Importance of the Topic


Active mold growth emits microbial volatile organic compounds (MVOCs) that are reliable indicators of ongoing or recent mold activity in indoor environments.
Detecting these compounds rapidly and accurately is critical for protecting human health and ensuring air quality.

Study Objectives and Overview


This study evaluates a novel canister-based sampling method for the analysis of approximately 20 MVOCs associated with mold growth.
The goals include demonstrating rapid field sampling, reproducible laboratory analysis, calibration performance, and field applicability in a residential setting.

Methodology and Instrumentation


The approach couples heated Silonite-coated stainless steel canisters with automated thermal desorption and GC-MS analysis.
  • Sample Collection: 0.4 L fused-silica lined canisters filled in seconds without pump calibration.
  • Autosampler: Entech 7500 robotic heated inlet system (oven at 80 °C, 10 min equilibration) for direct canister sampling.
  • Preconcentration: Entech 7100A three-stage trap with glass bead/Tenax at 40 °C and –30 °C, thermal desorption at 180 °C, water/CO₂ management.
  • Chromatography and Detection: HP 5890II GC with DB-5 column (30 m × 0.32 mm, 1 µm film), oven ramp 37 °C to 240 °C, interfaced to 5971A MS scanning 35–155 amu.

Main Results and Discussion


A six-point calibration from 0.4 to 4 ppbv yielded relative standard deviations in line with common air monitoring methods (e.g., EPA TO-15).
Method detection limits were calculated from seven replicate analyses at 0.1 ppbv using a Student’s t-value of 3.14.
In a field grab sample from a household garbage disposal, MVOCs such as 2-butanone (0.3 ppbv) and 1-octanol (0.8 ppbv) were detected, totaling approximately 8 ng/L, indicating low health risk under ambient conditions.

Benefits and Practical Applications


The canister sampling technique offers rapid (< 10 s) collection without complex pump calibration and requires minimal user training.
Automated heated desorption preserves high-molecular-weight MVOCs and ensures reproducible results, making it suitable for residential mold screening, industrial hygiene, and indoor air quality assessments.

Future Trends and Applications


Emerging opportunities include integration of real-time MVOC sensors, portable preconcentration modules, and machine-learning algorithms for pattern recognition of mold indicators.
Expanded use in building diagnostics, environmental monitoring networks, and smart home systems is anticipated.

Conclusion


This study demonstrates an effective, streamlined approach to MVOC detection using heated canister sampling and automated GC-MS analysis.
The method delivers rapid, sensitive, and reproducible results consistent with established air sampling protocols, potentially lowering barriers for widespread mold assessment.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
A New Approach to Whole Air Sampling using Deactivated Glass Bottles
A New Approach to Whole Air Sampling using Deactivated Glass Bottles INSTRUMENTS INC. Application Note: A-3727-01 Authors Chris Casteel Daniel B. Cardin Entech Instruments, Inc. Simi Valley, CA 93065 32 oz and 16 oz Bottle-Vac Samplers with ultra-leak-tight Micro-QT Valves.…
Key words
vac, vacbottle, bottlesampling, samplingsamplers, samplerscanister, canistercanisters, canisterscontainer, containertedlar, tedlarevacuation, evacuationbags, bagsrecovery, recoverywhole, wholeair, airsilonite, siloniteglass
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Thermo Scientific ISQ QD GCMS
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Thermo Scientific ISQ QD GCMS INSTRUMENTS INC. Application Note: A-3736-02 Authors Doug Markle Chris Casteel Tom Robinson Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065…
Key words
canisters, canisterstrapping, trappingsilonite, siloniteair, aircanister, canistertrap, trapisq, isqpreconcentration, preconcentrationvolume, volumeconcentration, concentrationsample, sampleaccu, accuvery, veryentech, entechgcms
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Shimadzu QP2010 Ultra GCMS
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Shimadzu QP2010 Ultra GCMS INSTRUMENTS INC. Application Note: A-3736-01 Authors Doug Markle Chris Casteel Tom Robinson Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract…
Key words
silonite, siloniteair, airtrapping, trappingaccidently, accidentlycanister, canistersample, sampletrap, trapvolume, volumeinert, inertaccu, accuentech, entechlittle, littlecompounds, compoundscanisters, canisterskeeps
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Agilent 7890B/5977 GCMS
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Agilent 7890B/5977 GCMS Application Note: A-3737-01 Authors Tom Robinson Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract Canister sampling and analysis for measurement of…
Key words
trap, trapcanister, canistercanisters, canistersair, airtrapping, trappinglow, lowcompounds, compoundspreconcentration, preconcentrationvolume, volumewhich, whichnext, nextsilonite, siloniteinertness, inertnessfocusing, focusingwater
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike