GC Column Solvent Retention Table
Technical notes | 2014 | Agilent TechnologiesInstrumentation
Gas chromatography (GC) retention data for common solvents and their impurities is essential for laboratories engaged in chemical analysis, quality control and regulatory compliance. Detailed retention tables enable analysts to quickly identify contaminants in bulk solvents, select the most suitable column chemistry for separation and ensure reproducible results across diverse applications.
This technical overview presents a relative retention order for 275 solvent compounds on three Agilent GC columns: DB-1 (non-polar), DB-624 (medium polarity) and DB-WAX (polar). The main goal is to provide comprehensive reference data to facilitate impurity screening in bulk solvents and guide column selection based on analyte polarity and functional groups.
The study employed a standardized GC–FID method under constant pressure helium flow. Key experimental parameters included:
The retention table reveals clear trends in analyte behavior across the three column chemistries:
These retention patterns support rapid method development by matching analyte polarity with column selectivity, improving peak resolution and reducing analysis time.
The retention table and methodology offer several advantages for analytical laboratories:
Advances in GC technology and data analytics will further enhance solvent impurity analysis:
This solvent retention table for Agilent DB-1, DB-624 and DB-WAX columns provides a valuable resource for impurity detection, method development and column selection in solvent analysis. By offering reliable retention order data under standardized GC–FID conditions, the study supports efficient quality control workflows and consistent analytical performance.
No external literature references were cited in the original technical overview.
GC
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Gas chromatography (GC) retention data for common solvents and their impurities is essential for laboratories engaged in chemical analysis, quality control and regulatory compliance. Detailed retention tables enable analysts to quickly identify contaminants in bulk solvents, select the most suitable column chemistry for separation and ensure reproducible results across diverse applications.
Objectives and Overview of the Study
This technical overview presents a relative retention order for 275 solvent compounds on three Agilent GC columns: DB-1 (non-polar), DB-624 (medium polarity) and DB-WAX (polar). The main goal is to provide comprehensive reference data to facilitate impurity screening in bulk solvents and guide column selection based on analyte polarity and functional groups.
Methodology and Instrumentation
The study employed a standardized GC–FID method under constant pressure helium flow. Key experimental parameters included:
- Columns
• DB-624: 30 m × 0.53 mm ID × 3 µm film thickness
• DB-1: 30 m × 0.53 mm ID × 3 µm film thickness
• DB-WAX: 30 m × 0.53 mm ID × 1 µm film thickness - Carrier gas: Helium at constant pressure (~30 cm/s linear velocity at 40 °C for DB-624/DB-1; 34 cm/s for DB-WAX)
- Oven temperature program: 40 °C hold for 5 min; ramp to 260 °C at 10 °C/min; final hold (3 min for DB-624 and DB-1, 7 min for DB-WAX at 230 °C)
- Injection: Split mode (1:10), injector temperature 250 °C
- Detection: Flame ionization detector (FID) at 300 °C
Main Results and Discussion
The retention table reveals clear trends in analyte behavior across the three column chemistries:
- Non-polar analytes (e.g., alkanes, chlorinated solvents) elute earliest on DB-1 and DB-624, with shorter retention on DB-WAX.
- Polar compounds (e.g., diols, glycols, alcohols) exhibit significantly longer retention on the polar DB-WAX column, reflecting strong hydrogen bonding and polarity interactions.
- Intermediate polarity solvents (e.g., esters, ketones) show graded retention: DB-624 often provides optimal resolution due to moderate polarity, whereas DB-1 may elute some later.
- Functional group selectivity: aromatic and nitro-compounds maintain high retention across all phases but differ subtly in elution order, aiding in selective impurity profiling.
These retention patterns support rapid method development by matching analyte polarity with column selectivity, improving peak resolution and reducing analysis time.
Benefits and Practical Applications of the Method
The retention table and methodology offer several advantages for analytical laboratories:
- Streamlined impurity screening: Predefined retention windows accelerate peak identification in solvent QC.
- Column selection guidance: Data-driven choice of non-polar, medium-polarity or polar phases based on analyte classes.
- Reproducibility: Standardized GC conditions and Agilent column performance ensure consistent retention across labs.
- Method transferability: Retention order data can be integrated into spectral libraries and automated reporting systems.
Future Trends and Potential Applications
Advances in GC technology and data analytics will further enhance solvent impurity analysis:
- Retention index prediction using machine learning models to anticipate separation performance before analysis.
- Two-dimensional GC (GC×GC) coupling for ultra-high resolution of complex solvent matrices.
- Micro- and nano-bore columns with rapid temperature programming for high-throughput screening.
- Integration with real-time mass spectrometry detectors to combine retention and spectral data in a single run.
Conclusion
This solvent retention table for Agilent DB-1, DB-624 and DB-WAX columns provides a valuable resource for impurity detection, method development and column selection in solvent analysis. By offering reliable retention order data under standardized GC–FID conditions, the study supports efficient quality control workflows and consistent analytical performance.
References
No external literature references were cited in the original technical overview.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent GC AND GC/MS - Columns Applications Catalog
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
suggested, suggestedsupplies, suppliesethyl, ethylxylene, xyleneacetate, acetatemin, minmethyl, methylether, etherbhc, bhctime, timebutyl, butylendosulfan, endosulfanendrin, endrinalcohol, alcoholbutylbenzene
Residual solvents in pharmaceuticals
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications R id l solvents Residual l t in i pharmaceuticals h ti l Data No. GA123-0850 180000 160000 140000 66 64 56 120000 63 58+59 100000 Acetone 80000 60000 40000 20000 0 0 アセトン…
Key words
alcohol, alcoholbutyl, butylmethyl, methylether, etherketone, ketoneethyl, ethylacetate, acetatepropyl, propylisopropyl, isopropylcellosolve, cellosolveacetic, aceticキシレン, キシレンester, esterisobutyl, isobutylacid
Zebron ZB-WAXPLUS™ - Breaking The Mold For WAX GC Columns
2016|Phenomenex|Brochures and specifications
ZB-WAXPLUS ™ Breaking The Mold For WAX GC Columns • 100 % aqueous stability • Enhanced resolution • Better reproducibility www.phenomenex.com/WAXplus Introducing the BOLDER Side of GC Designed to move beyond the conventional to the exceptional, Zebron GC columns come…
Key words
waxplus, waxpluszebron, zebronphenomenex, phenomenexether, etherglycol, glycolglenfiddich, glenfiddichfid, fidmin, minethyl, ethylwax, waxphases, phasesbutyl, butylpolyethylene, polyethyleneyour, yourindustrial
Organic Solvents
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Organic Solvents Data No. GA138-0644 120000 27+28+29 100000 13+14 80000 60000 21 10 6 40000 2 34 1 5 20000 Acetone 0 0 24 26 17 11 7 8 9 12 15 16 20…
Key words
acetate, acetateglycol, glycolcellosolve, cellosolveether, ethermonomethyl, monomethylmethyl, methylalcohol, alcoholethyl, ethylbutyl, butylester, esteracetic, aceticキシレン, キシレンpropylene, propylenemonoethyl, monoethylisobutyl