Automated difficult matrix introduction (DMI) for identification of allergens and fragrances in washing powder with GC-MS-Olfactometry and a liner exchanger (LINEX)
Applications | | GL SciencesInstrumentation
The identification and quantification of allergens and fragrances in complex matrices such as washing powders is critical for product safety, regulatory compliance and quality control. The Difficult Matrix Introduction (DMI) technique automates sample preparation and directly introduces solid samples into the GC injector, minimizing sample handling and loss of volatile compounds. Coupled with GC-MS-Olfactometry and an automated liner exchanger (LINEX), DMI enhances throughput and sensitivity for routine screening of consumer products.
The study aimed to demonstrate the applicability of automated DMI-GC-MS-Olfactometry for comprehensive profiling of detergents. Specific objectives included pattern recognition of ingredients, identification of unknown peaks, quantification of known compounds, and real-time olfactory assessment of fragrances in perfumed products—all within a single analytical run.
Sample Preparation:
As consumer products become more complex, further integration of DMI with two-dimensional GC, cryo-trapping and high-resolution mass spectrometry may expand analyte coverage and sensitivity. Coupling with data-driven pattern recognition and machine learning could enable automated identification of emerging allergens and fragrance compounds. Miniaturized, portable DMI-GC-MS-O devices may find applications in on-site quality control.
The DMI-GC-MS-Olfactometry approach with an automated liner exchanger offers a robust, sensitive and efficient solution for simultaneous chemical and sensory analysis of washing powders. Its minimal sample preparation, high reproducibility and real-time olfactory detection make it well suited for routine screening and quality control in consumer product laboratories.
GC/MSD, GC/SQ
IndustriesOther
ManufacturerShimadzu, GL Sciences
Summary
Significance of the topic
The identification and quantification of allergens and fragrances in complex matrices such as washing powders is critical for product safety, regulatory compliance and quality control. The Difficult Matrix Introduction (DMI) technique automates sample preparation and directly introduces solid samples into the GC injector, minimizing sample handling and loss of volatile compounds. Coupled with GC-MS-Olfactometry and an automated liner exchanger (LINEX), DMI enhances throughput and sensitivity for routine screening of consumer products.
Objectives and Study Overview
The study aimed to demonstrate the applicability of automated DMI-GC-MS-Olfactometry for comprehensive profiling of detergents. Specific objectives included pattern recognition of ingredients, identification of unknown peaks, quantification of known compounds, and real-time olfactory assessment of fragrances in perfumed products—all within a single analytical run.
Methodology and Instrumentation
Sample Preparation:
- Weigh 1–8 mg of washing powder into a micro-vial and insert into a DMI liner.
- GC column: Inertcap wax (0.32 mm×60 m, 0.5 μm film).
- GC oven program: 40°C (6.3 min hold) → 15°C/min to 130°C → 3°C/min to 250°C (25 min hold).
- Carrier gas: helium at 1.0 mL/min (without sniffing) and 5.0 mL/min (split between MS and sniffing port).
- PTV injector (OPTIC 3): 35°C to 250°C at 5°C/sec.
- Split flow: start 1.5 min at 150 mL/min (liner flush), 1:40 split ratio during heating and analysis.
- GC-MS: Shimadzu GC-MS-QP2010.
- Olfactometry: PHASER sniffing port.
- Autosampler: FOCUS with LINEX liner exchanger.
- Analyte range: hydrocarbons from C11H24 to C44H50 (lower masses accessible via optional cryo-trap).
Main Results and Discussion
- Detection limits for thermally stable, low-polarity compounds were between 0.1 and 0.02 ng per micro-vial.
- Reproducibility of retention times was <4% RSD and peak areas <13% RSD across ten replicate injections.
- Analysis covered a broad range of glycols, ethers and high-molecular-weight fragrance components without any prior extraction steps.
- Real-time sniffing allowed simultaneous chemical and sensory profiling, facilitating direct correlation between chromatographic peaks and odor characteristics.
- Minimal sample size reduced consumable costs and potential analyte losses during preparation; however, sample heterogeneity was managed by maximizing powder weight in the micro-vial.
Benefits and Practical Applications
- Automated workflow reduces operator intervention and analysis time.
- Elimination of conventional sample preparation avoids solvent use and potential analyte volatility losses.
- High throughput screening of detergents for allergens and fragrances aligns with QA/QC and regulatory screening requirements.
- Incorporation of olfactometry provides added value for fragrance profiling in perfumed products.
Future Trends and Potential Applications
As consumer products become more complex, further integration of DMI with two-dimensional GC, cryo-trapping and high-resolution mass spectrometry may expand analyte coverage and sensitivity. Coupling with data-driven pattern recognition and machine learning could enable automated identification of emerging allergens and fragrance compounds. Miniaturized, portable DMI-GC-MS-O devices may find applications in on-site quality control.
Conclusion
The DMI-GC-MS-Olfactometry approach with an automated liner exchanger offers a robust, sensitive and efficient solution for simultaneous chemical and sensory analysis of washing powders. Its minimal sample preparation, high reproducibility and real-time olfactory detection make it well suited for routine screening and quality control in consumer product laboratories.
Used Instrumentation
- Injector: OPTIC 3 PTV injector (ATAS GL International).
- GC-MS: Shimadzu GC-MS-QP2010.
- Olfactometry: PHASER sniffing port (ATAS GL International).
- Autosampler: FOCUS with LINEX liner exchanger (ATAS GL International).
- GC column: Inertcap wax, 0.32 mm×60 m, 0.5 μm film.
References
- H. Jing and A. Amirav, "Difficult matrix introduction for direct analysis of complex solids," Analytical Chemistry, vol. 69, pp. 1426–1434, 1997.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Automated difficult matrix introduction (DMI) for identification of residues of washing powder on clothing with GC-MS and a LINer EXchanger (LINEX)
|Shimadzu|Applications
Application Note No. 103 (April 2006) Automated difficult matrix introduction (DMI) for identification of residues of washing powder on clothing with GC-MS and a LINer EXchanger (LINEX) Key Words: Automated Difficult Matrix Introduction (DMI)* GC-MS Allergens, fragrances Washing powder Erwin…
Key words
dmi, dmiwashing, washingpowder, powderclothing, clothingcotton, cottonresidue, residuelinex, linexatas, atasalmost, almostmatrix, matrixsample, sampleliner, linerwashed, washedvolatile, volatilewhole
Automated difficult matrix introduction (DMI) for identification of allergens and fragrances in shampoo with GC-MS-Olfactometry and a liner exchanger (LINEX)
|Shimadzu|Applications
Application Note No. 101 (February 2006) Automated difficult matrix introduction (DMI) for identification of allergens and fragrances in shampoo with GC-MS-Olfactometry and a liner exchanger (LINEX) Key Words: Automated sample preparation Difficult matrix introduction (DMI) GC-MS-olfactrometry Allergens, fragrances Shampoo Erwin…
Key words
shampoo, shampoodmi, dmilinex, linexatas, atasolfactrometry, olfactrometryinternational, internationaldifficult, difficultexchanger, exchangercompounds, compoundssmelly, smellytetradecanol, tetradecanolautomated, automatedphaser, phasershampoos, shampoosmatrix
Automated DMI for screening of cosmetic products
2006|Shimadzu|Applications
*NEWS 01.2006 GB 10.03.2006 11:11 Uhr Seite 7 APPLICATION Shimadzu News 1/2006 Automated DMI for scree nin cosmetic products GC/MS GC/MS is also coupled to a sniffing port (‘PHASER’). At the end of the GC column the carrier gas flow…
Key words
dmi, dmiatas, atascosmetic, cosmeticglycol, glycolamsterdam, amsterdaminternational, internationalcompounds, compoundsint’l, int’ltriehtylene, triehtyleneproducts, productsrefocussed, refocussedscree, screescreening, screeningheptaethylene, heptaethylenemonododecyl
Screening and identification of several toxic additives in tobacco using automated difficult matrix introduction (DMI) and GC-MS with a LINer EXchanger (LINEX)
|Shimadzu|Applications
Application Note No. 104 (dec 2006) Screening and identification of several toxic additives in tobacco using automated difficult matrix introduction (DMI) and GC-MS with a LINer EXchanger (LINEX) Key Words: Automated Difficult Matrix Introduction (DMI)* GC-MS additives tobacco Erwin Kaal,…
Key words
dmi, dmitobacco, tobaccolinex, linexatas, atasmarlboro, marlborodegradate, degradatedrum, drumadditives, additivesinternational, internationalliner, linerknows, knowsdifficult, difficultpink, pinkseveral, severalgovernment