Analysis of volatile compounds is essential in multiple industries including environmental monitoring, food and beverage quality, and pharmaceutical testing. Static headspace sampling coupled to gas chromatography offers a robust approach to isolate and quantify volatiles while minimizing matrix interference. Advances in autosampler technology address key challenges such as sample throughput, repeatability, and carryover control.
The study describes the design and capabilities of the Thermo Scientific TriPlus 500 Gas Chromatography Headspace Autosampler. It aims to deliver reliable, high-throughput performance by combining precise pressure control, efficient heating, and modular sample handling. The system supports seamless integration with the TRACE 1300 GC and Chromeleon CDS, ensuring streamlined compliance and data management.
Key methodological features include:
Performance metrics demonstrate typical area repeatability below 0.8% RSD under standard conditions. The precise temperature control and direct GC interface reduce sample carryover and downtime. Automated leak checks and real-time system diagnostics improve operational reliability. Compact design saves approximately 30% bench space compared to competing setups while delivering some of the highest throughput rates available.
Further integration of autosamplers with digital laboratory networks and remote diagnostics is expected to improve data transparency and maintenance efficiency. Advancements in microfluidics and inline sample preparation might extend headspace techniques to lower sample volumes and broader analyte ranges. Sustainable designs focusing on energy and gas savings will gain prominence as laboratories pursue greener operations.
The Thermo Scientific TriPlus 500 HS autosampler offers a comprehensive solution for headspace GC analysis, combining high precision, robust operation, and flexible capacity. Its modular architecture, advanced control features, and software integration make it a valuable asset for high-throughput and regulated analytical environments.
HeadSpace
IndustriesManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
Analysis of volatile compounds is essential in multiple industries including environmental monitoring, food and beverage quality, and pharmaceutical testing. Static headspace sampling coupled to gas chromatography offers a robust approach to isolate and quantify volatiles while minimizing matrix interference. Advances in autosampler technology address key challenges such as sample throughput, repeatability, and carryover control.
Objectives and Overview
The study describes the design and capabilities of the Thermo Scientific TriPlus 500 Gas Chromatography Headspace Autosampler. It aims to deliver reliable, high-throughput performance by combining precise pressure control, efficient heating, and modular sample handling. The system supports seamless integration with the TRACE 1300 GC and Chromeleon CDS, ensuring streamlined compliance and data management.
Methodology and Instrumentation
Key methodological features include:
- Pneumatic control of vial and sampling loop pressure for consistent injection volumes and repeatability
- Efficient heating of the entire sample path (ambient +5 to 300 °C) to prevent condensation of high-boiling solvents
- Multi-level purging across five flow rates to minimize carryover
- Sample overlapping up to 12 vials to maximize instrument utilization
- Flexible injection modes including standard single extraction, multiple headspace extraction (up to 100 passes), and multiple headspace injection
Main Results and Discussion
Performance metrics demonstrate typical area repeatability below 0.8% RSD under standard conditions. The precise temperature control and direct GC interface reduce sample carryover and downtime. Automated leak checks and real-time system diagnostics improve operational reliability. Compact design saves approximately 30% bench space compared to competing setups while delivering some of the highest throughput rates available.
Benefits and Practical Applications
- Enhanced analytical precision and repeatability for regulated environments
- Continuous 24/7 operation with minimal maintenance and low downtime
- Reduced gas consumption through optimized purging protocols
- Scalable vial capacity tailored to laboratory throughput needs
- Full compliance with major safety and electromagnetic compatibility directives
Future Trends and Opportunities
Further integration of autosamplers with digital laboratory networks and remote diagnostics is expected to improve data transparency and maintenance efficiency. Advancements in microfluidics and inline sample preparation might extend headspace techniques to lower sample volumes and broader analyte ranges. Sustainable designs focusing on energy and gas savings will gain prominence as laboratories pursue greener operations.
Conclusion
The Thermo Scientific TriPlus 500 HS autosampler offers a comprehensive solution for headspace GC analysis, combining high precision, robust operation, and flexible capacity. Its modular architecture, advanced control features, and software integration make it a valuable asset for high-throughput and regulated analytical environments.
Used Instrumentation
- TriPlus 500 Gas Chromatography Headspace Autosampler (12-vial carousel, valve-and-loop design)
- TRACE 1300 Series Gas Chromatograph
- Chromeleon Chromatography Data System
- Optional modules: robotic vial loader, interchangeable 40-vial trays, recirculating chiller, barcode reader
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 7697A GC Headspace Sampler - Data Sheet
2019|Agilent Technologies|Brochures and specifications
Data Sheet Agilent 7697A GC Headspace Sampler Overview The Agilent 7697A headspace sampler is part of Agilent’s line of gas chromatography products. Based on the architecture of the market-leading GC and 7693A ALS line of products, the 7697A has been…
Key words
vial, vialheadspace, headspacesettable, settableincrements, incrementspressurization, pressurizationcontrol, controlsampling, samplingsample, samplepressure, pressureuser, useroptional, optionalparameters, parametersepc, epcmenu, menuvia
Boost Productivity with Reliable GC Sampling Solutions
2019|Thermo Fisher Scientific|Presentations
Boost Productivity with Reliable GC Sampling Solutions Daniela Cavagnino Product Marketing Manager GC and Autosamplers The world leader in serving science Thermo Scientific GC Sampling Systems Thermo Scientific™ TriPlus™ 500 Headspace Autosampler Thermo Scientific™ TriPlus™ RSH™ Autosampler Sample Throughput Thermo…
Key words
vial, vialsample, sampleincubation, incubationloop, looprsh, rshheadspace, headspacebest, bestcarryover, carryovertriplus, triplusvortex, vortexinjection, injectionderivatization, derivatizationspme, spmeitex, itexunattended
Agilent 8697 Headspace Sampler - Data Sheet
2023|Agilent Technologies|Brochures and specifications
Data Sheet Agilent 8697 Headspace Samplers Overview Agilent 8697-XL tray and 8697 are the next generation of best-in-class headspace samplers from Agilent. Based on the industry-leading 8890 GC and 7697A headspace sampler, these headspace samplers have been designed to deliver…
Key words
vial, vialfill, fillheadspace, headspacepressure, pressuresettable, settabletemperature, temperatureequilibration, equilibrationsequence, sequencecontrol, controlflow, flowloop, loopmenu, menupressurization, pressurizationtime, timesampling
Productivity from all angles - Thermo Scientific TriPlus 500 Gas Chromatography Headspace Autosampler
2019|Thermo Fisher Scientific|Brochures and specifications
Productivity from all angles Thermo Scientific TriPlus 500 Gas Chromatography Headspace Autosampler Superior repeatability. Easy method transfer. High data quality. Powered by an innovative new design, the Thermo Scientific™ TriPlus™ 500 GC Headspace Autosampler delivers more of what you want,…
Key words
chromeleon, chromeleonheadspace, headspacethermo, thermoscientific, scientificcds, cdsqualification, qualificationloop, loopsample, samplevial, vialdesign, designtime, timeperformance, performancecompliance, complianceyour, yourbarcode