A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis
Applications | 2010 | Agilent TechnologiesInstrumentation
The accurate and rapid measurement of organochlorine pesticides in environmental and remediation samples is crucial for contract laboratories to maintain throughput, cost-efficiency, and regulatory compliance. High-efficiency capillary columns with small internal diameters can significantly enhance analysis speed and sensitivity by reducing bleed, improving peak shapes, and enabling short run times.
This study conducts a direct performance comparison between two sets of 0.18 mm internal diameter columns for rapid Contract Laboratory Program (CLP) pesticide analysis: Agilent J&W High Efficiency GC columns (DB-17ms for primary analysis and DB-XLB for confirmation) versus proprietary columns from Vendor R. The goal is to assess chromatographic resolution, analysis speed, baseline stability, and overall suitability for CLP methods under hydrogen carrier gas and flow programming conditions.
Standard CLP pesticide mixtures were prepared at low target levels (3.2 ng/mL) and injected (0.5 µL) via split/splitless mode with a 5 m deactivated retention gap connected through a Y-splitter to two analytical columns. Hydrogen was used as carrier gas with flow programming to achieve sub-6 min separations. Chromatographic parameters were established via Agilent Method Translation software and further optimized for Vendor R columns. Peak resolution, tailing, and detector baseline drift were evaluated under consistent conditions for fair comparison.
Agilent’s DB-17ms column resolved all 22 CLP target pesticides in under 6 min with sharp, symmetrical peaks and minimal baseline drift, outperforming Vendor R’s primary column which resolved 20 of 22 compounds and exhibited peak tailing. For confirmation, Agilent DB-XLB achieved near-baseline separation of 20 peaks with stable baselines, whereas Vendor R’s confirmatory column, although resolving all 22 analytes, showed significant bleed and temperature-dependent drift. Attempts to optimize Vendor R conditions partially improved resolution but remained inferior to Agilent columns.
High-efficiency 0.18 mm columns enable rapid CLP pesticide screening with improved sensitivity and lower detection limits. Stable baselines simplify integration, reduce reanalysis rates, and increase sample throughput. These columns are versatile for other fast GC applications beyond CLP protocols.
Emerging developments include ultra-high-speed GC, novel stationary phases for enhanced selectivity, microfluidic and multidimensional GC workflows, and integration with mass spectrometry and advanced data analytics. Continued miniaturization and green carrier gases will further improve efficiency and environmental footprint.
The head-to-head comparison demonstrates that Agilent J&W High Efficiency 0.18 mm columns deliver superior chromatographic performance, faster analysis times, and more stable baselines for CLP pesticide methods compared to Vendor R offerings, making them the preferred choice for high-throughput contract laboratories.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Significance of the Topic
The accurate and rapid measurement of organochlorine pesticides in environmental and remediation samples is crucial for contract laboratories to maintain throughput, cost-efficiency, and regulatory compliance. High-efficiency capillary columns with small internal diameters can significantly enhance analysis speed and sensitivity by reducing bleed, improving peak shapes, and enabling short run times.
Objectives and Study Overview
This study conducts a direct performance comparison between two sets of 0.18 mm internal diameter columns for rapid Contract Laboratory Program (CLP) pesticide analysis: Agilent J&W High Efficiency GC columns (DB-17ms for primary analysis and DB-XLB for confirmation) versus proprietary columns from Vendor R. The goal is to assess chromatographic resolution, analysis speed, baseline stability, and overall suitability for CLP methods under hydrogen carrier gas and flow programming conditions.
Methodology
Standard CLP pesticide mixtures were prepared at low target levels (3.2 ng/mL) and injected (0.5 µL) via split/splitless mode with a 5 m deactivated retention gap connected through a Y-splitter to two analytical columns. Hydrogen was used as carrier gas with flow programming to achieve sub-6 min separations. Chromatographic parameters were established via Agilent Method Translation software and further optimized for Vendor R columns. Peak resolution, tailing, and detector baseline drift were evaluated under consistent conditions for fair comparison.
Instrumentation Used
- Agilent 6890N Gas Chromatograph
- Agilent 7683B Autosampler
- Dual µECD detectors (320 °C)
- DB-17ms, 20 m × 0.18 mm × 0.18 µm column (Agilent)
- DB-XLB, 20 m × 0.18 mm × 0.18 µm column (Agilent)
- Vendor R proprietary columns (20 m × 0.18 mm × 0.18 µm and 20 m × 0.18 mm × 0.14 µm)
- 5 m × 0.25 mm retention gap
Results and Discussion
Agilent’s DB-17ms column resolved all 22 CLP target pesticides in under 6 min with sharp, symmetrical peaks and minimal baseline drift, outperforming Vendor R’s primary column which resolved 20 of 22 compounds and exhibited peak tailing. For confirmation, Agilent DB-XLB achieved near-baseline separation of 20 peaks with stable baselines, whereas Vendor R’s confirmatory column, although resolving all 22 analytes, showed significant bleed and temperature-dependent drift. Attempts to optimize Vendor R conditions partially improved resolution but remained inferior to Agilent columns.
Practical Benefits and Applications
High-efficiency 0.18 mm columns enable rapid CLP pesticide screening with improved sensitivity and lower detection limits. Stable baselines simplify integration, reduce reanalysis rates, and increase sample throughput. These columns are versatile for other fast GC applications beyond CLP protocols.
Future Trends and Potential Uses
Emerging developments include ultra-high-speed GC, novel stationary phases for enhanced selectivity, microfluidic and multidimensional GC workflows, and integration with mass spectrometry and advanced data analytics. Continued miniaturization and green carrier gases will further improve efficiency and environmental footprint.
Conclusion
The head-to-head comparison demonstrates that Agilent J&W High Efficiency 0.18 mm columns deliver superior chromatographic performance, faster analysis times, and more stable baselines for CLP pesticide methods compared to Vendor R offerings, making them the preferred choice for high-throughput contract laboratories.
References
- Chang I.L., Klee M.S., Murphy J. Validation Analysis of EPA CLP Target Organochlorine Pesticides with the Agilent 6890 Series GC and Micro-ECD. Agilent Tech. Publ. 5966-3742E (1998).
- George C. Rapid Analysis of CLP Pesticides Using High-Temperature DB-35ms and DB-XLB Columns. Agilent Tech. Publ. 5988-4973EN (2001).
- Wool L., Decker D. Practical Fast Gas Chromatography for Contract Laboratory Program Pesticide Analysis. J. Chromatogr. Sci. 40 (2002).
- Lynam K., Long W. CLP Pesticide Analysis with 0.18 mm ID High Efficiency GC Columns Utilizing Helium Carrier Gas. Agilent Tech. Publ. 5989-7818EN (2008).
- Lynam K. Agilent J&W High-Efficiency Capillary Columns: Productivity-Enhancing Tools for Fast GC Applications. Agilent Tech. Publ. 5989-7499EN (2007).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
A 0.32 mm ID Capillary Column Approach to Contract Laboratory Program (CLP) Pesticides Analysis
2010|Agilent Technologies|Applications
A 0.32 mm ID Capillary Column Approach to Contract Laboratory Program (CLP) Pesticides Analysis Application Note Environmental Authors Abstract Doris Smith and Ken Lynam Trace level organochlorine pesticide testing is a high volume critical analysis in the Agilent Technologies, Inc.…
Key words
bhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordaneheptachlor, heptachlorclp, clpdecachlorobiphenyl, decachlorobiphenylmethoxychlor, methoxychlorxlb, xlbaldehyde, aldehydeepoxide, epoxidedieldrin, dieldrinaldrin, aldrinketone, ketonetetrachloro
Contract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas
2010|Agilent Technologies|Applications
Contract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas Application Environmental Authors Ken Lynam and William Long Agilent Technologies, Inc. 2850 Centerville Road Wilmington, Delaware 19808 U.S.A. Abstract Contract Laboratory Program (CLP)…
Key words
translated, translatedcarrier, carrieroriginal, originalsealant, sealanttranslation, translationclp, clpmethod, methodtriplet, tripletsplitter, splittercolumns, columnsbhc, bhctranslate, translatehydrogen, hydrogenhelium, heliumset
Rapid Contract Laboratory Program (CLP) Pesticides Analysis with 0.32 mm ID Capillary GC Columns Utilizing Hydrogen Carrier Gas
2009|Agilent Technologies|Applications
Rapid Contract Laboratory Program (CLP) Pesticides Analysis with 0.32 mm ID Capillary GC Columns Utilizing Hydrogen Carrier Gas Application Brief Doris Smith and Kenneth Lynam Environmental Analysis time is often a limiting factor in sample turnaround for a laboratory. In…
Key words
bhc, bhcendosulfan, endosulfanendrin, endrinclp, clpchlordane, chlordaneheptachlor, heptachlortelodrin, telodrinpesticides, pesticideskepone, keponetetrachloro, tetrachlorosplitter, splittersurrogate, surrogatedecachlorobiphenyl, decachlorobiphenylmirex, mirexmethoxychlor
GC-μECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil
2012|Agilent Technologies|Applications
GC-µECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil Application Note Food Safety and Environmental Markets Authors Abstract Jennifer McCulley and Ken Lynam An olive oil sample obtained from a local grocery store is analyzed for 20…
Key words
bhc, bhcendosulfan, endosulfanendrin, endrinolive, oliveoil, oilchlordane, chlordaneheptachlor, heptachlorsurrogate, surrogatetetrachloro, tetrachloroµecd, µecdsulfate, sulfatemethoxychlor, methoxychlorxylene, xylenexlb, xlbquechers