and Compound Based Scanning offers a comprehensive solution for USEPA Method 8270. It delivers sub-ppm sensitivity in full scan, robust SIM quantitation, and streamlined method management. Integrated QA/QC and reporting tools further enhance laboratory productivity and regulatory compliance, making this approach well suited for modern environmental testing laboratories.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Performance of EPA Method 8270 using Hydrogen Carrier Gas on SCION GC MS
|SCION Instruments|Applications
Performance of EPA Method 8270 using Hydrogen Carrier Gas on SCION GC-MS Application Note AN0018 INTRODUCTION United States Environmental Protection Agency (USEPA) Method 8270 is an analytical method for the detection of semi-volatile organic compounds in solid waste matrices, soils,…
Key words
scion, scionbenzo, benzopyrene, pyrenehydrogen, hydrogendichloromethane, dichloromethaneminimise, minimiserobust, robustanalyser, analyserpropylamine, propylaminenitroso, nitrosopentachlorophenol, pentachlorophenolcarrier, carrierperylene, peryleneion, ionsource
Performance of Method 8270 Using Hydrogen Carrier Gas
2015|SCION Instruments|Applications
Your local gas generation partner Performance of Method 8270 Using Hydrogen Carrier Gas www.peakscientific.com Performance of Method 8270 Using Hydrogen Carrier Gas Introduction USEPA Method 8270 [1] for semivolatiles is used by laboratories to measure a mixture of acids, bases,…
Key words
pass, passscion, scionhydrogen, hydrogengas, gassplit, splitspcc, spcccheck, checkinjection, injectioncompounds, compoundscarrier, carrierpulsed, pulsedsludge, sludgeenviropro, enviroprocalibration, calibrationhexachlorocyclopentadiene
C1 to C10 Ethyl Esters
|Quadrex|Applications
Your local gas generation partner Performance of Method 8270 Using Hydrogen Carrier Gas www.peakscientific.com Performance of Method 8270 Using Hydrogen Carrier Gas Introduction USEPA Method 8270 [1] for semivolatiles is used by laboratories to measure a mixture of acids, bases,…
Key words
pass, passscion, scionhydrogen, hydrogengas, gassplit, splitspcc, spcccheck, checkinjection, injectioncompounds, compoundscarrier, carrierpulsed, pulsedsludge, sludgeenviropro, enviroprocalibration, calibrationhexachlorocyclopentadiene
Determination of Class I USP Residual Solvents and TICs in Dietary Supplements and Pharmaceutical Products by GC/MS
2011|Bruker|Applications
Residual Solvent Analysis Application Notes #283030 Determination of Class I USP Residual Solvents and TICs in Dietary Supplements and Pharmaceutical Products by GC/MS Residual solvents in pharmaceuticals are defined as organic volatile chemicals that are consumed or produced in the…
Key words
residual, residualsolvents, solventshazard, hazardenv, envtoxic, toxiccompounds, compoundstics, ticsscion, scioncompound, compoundtemp, tempscan, scanset, setbruker, brukeranalysed, analysedtetrachloride