Determination of Polybrominated Diphenylethers (PBDE) in Sediment and Sewage Sludge

Applications | 2004 | Agilent TechnologiesInstrumentation
GC/MSD, GC/SQ
Industries
Environmental
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Polybrominated diphenyl ethers (PBDEs) are widely used flame retardants in electronics, textiles and plastics. Their environmental persistence and tendency to bioaccumulate have raised concerns similar to those for PCBs. As regulatory bodies tighten limits on PBDE discharge, reliable methods to detect low concentrations in sediments and sewage sludge are essential for risk assessment and compliance.

Goals and Study Overview


This study aimed to develop and validate a robust GC/MS protocol for the separation and quantification of five priority PBDE congeners, including the challenging decabromodiphenyl ether (BDE-209), in sediment and sewage sludge. The method supports European water directive 2000/60/EC requirements and forthcoming ISO/CD 22032 norms.

Methodology and Instrumentation


Samples (10 g sediment or 1 g sludge) were extracted with hexane, cleaned over silica gel and concentrated to 1 mL. Separation employed an Agilent 6890 GC fitted with a 30 m×0.32 mm DB-1 capillary column (0.1 μm film) and pulsed splitless injection at 250 °C. Detection used an Agilent 5973 inert mass selective detector in SIM mode, monitoring characteristic ions for each congener. TetraBDE (BDE-77) served as internal standard.

Main Results and Discussion


Optimized oven programming and pulsed injection minimized thermal degradation of high-brominated congeners. Chromatograms showed sharp, well-resolved peaks for penta-, octa- and decaBDE. Calibration curves over 0.01–4 ng/μL yielded R²≥0.996. Limits of detection met regulatory targets (1 μg/kg for pentaBDE; 50 μg/kg for octa/decaBDE). Analysis of real sludge confirmed accurate quantification of BDE-99 and BDE-209.

Advantages and Practical Applications


The use of an inert thin-film DB-1 column and pulsed splitless injection reduces analyte adsorption and thermal breakdown, enabling reproducible, low-level detection. This method is applicable for routine environmental monitoring, quality assurance in wastewater treatment, and compliance with emerging regulations.

Future Trends and Potential Applications


Further work may extend the method to other brominated and chlorinated flame retardants, integrate high-resolution mass spectrometry for confirmatory analysis, automate sample preparation for higher throughput, and fully align with ISO standardization efforts for comprehensive environmental surveillance.

Conclusion


This GC/MS approach offers a sensitive, robust solution for the determination of key PBDE congeners in sediment and sewage sludge, supporting regulatory compliance and environmental health assessments.

Reference


  • Eriksson P., Jakobsson E., Fredriksson A. Developmental neurotoxicity of brominated flame retardants. Organohalogen Compounds 1998, 35, 375–377.
  • Hallgren S., Darnerud P.O. Effects of polybrominated diphenyl ethers, PCBs and chlorinated paraffins on thyroid hormones in rats. Organohalogen Compounds 1998, 35, 391–394.
  • Darnerud P.O., Thuvander A. Immunological effects of PBDE and PCB exposure in rodents. Organohalogen Compounds 1998, 35, 415–418.
  • European Commission. Directive 2000/60/EC establishing a framework for Community action in the field of water policy.
  • Kuhn E., Ellis J., Wilbur S. GC Analysis of Polybrominated Flame Retardants. Agilent Technologies publication, 5989-0094EN, 1999.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Solutions that meet your demands - Environmental Compendium - Emerging Contaminants
Solutions that meet your demands for: speed accuracy productivity Excellent choices for environmental applications Emerging Contaminants PPCPs Applications > Return to Table of Contents > Search entire document Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive…
Key words
pbde, pbdebde, bdepfoa, pfoapbdes, pbdesabundance, abundancepfos, pfospolybrominated, polybrominatedusa, usaion, ionmass, massdiphenyl, diphenylagilent, agilentfragmentor, fragmentorcompounds, compoundscollision
Determination of Polybrominated Diphenyl Ethers in Polymeric Materials Using the 6890 GC/5973N inert MSD with Electron Impact Ionization
Determination of Polybrominated Diphenyl Ethers in Polymeric Materials Using the 6890 GC/5973N inert MSD with Electron Impact Ionization Application Environmental, Component Testing Authors Introduction Chuanhong Tu Agilent Technologies, PuDong Shanghai CHINA Polybrominated diphenyl ethers (PBDEs) are a major issue in…
Key words
pbde, pbdeabundance, abundancepbdes, pbdeshexabdes, hexabdesoctabdes, octabdeshexa, hexapolymer, polymerdeca, decasim, simheptabdes, heptabdesnonabdes, nonabdespolybrominated, polybrominatedpolymeric, polymericcongeners, congenersdiphenyl
Overcoming Analytical Challenges in PBDEs Quantification in Environmental Samples using GC-Orbitrap MS
Overcoming Analytical Challenges in PBDEs Quantification in Environmental Samples using GC-Orbitrap MS Jane Cooper1, Jordi Parera2, Esteban Abad2, Richard Law1, and Cristian Cojocariu1 Thermo Fisher Scientific, Runcorn, UK 2 Laboratory of Dioxins, Dept. of Environmental Chemistry, Institute of Environmental Assessment…
Key words
pbdes, pbdesexactive, exactivebde, bdeorbitrap, orbitrappolybrominated, polybrominatedethers, ethersdiphenyl, diphenylether, etherpbde, pbdesludge, sludgescientific, scientifictetrabdes, tetrabdesthermo, thermobdes, bdesenvironmental
Overcoming analytical challenges for polybrominated diphenyl ethers (PBDEs) analysis in environmental samples using gas chromatography – Orbitrap mass spectrometry
APPLICATION NOTE 10644 Overcoming analytical challenges for polybrominated diphenyl ethers (PBDEs) analysis in environmental samples using gas chromatography – Orbitrap mass spectrometry Authors Goal Jane Cooper,1 Jordi Parera,2 Esteban Abad,2 Richard Law,¹ and Cristian Cojocariu1 1 Thermo Fisher Scientific, Runcorn,…
Key words
bde, bdepbdes, pbdespbde, pbdecounts, countsexactive, exactivebdes, bdesisotopic, isotopicquantification, quantificationwere, weredibdes, dibdesmonobde, monobdetribdes, tribdesnumber, numberheptabdes, heptabdesenvironmental
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike