Agilent MassHunter Workstation Software – 7250 Accurate-Mass Quadrupole Time of Flight GC/MS - Familiarization Guide

Manuals | 2017 | Agilent TechnologiesInstrumentation
GC/MSD, GC/MS/MS, GC/HRMS, GC/Q-TOF
Industries
Manufacturer
Agilent Technologies

Summary

Importance of the Topic



Accurate-mass quadrupole time-of-flight gas chromatography–mass spectrometry (Q-TOF GC/MS) has become an indispensable tool in analytical chemistry for high-resolution compound identification. Its combination of chromatographic separation with accurate mass measurement enables confident qualitative analysis across complex sample matrices, supporting environmental monitoring, pharmaceutical research, food safety, and forensic investigations.

Objectives and Study Overview



This guide demonstrates the development and application of an optimized acquisition and data-processing workflow on the Agilent 7250 Q-TOF GC/MS system. Key objectives include:
  • Establishing instrument setup and calibration routines to maximize sensitivity and mass accuracy.
  • Defining GC and MS acquisition parameters for routine screening of target compounds.
  • Illustrating data analysis workflows in MassHunter Qualitative Navigator and Qualitative Workflows.
  • Demonstrating unknown screening using SureMass deconvolution.

Methodology and Instrumentation



System preparation begins with verifying software installation (MassHunter Acquisition, Qualitative, Quantitative), GC configuration (Agilent 7890 with split/splitless inlet, 10 µL ALS syringe), and performance checks on the 7250 Q-TOF. A J&W DB-35ms column (30 m × 0.25 mm, 0.25 µm) was conditioned, and gas flows set (He carrier, N₂ collision cell).

  • Mass Calibration and Tuning: Daily TOF calibration using internal reference ions (20–650 m/z, 1 Hz acquisition rate) to maintain <1 ppm mass accuracy.
  • GC Method: Oven program from 80 °C (3 min) to 250 °C at 25 °C/min; split ratio 200:1; 1.1 mL/min constant He flow; transfer line at 280 °C.
  • MS Acquisition: Electron impact ionization at 70 eV; solvent delay 5 min; acquisition range 40–600 m/z at 5 spectra/s; both profile and centroid data saved; data and storage thresholds applied to reduce file size.

Used Instrumentation



  • Agilent 7250 Accurate-Mass Q-TOF GC/MS
  • Agilent 7890 GC with split/splitless inlet and automatic liquid sampler (10 µL ALS syringe)
  • J&W DB-35ms capillary column (30 m × 0.25 mm, 0.25 µm)
  • MassHunter Workstation Software (Acquisition, Qualitative Navigator, Qualitative Workflows, Unknowns Analysis)

Key Results and Discussion



Using a standard mixture (dodecane, biphenyl, 4-chlorobiphenyl, methyl palmitate), the workflow enabled:
  • Accurate retention times and mass spectra matching library entries within <5 ppm tolerance.
  • Efficient peak picking and background subtraction in Qualitative Navigator.
  • Automated compound screening via Find by Fragments workflow, generating target reports in PDF format.
  • Unknown compound deconvolution with SureMass, successfully differentiating coeluting signals and matching library spectra for non-target screening.

Benefits and Practical Applications



This approach ensures reproducible sensitivity, rapid turn-around for routine QC/QA analyses, and robust identification in complex matrices. Automated mass calibration scheduling and integrated reporting streamline high-throughput laboratory operations.

Conclusion



The described methodology on the Agilent 7250 Q-TOF GC/MS provides a comprehensive, user-friendly workflow from instrument setup to advanced qualitative data analysis. It achieves high mass accuracy, reliable compound identification, and flexible reporting to meet diverse analytical needs.

Future Trends and Potential Applications



Continued integration of machine-learning algorithms for spectral deconvolution, expansion of accurate-mass libraries, and cloud-based data sharing will further enhance throughput and reproducibility. Coupling Q-TOF GC/MS with online sample preparation, ambient ionization sources, and ion mobility separation represents promising frontiers for next-generation qualitative analyses.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent MassHunter Workstation Software – 7200 Accurate-Mass Quadrupole Time of Flight GC/MS - Familiarization Guide
Agilent MassHunter Workstation Software – 7200 Accurate-Mass Quadrupole Time of Flight GC/MS Familiarization Guide Before you begin 3 Prepare your system 3 Prepare the samples required for data acquisition 4 Exercise – Develop an acquisition method for the 7200 5…
Key words
exercise, exerciseselect, selectcomments, commentsicon, iconinstructions, instructionsdata, datatab, tabdetailed, detailedsteps, stepsanalyze, analyzeclick, clickdialog, dialogfile, filewindow, windowmass
Agilent MassHunter Workstation Software – Data Acquisition for 7000 Series Triple Quad GC/MS - Familiarization Guide
Agilent MassHunter Workstation Software – Data Acquisition for 7000 Series Triple Quad GC/MS Familiarization Guide Before you begin 3 Prepare your system 3 Prepare the samples required for data acquisition 3 Exercise – Develop an acquisition method for the 7000…
Key words
comments, commentsselect, selectclick, clickinstructions, instructionsexercise, exercisesteps, stepsmethod, methoddetailed, detailedcreate, createdata, dataicon, iconsave, savefile, filequantitative, quantitativesequence
MassHunter Profinder Software - Quick Start Guide
MassHunter Profinder Software - Quick Start Guide
2017|Agilent Technologies|Manuals
MassHunter Profinder Software Quick Start Guide For Research Use Only. Not for use in diagnostic procedures. Getting Started 11 User Interface 12 Basic Profinder Workflow 22 Add sample files to your project 24 Align chromatograms 28 Edit and run your…
Key words
profinder, profinderfeature, featureisotopologue, isotopologueguide, guideextraction, extractionquick, quickstart, startyour, yourclick, clickbatch, batchworkflow, workflowproject, projectrecursive, recursiveyou, youfile
Agilent MassHunter Mass Profiler Software - Familiarization Guide
MassHunter Mass Profiler Software Familiarization Guide Process Data 2 Create a project 3 Edit a method 6 Perform a PCA analysis 13 Apply a different method 18 Edit a project 18 View Results 20 View results in the Feature Table…
Key words
profiler, profilerfamiliarization, familiarizationfeature, featureproject, projectguide, guidefeatures, featuresexercises, exercisesmass, masstable, tableclick, clickview, viewparameters, parameterspca, pcareprocesses, reprocessesexport
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike