Magnetic Sector GC-HRMS - Dioxin and POPs analysis

Others | 2018 | Thermo Fisher ScientificInstrumentation
GC/MSD, GC/HRMS
Industries
Environmental, Food & Agriculture
Manufacturer
Thermo Fisher Scientific

Summary

Significance of the Topic

Magnetic Sector GC-HRMS represents the benchmark for high-resolution and high-selectivity analysis of dioxins and persistent organic pollutants (POPs). Its proven regulatory compliance and robust performance make it essential for reliable quantitative testing in environmental monitoring, food safety, and research applications.

Objectives and Study Overview

This application note highlights the key advantages of Thermo Scientific DFS Magnetic Sector GC-HRMS technology for routine dioxin and POPs analysis. It reviews performance criteria, regulatory approvals, unique system features, and practical benefits for laboratories worldwide.

Methodology and Used Instrumentation

Thermo Scientific DFS Magnetic Sector GC-HRMS combines gas chromatography with a magnetic sector mass spectrometer, delivering exceptional resolution across the entire mass range. Core instrumental components and features include:
  • Large-volume ion source for high sensitivity and consistent performance with complex matrices
  • High-capacity turbo pump dedicated to the ion source to enhance robustness
  • Lock mass tracing for continuous stability monitoring and real-time S/N-based LOD/LOQ calculation
  • Automated mass calibration at the start of each run
  • Unique ion separation in space and mass-independent resolution for uniform selectivity
  • Dual GC configuration with optional multi-column installation (up to four columns)
  • Optional DualData XL for nearly doubled sample throughput
  • Exchangeable ion volume and separation valve for simplified maintenance without breaking vacuum

Main Results and Discussion

Compliance testing confirms that the DFS Magnetic Sector GC-HRMS meets or exceeds worldwide official methods including EPA 1613, EPA 1614, EN 16215, EN 1948, JIS K0311, and others. Key performance highlights:
  • Best-in-class installation specifications based on 2378-TCDD with a four-sigma noise definition
  • High linearity and matrix-independent calibration routines ensuring accurate quantitation
  • Consistent high-mass sensitivity (e.g., BDE-209) and spectral reproducibility
  • Documented resolution and selectivity logged with each analysis for full traceability

Benefits and Practical Applications

Laboratories benefit from:
  • Regulatory confidence through adherence to global dioxin and POPs standards
  • Enhanced throughput via dual GC paths and automated workflows
  • Reduced downtime with rapid ion source maintenance and vacuum-secured component exchange
  • Adaptability to various reference gases and column configurations for method flexibility

Future Trends and Opportunities

Advancements may include tighter software integration for automated method development, expanded high-throughput capabilities, cloud-based data management for global collaboration, and coupling with novel sample preparation techniques to address emerging environmental contaminants.

Conclusion

The DFS Magnetic Sector GC-HRMS stands as a gold-standard solution for dioxin and POPs analysis, delivering unmatched resolution, sensitivity, and regulatory compliance. Its robust design and versatile configuration support both routine quantitative workflows and advanced research needs.

References

No explicit bibliographic references were provided in the original text.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Thermo Scientific DFS Magnetic Sector GC-HRMS - Setting the Gold Standard for Dioxin and POPs Analysis
Worldwide Compliance Setting the Gold Standard for Dioxin and POPs Analysis Thermo Scientific DFS Magnetic Sector GC-HRMS Powering Dioxin and POPs analysis around the world The Thermo Scientific™ DFS™ Magnetic Sector GC-HRMS is the gold standard for performing Dioxin and…
Key words
sector, sectordfs, dfsapproved, approvedmagnetic, magnetichrms, hrmsdioxin, dioxinion, ionflexibility, flexibilitysource, sourceenvironmental, environmentalpops, popssafety, safetydualdata, dualdataconfiguration, configurationofficial
Magnetic Sector GC-HRMS - Dioxin and POPs applications
Magnetic Sector GC-HRMS - Dioxin and POPs applications
2018|Thermo Fisher Scientific|Others
Magnetic Sector GC-HRMS SmartNotes Which Dioxin and POPs applications can the DFS Magnetic Sector GC-HRMS be used for? Dioxins and other persistent organic pollutants (POPS) are everywhere, from the environment to our food. Laboratories need to analyze samples to find…
Key words
approved, approvedsector, sectorhrms, hrmsdfs, dfsmagnetic, magneticenvironmental, environmentalsafety, safetyfood, foodeurl, eurlpops, popssmartnotes, smartnotescontaminants, contaminantsdown, downrecommended, recommendednorm
Powering Dioxin and POPs analysis around the world - PRODUCT SPECIFICATIONS
Powering Dioxin and POPs analysis around the world - PRODUCT SPECIFICATIONS
2021|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS 30096 Powering Dioxin and POPs analysis around the world DFS Magnetic Sector GC-HRMS Keywords: Magnetic Sector, Dioxin analysis, PCDD/F, PCBs, PBDEs and other POPs, global compliance, food and environmental samples Benefits • Global compliance with official methods •…
Key words
dfs, dfssector, sectorhrms, hrmsmagnetic, magneticprobe, probethermo, thermoscientific, scientifictargetquan, targetquandioxin, dioxinvacuum, vacuumoptional, optionalsoftware, softwareionization, ionizationcompliant, compliantanalyzer
Thermo Scientific Protecting the Environment - Persistent organic pollutant analysis - Comprehensive workflows for regulatory compliance
Thermo Scientific Protecting the Environment Persistent organic pollutant analysis Comprehensive workflows for regulatory compliance Persistent Organic Pollutant Analysis Table of Contents POPs background Comprehensive solutions overview Sample preparation solutions Columns and consumables ASE and SPE automation / accessories Sample analysis…
Key words
pops, popsthermo, thermoscientific, scientificdfs, dfsorbitrap, orbitrapsector, sectoraccelerated, acceleratedexactive, exactivehrms, hrmsmagnetic, magneticquantitation, quantitationscreening, screeningconsumables, consumablesmass, massultimate
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike