Catalytic Ammonia Cracking: Reaction Monitoring Using the Agilent 990 Micro GC System
Applications | 2024 | Agilent TechnologiesInstrumentation
Ammonia serves as a clean hydrogen carrier and potential zero-carbon fuel, playing a key role in decarbonizing sectors like shipping, heavy-duty transport and power generation. Accurate monitoring of ammonia cracking is essential for catalyst performance evaluation, process optimization and safety compliance.
This work evaluates the Agilent 990 Micro GC system equipped with a CP-Molsieve backflush channel and a CP-Volamine straight channel. The goal is simultaneous quantitation of NH3, H2, N2 and H2O across trace to bulk concentration ranges with a sub-one-minute cycle time.
The Agilent 990 Micro GC system with CP-Volamine and CP-Molsieve channels delivers rapid, precise and robust measurement of NH3, H2, N2 and H2O over a wide concentration range. Its high throughput, minimal carryover and flexible stream switching make it ideal for monitoring ammonia cracking reactions in sustainable hydrogen production.
GC
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
Significance of the Topic
Ammonia serves as a clean hydrogen carrier and potential zero-carbon fuel, playing a key role in decarbonizing sectors like shipping, heavy-duty transport and power generation. Accurate monitoring of ammonia cracking is essential for catalyst performance evaluation, process optimization and safety compliance.
Aims and Study Overview
This work evaluates the Agilent 990 Micro GC system equipped with a CP-Molsieve backflush channel and a CP-Volamine straight channel. The goal is simultaneous quantitation of NH3, H2, N2 and H2O across trace to bulk concentration ranges with a sub-one-minute cycle time.
Methodology and Instrumentation
- System configuration:
- CP-Molsieve 5 Å, 10 m with 1 m backflush for H2/N2 separation
- CP-Volamine, 15 m straight channel for NH3/H2O analysis
- Carrier gases: Argon (29 psi) on Molsieve channel; Helium (22 psi) on Volamine channel
- Injector at 110 °C; column temperatures: 80 °C (Molsieve), 50 °C (Volamine)
- Injection time: 40 ms; backflush time (Molsieve): 4.5 s; total cycle time ≈ 1 min
- Stream selection valves for alternating reactor inlet, outlet and calibration gases
- Calibration approach:
- Mass flow controllers for NH3, H2 and N2 mixtures
- Syringe pump injection of water into heated manifold for liquid calibration
Main Results and Discussion
- Chromatography: Clear separation of NH3 and H2O on the Volamine channel; composite H2/N2 peak resolved on Molsieve channel.
- Linearity: R² ≥ 0.999 for NH3, H2 and N2; R² = 0.9982 for H2O.
- Limit of Detection (NH3): ~ 0.65 ppm (based on 8.996 ppm standard, RSD 2.71%).
- Precision and robustness: 100% NH3 injections over 21 030 runs yielded area RSD 0.13% and retention time RSD 0.07%.
- Carryover: Switching from 100% to 300 ppm NH3 stabilizes within 20–30 injections; no significant memory effects when returning to high concentration.
Benefits and Practical Applications
- Sub-minute quantitation of ammonia cracking feed and product streams supports real-time process control.
- High reproducibility and low carryover ensure reliable long-term monitoring in catalyst testing.
- Stream selection enables multiplexed reactor analysis without additional hardware.
- Applicable to QA/QC in hydrogen production and catalyst development workflows.
Future Trends and Opportunities
- Integration with automated pilot plants and real-time optimization platforms.
- Extension to additional trace impurities (e.g., CO2) as ammonia-based processes evolve.
- Miniaturized micro GC modules for distributed monitoring in fuel cells and mobile units.
- Coupling micro GC data with AI-driven analytics for predictive maintenance and advanced control.
Conclusion
The Agilent 990 Micro GC system with CP-Volamine and CP-Molsieve channels delivers rapid, precise and robust measurement of NH3, H2, N2 and H2O over a wide concentration range. Its high throughput, minimal carryover and flexible stream switching make it ideal for monitoring ammonia cracking reactions in sustainable hydrogen production.
Reference
- Marrin P., Moss J. Ammonia as an Essential Energy Carrier for the Energy Transition. Commissioned by Amogy, 3Q 2023.
- Amogy. Ammonia as an Essential Energy Carrier: Essential for the Energy Transition. September 5, 2023.
- Geng S. Ammonia Analysis Using the Agilent 990 Micro GC; Agilent Technologies application note 5994-4346EN, 2021.
- Amogy. About Amogy. Accessed Oct 24, 2024.
- Zhang J. Analysis of Fischer-Tropsch Syngas and Tail Gas with the Agilent 990 Micro GC; Agilent application note 5994-6904EN, 2023.
- Zhang J. Coal Mine Gas Analysis with the Agilent 990 Micro GC; Agilent application note 5994-5953EN, 2023.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Coal Mine Gas Analysis with the Agilent 990 Micro GC
2023|Agilent Technologies|Applications
Application Brief Energy & Chemicals Coal Mine Gas Analysis with the Agilent 990 Micro GC Author Jie Zhang Agilent Technologies (Shanghai) Co. Ltd. Abstract In this application brief, a fast coal mine gas analysis was performed on an Agilent 990…
Key words
ppu, ppumolsieve, molsievechannel, channelresponse, responsebackflush, backflushppq, ppqgas, gasmine, minecoal, coalagilent, agilentcarrier, carrierhelium, heliumtime, timemol, molargon
990 Micro GC - Data Sheet Compendium
2025|Agilent Technologies|Brochures and specifications
990 Micro GC Data Sheet Compendium Table of Contents Data sheets for 990 Micro GC 990 Micro GC 3 990 Mobile Micro GC 6 990-PRO Micro GC 9 Data sheets for 990 analytical channels CP-Molsieve 5Å 12 Hayesep A 14…
Key words
channel, channelyes, yesmicromachined, micromachinedtcd, tcdselectable, selectabledetector, detectorprecolumn, precolumninjector, injectorlength, lengthfilaments, filamentsbackflush, backflushsea, seaporaplot, poraplothayesep, hayesepcontrol
Ammonia Analysis Using the Agilent 990 Micro GC
2021|Agilent Technologies|Applications
Application Note Energy and Chemicals Ammonia Analysis Using the Agilent 990 Micro GC Author Sheng Geng Agilent Technologies, Inc. (Shanghai) Co. Ltd. Shanghai 200131 P. R. China Abstract The Agilent 990 Micro GC with the Agilent J&W CP-Volamine column is…
Key words
ammonia, ammoniarsd, rsdmonths, monthstime, timeminutes, minutesarea, arearetention, retentionbalance, balancecontaining, containinggeng, gengconcentration, concentrationmpd, mpdsheng, shengpath, pathvolamine
Micro GC Analysis of Permanent Gas Impurities in PEM Fuel Cell-Grade Hydrogen
2025|Agilent Technologies|Applications
Application Note Energy Micro GC Analysis of Permanent Gas Impurities in PEM Fuel Cell-Grade Hydrogen According to SAE J2719, ISO 14687, EN 17124, and ISO 19880-8 Authors Abstract Shannon Coleman, Rob de Jong, Brandon Jones, Kelly Beard, and Jie Zhang…
Key words
µgc, µgcppm, ppmhydrogen, hydrogenargon, argonpermanent, permanentpem, pemmeth, methfuel, fuelneon, neonfid, fidhelium, heliumgatzke, gatzkemcpherson, mcphersonsenia, seniarepeatabilty