Sampling with MiniCans and Bottle-Vacs
Applications | | ENTECHInstrumentation
Volatile organic compounds (VOCs) and light semivolatiles in air are of critical concern in environmental monitoring, industrial hygiene, and regulatory compliance. Traditional adsorbent methods face challenges such as breakthrough, inconsistent recoveries, and volume measurement errors. Canister sampling with inert internal surfaces overcomes these issues, enabling accurate measurement from parts-per-million to sub-parts-per-billion levels and offering long-term stability of collected samples.
This application note presents an in-depth evaluation of two compact evacuated sampling canisters—Silonite™-coated MiniCans and deactivated-glass Bottle-Vacs. It outlines criteria for container selection, detailed procedures for grab, short-term, and long-term integrated sampling, and guidance on achieving required detection limits and reliable analyte recovery across various field scenarios.
Sampling strategies are defined by three key parameters: target detection limits, need for duplicate samples, and desired integration time (grab, short-term, or long-term). MiniCans feature fused-silica coatings to emulate gas chromatography (GC) column surfaces, while Bottle-Vacs use deactivated amber glass. Flow control for time-integrated sampling employs critical orifice inlets for 1–30 min periods and the CS1200 series vacuum flow controllers for extended sampling up to 24 h. Helium Diffusion Sampling (HDS) extends personal monitoring capabilities. Each procedure includes vacuum verification, valve operation, use of particulate filters (Silonite-coated stainless steel), and pressure monitoring to ensure consistent sample volumes.
Both MiniCans and Bottle-Vacs demonstrate exceptional recoveries for GC-compatible VOCs and semivolatiles, with storage stability up to 30 days and detection limits reaching 1 ppb or lower on modern GC-MS systems. Silonite™ coatings enhance recovery of polar analytes (e.g., formaldehyde). Critical orifice sampling enables precise short-term integration, while the CS1200 series delivers stable long-term flows even at low rates. Helium Diffusion Sampling successfully reduces collection rate by 10–20× for personal exposures, albeit at slightly higher detection limits.
Performance-based sampling methods will continue to evolve with novel surface coatings and miniaturized flow controllers. Advances in sensor integration and automated networks may enable real-time VOC mapping. Ongoing optimization of Helium Diffusion Sampling could expand personal monitoring into sub-ppb dynamic environments. Enhanced compatibility with next-generation GC-MS instruments will push detection limits further and broaden compound coverage.
Compact Silonite™-coated MiniCans and deactivated-glass Bottle-Vacs offer versatile, cost-effective solutions for reliable VOC sampling across diverse field applications. By matching canister size, surface treatment, and flow control to monitoring objectives, practitioners can achieve robust detection limits, stable storage, and consistent recoveries in regulatory and research settings.
Cardin D. Sampling with MiniCans and Bottle-Vacs. Application Note A-3730-01. Entech Instruments, Inc., Simi Valley, CA.
Sample Preparation
IndustriesEnvironmental
ManufacturerENTECH
Summary
Importance of the topic
Volatile organic compounds (VOCs) and light semivolatiles in air are of critical concern in environmental monitoring, industrial hygiene, and regulatory compliance. Traditional adsorbent methods face challenges such as breakthrough, inconsistent recoveries, and volume measurement errors. Canister sampling with inert internal surfaces overcomes these issues, enabling accurate measurement from parts-per-million to sub-parts-per-billion levels and offering long-term stability of collected samples.
Objectives and overview
This application note presents an in-depth evaluation of two compact evacuated sampling canisters—Silonite™-coated MiniCans and deactivated-glass Bottle-Vacs. It outlines criteria for container selection, detailed procedures for grab, short-term, and long-term integrated sampling, and guidance on achieving required detection limits and reliable analyte recovery across various field scenarios.
Methodology
Sampling strategies are defined by three key parameters: target detection limits, need for duplicate samples, and desired integration time (grab, short-term, or long-term). MiniCans feature fused-silica coatings to emulate gas chromatography (GC) column surfaces, while Bottle-Vacs use deactivated amber glass. Flow control for time-integrated sampling employs critical orifice inlets for 1–30 min periods and the CS1200 series vacuum flow controllers for extended sampling up to 24 h. Helium Diffusion Sampling (HDS) extends personal monitoring capabilities. Each procedure includes vacuum verification, valve operation, use of particulate filters (Silonite-coated stainless steel), and pressure monitoring to ensure consistent sample volumes.
Used Instrumentation
- MiniCan™ canisters (0.04–1.4 L) with Silonite™ coating
- Bottle-Vac™ canisters (40 mL–32 oz) with Micro-QT inlet valve
- Micro-QT low-volume stainless steel valves
- Critical orifice samplers (15–600 cc/min flows)
- CS1200E/P vacuum flow controllers (0.3–600 cc/min range)
- Silonite™-coated stainless steel particulate filters
- Vacuum gauges for pre-sampling verification
Main results and discussion
Both MiniCans and Bottle-Vacs demonstrate exceptional recoveries for GC-compatible VOCs and semivolatiles, with storage stability up to 30 days and detection limits reaching 1 ppb or lower on modern GC-MS systems. Silonite™ coatings enhance recovery of polar analytes (e.g., formaldehyde). Critical orifice sampling enables precise short-term integration, while the CS1200 series delivers stable long-term flows even at low rates. Helium Diffusion Sampling successfully reduces collection rate by 10–20× for personal exposures, albeit at slightly higher detection limits.
Benefits and practical applications
- Reduced container size, weight, and cost compared to 6 L SUMMA canisters
- High inertness and broad analyte compatibility without breakthrough or adsorption bias
- Field duplication becomes cost-effective, improving data reliability
- Flexible sampling regimes from rapid grab to multi-day integrated monitoring
- Personal exposure assessment enabled by HDS and belt-worn CS1200P
Future trends and potential applications
Performance-based sampling methods will continue to evolve with novel surface coatings and miniaturized flow controllers. Advances in sensor integration and automated networks may enable real-time VOC mapping. Ongoing optimization of Helium Diffusion Sampling could expand personal monitoring into sub-ppb dynamic environments. Enhanced compatibility with next-generation GC-MS instruments will push detection limits further and broaden compound coverage.
Conclusion
Compact Silonite™-coated MiniCans and deactivated-glass Bottle-Vacs offer versatile, cost-effective solutions for reliable VOC sampling across diverse field applications. By matching canister size, surface treatment, and flow control to monitoring objectives, practitioners can achieve robust detection limits, stable storage, and consistent recoveries in regulatory and research settings.
Reference
Cardin D. Sampling with MiniCans and Bottle-Vacs. Application Note A-3730-01. Entech Instruments, Inc., Simi Valley, CA.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Improving Canister Sampling Accuracy and Reliability Using Helium Diffusion Sampling into Silonite Coated Stainless Steel Canisters
|Agilent Technologies|Applications
Improving Canister Sampling Accuracy and Reliability Using Helium Diffusion Sampling into Silonite Coated Stainless Steel Canisters INSTRUMENTS INC. Application Note: A-3731-01 Authors Daniel B. Cardin Thomas X. Robinson Daniel J. Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract A…
Key words
sampling, samplingcanister, canisterhds, hdsdiffusion, diffusioncanisters, canistersair, airhelium, heliumover, overgauge, gaugesampler, samplervacuum, vacuumsilonite, silonitevac, vacatmospheric, atmosphericorifice
Silonite™ MicroValves™ - High Performance, Chromatographic Grade Quick Connect Valves
2019|ENTECH|Brochures and specifications
Silonite™ MicroValves™ SILONITE™ MicroValves™ High Performance, Chromatographic Grade Quick Connect Valves. Tool Free, Leak Free - Micro-QT™ The Micro-QT is a next generation gas valve offering uncompromising leak-tight performance in an ergonomic design. The Micro-QT is also versatile, providing numerous…
Key words
silonite, silonitemicro, micromale, malefemale, femalevalve, valvemqt, mqtmicrovalve, microvalvefitting, fittingmicrovalves, microvalvessampling, samplinggrab, grabvalves, valvesluer, luerfqt, fqtluers
A New Approach to Whole Air Sampling using Deactivated Glass Bottles
|Agilent Technologies|Applications
A New Approach to Whole Air Sampling using Deactivated Glass Bottles INSTRUMENTS INC. Application Note: A-3727-01 Authors Chris Casteel Daniel B. Cardin Entech Instruments, Inc. Simi Valley, CA 93065 32 oz and 16 oz Bottle-Vac Samplers with ultra-leak-tight Micro-QT Valves.…
Key words
vac, vacbottle, bottlesampling, samplingsamplers, samplerscanister, canistercanisters, canisterscontainer, containertedlar, tedlarevacuation, evacuationbags, bagsrecovery, recoverywhole, wholeair, airsilonite, silonitedeactivated
CS1200E Passive Canister Sampler - Solutions for Time Integrated Canister Sampling
2019|ENTECH|Brochures and specifications
CS1200E Passive Canister Sampler CS1200E PASSIVE Canister Sampler Solutions for Time Integrated Canister Sampling. CS1200E Passive Canister Sampler The best solution for low level EPA TO-15 monitoring. Features The CS1200E is a high-purity flow regulation system designed to reliably fill…
Key words
silonite, silonitecoated, coatedcanister, canisterrestrictor, restrictoruncoated, uncoatedsampler, samplercanisters, canistersintegrated, integratedsampling, samplinginlet, inletabsorptive, absorptivepackaging, packagingfilter, filterflow, flowtape