Comprehensive GC System Based on Flow Modulation for the 7890A GC
Technical notes | 2008 | Agilent TechnologiesInstrumentation
Comprehensive two-dimensional gas chromatography (GC×GC) expands the resolving power beyond conventional one-dimensional GC, enabling detailed analysis of highly complex mixtures encountered in petrochemical, environmental, and flavor/fragrance applications.
This application brief presents a hardware solution for flow-based modulation on an Agilent 7890A GC system, aiming to simplify GC×GC operation by avoiding cryogenic cooling and reducing system complexity while maintaining high peak capacity.
GC×GC employs two capillary columns of differing polarities arranged in series, separated by a flow modulator. The modulator cycles through collect and inject phases, cutting effluent from the primary column into narrow bands via flow compression, then transferring them to the secondary column for fast separation. Agilent’s Capillary Flow Technology uses a low-mass stainless steel modulator and a three-way solenoid valve controlled by an Electronic Pneumatics Control module, eliminating cryogen dependence. Critical parameters include differential flow ratios (typically 20:1 between second and first column), modulation period, and detector speed (≥50 Hz).
Example analyses demonstrate clear separation of fatty acid methyl esters in biodiesel, aromatic class resolution in gasoline samples, and volatile constituents in lime oil. Flow modulation achieved comparable second-dimension peak widths to thermal approaches with typical modulation cycles of 1.40 s load and 0.10 s inject. Comparison to cryogenic thermal modulation highlights benefits: no cryogen consumption, simplified hardware, and run times similar to 1D GC. The system delivers peak capacity increases without extended analysis durations.
Adaptation of flow-modulated GC×GC to coupling with mass spectrometry, integration with high-throughput data processing and machine learning, expansion to more challenging matrices, and potential miniaturization for field-deployable systems represent promising directions.
The Agilent 7890A flow modulation approach offers a practical, cost-effective GC×GC solution by replacing cryogenic thermal modulators with a low-mass flow-based device. It simplifies instrument operation while delivering enhanced peak resolution and throughput for complex sample analyses.
GC, GCxGC
IndustriesManufacturerAgilent Technologies
Summary
Significance of the Topic
Comprehensive two-dimensional gas chromatography (GC×GC) expands the resolving power beyond conventional one-dimensional GC, enabling detailed analysis of highly complex mixtures encountered in petrochemical, environmental, and flavor/fragrance applications.
Objectives and Study Overview
This application brief presents a hardware solution for flow-based modulation on an Agilent 7890A GC system, aiming to simplify GC×GC operation by avoiding cryogenic cooling and reducing system complexity while maintaining high peak capacity.
Methodology and Instrumentation
GC×GC employs two capillary columns of differing polarities arranged in series, separated by a flow modulator. The modulator cycles through collect and inject phases, cutting effluent from the primary column into narrow bands via flow compression, then transferring them to the secondary column for fast separation. Agilent’s Capillary Flow Technology uses a low-mass stainless steel modulator and a three-way solenoid valve controlled by an Electronic Pneumatics Control module, eliminating cryogen dependence. Critical parameters include differential flow ratios (typically 20:1 between second and first column), modulation period, and detector speed (≥50 Hz).
Instrumental Setup
- Agilent 7890A GC with Capillary Flow Technology modulator and firmware ≥A.04.06
- Flame ionization detector (FID) at ≥200 Hz or other fast detector
- Split/splitless inlet
- Pneumatics Control Module (PCM) and three-way micro valve
- Primary column: e.g., 30 m×0.25 mm×0.25 µm DB-5ms
- Secondary column: e.g., 5 m×0.25 mm×0.15 µm INNOWax
- Data system: Agilent GC ChemStation or equivalent software with 2D processing
Main Results and Discussion
Example analyses demonstrate clear separation of fatty acid methyl esters in biodiesel, aromatic class resolution in gasoline samples, and volatile constituents in lime oil. Flow modulation achieved comparable second-dimension peak widths to thermal approaches with typical modulation cycles of 1.40 s load and 0.10 s inject. Comparison to cryogenic thermal modulation highlights benefits: no cryogen consumption, simplified hardware, and run times similar to 1D GC. The system delivers peak capacity increases without extended analysis durations.
Benefits and Practical Applications
- Elimination of cryogenic gases reduces operational cost
- Simplified setup and maintenance via robust flow modulator design
- Rapid two-dimensional separation compatible with existing GC infrastructure
- Improved peak capacity benefits petrochemical profiling, environmental monitoring, and flavor/fragrance authentication
Future Trends and Applications
Adaptation of flow-modulated GC×GC to coupling with mass spectrometry, integration with high-throughput data processing and machine learning, expansion to more challenging matrices, and potential miniaturization for field-deployable systems represent promising directions.
Conclusion
The Agilent 7890A flow modulation approach offers a practical, cost-effective GC×GC solution by replacing cryogenic thermal modulators with a low-mass flow-based device. It simplifies instrument operation while delivering enhanced peak resolution and throughput for complex sample analyses.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Capillary Flow Technology: GCxGC Flow Modulator
2013|Agilent Technologies|Brochures and specifications
Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES Maximize information while collecting and analyzing GC data Comprehensive two-dimensional GC, or GCxGC, is a powerful technique that can be used to separate very complex…
Key words
modulator, modulatorflow, flowgcxgc, gcxgcsecond, secondtechnology, technologycapillary, capillarychannel, channelaromatics, aromaticsmodulation, modulationagilent, agilentcollection, collectionfeedstock, feedstockpcm, pcminlet, inletmixtures
Integration and Optimization of Hardware and Software for a Differential Flow Modulated GCxGC
2007|Agilent Technologies|Presentations
Paper 170-2 Integration and Optimization of Hardware and Software for a Differential Flow Modulated GCxGC Roger Firor, James McCurry, Chunxiao Wang and Michael Feeney Agilent Technologies Wilmington, DE USA Dalin Conference Page 1 June, 2007 Basic Configuration The configuration Split/splitless…
Key words
modulation, modulationmodulator, modulatorflow, flowvalve, valvefid, fiddirection, directionmodulated, modulatedpcm, pcminlet, inletinject, injectchannel, channelsplitless, splitlesscollection, collectioncollect, collectsplit
Comprehensive Flow Modulated Two-Dimensional Gas Chromatography System
2007|Agilent Technologies|Technical notes
Comprehensive Flow Modulated Two-Dimensional Gas Chromatography System Application Brief Roger L. Firor Two-dimensional GC (GC x GC), a relatively new gas chromatographic technique, is being recognized for its powerful separation capabilities for the analysis of complex mixtures. The methodology involves…
Key words
aromatics, aromaticsmodulation, modulationvalve, valveflow, flowalkanes, alkanesmodulator, modulatormono, monoagilent, agilentdirection, directionburdens, burdenscpm, cpmchannel, channelnaphthalenes, naphthalenessuccessively, successivelyfifth
Using a Dual LTM Series II System with Flow Modulated Comprehensive GCxGC
2011|Agilent Technologies|Technical notes
Using a Dual LTM Series II System with Flow Modulated Comprehensive GCxGC Application Note Application Area Identifier Author Abstract Roger L Firor A comprehensive GCxGC system based on differential flow modulation is described Agilent Technologies, Inc. that uses three independent…
Key words
ltm, ltmgcxgc, gcxgcmodulator, modulatorcft, cftmodulation, modulationflow, flowdimension, dimensionmodulated, modulatedinject, injectcomprehensive, comprehensiveperiod, periodgaps, gapschannel, channelsystem, systemcolumn