GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Shimadzu GC Driver for OpenLab CDS - Brevis™ GC-2050

Technical notes | 2023 | ShimadzuInstrumentation
GC, Software
Industries
Manufacturer
Agilent Technologies, Shimadzu

Summary

Importance of Topic

The Shimadzu GC Driver for Agilent OpenLab CDS enables seamless integration of Shimadzu gas chromatography systems into a leading data acquisition platform, addressing the growing demand for consolidated software control in busy analytical labs.

Objectives and Overview

This document describes the development and features of a universal Shimadzu GC Driver compatible with Agilent OpenLab CDS and EZChrom, supporting easy control of multiple Shimadzu GC models—particularly the compact Brevis GC-2050—through a single software interface.

Used Instrumentation

  • Brevis GC-2050 with AOC-30i autosampler
  • Nexis GC-2030 system
  • GC-2010/GC-2014 series GCs
  • AOC-20i/AOC-20s autosamplers and HS-10/HS-20 headspace samplers
  • Optional detectors: FID, TCD, ECD, FPD, FTD, BID, SCD
  • Accessories: gas selector, auxiliary temperature controllers, digital control boards


Methodology and Key Features

The driver software interfaces with OpenLab CDS 2.5–2.7 and OpenLab EZChrom A.04.10, enabling:

  • Remote instrument control and real-time status monitoring
  • Easy sTop function to automate inlet cooling and liner replacement via a single button on both the instrument panel and within OpenLab
  • Helium conservation through automatic carrier gas switching with an optional gas selector
  • Built-in hydrogen leak detection for enhanced safety and automatic shutdown in case of gas leaks


Main Results and Discussion

Deployment of the driver achieved a 35% reduction in benchtop footprint with the Brevis GC-2050 compared to traditional models, without compromising analytical performance. The Easy sTop maintenance feature streamlined daily workflows, reducing downtime. Automated gas switching and leak detection improved lab safety and minimized helium consumption.

Benefits and Practical Applications

  • Space-efficient GC installations in constrained lab environments
  • Unified control interface for multiple GC models
  • Cost savings from reduced helium use and maintenance effort
  • Increased operational safety via hydrogen monitoring and automatic shutdown


Future Trends and Potential Applications

Advancements in IoT, M2M communication, and AI-driven diagnostics are expected to enhance self-optimizing GC workflows, reduce dependence on operator expertise, and further improve uptime and data consistency for routine and demanding analyses.

Conclusion

The Shimadzu GC Driver for Agilent OpenLab delivers a versatile solution for consolidating multi-vendor GC systems under a single software platform. Its compact design, maintenance support, and gas saving functions offer clear advantages for modern analytical laboratories.

Reference

No external literature references were cited.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Shimadzu GC Driver for Waters Empower (Brevis™ GC-2050)
C180-E086B Enables the Brevis™ GC-2050 to be Controlled by Waters™ Empower™ Shimadzu GC Driver for Waters Empower Brevis™ GC-2050 Nexis™ GC-2030 Enables Control of the Brevis GC-2050, a System that Offers Uncompromised Analytical Performance in a Small Footprint The compact…
Key words
controller, controllerswitchover, switchoverunit, unitgas, gasadditional, additionalhydrogen, hydrogenanalysis, analysisoptions, optionssequence, sequencesaving, savingsensor, sensorclick, clickcarrier, carriertemperature, temperaturecontrollable
Shimadzu GC Driver for Chromeleon 7
Shimadzu GC Driver for Chromeleon 7
2023|Thermo Fisher Scientific|Others
C180-E089C Enables the Brevis™ GC-2050 to be Controlled by Thermo Scientific™ Dionex™ Chromeleon™ 7 Shimadzu GC Driver for Chromeleon 7 Brevis™ GC-2050 Nexis™ GC-2030 Enables Control of the Brevis GC-2050, a System that Offers Uncompromised Analytical Performance in a Small…
Key words
controller, controllerswitchover, switchoverunit, unitgas, gashydrogen, hydrogenoptions, optionsanalysis, analysissequence, sequencesaving, savingsensor, sensorclick, clickadditional, additionalcarrier, carrierdevice, deviceautomatic
Shimadzu GC Driver for OpenLAB CDS
Shimadzu GC Driver for OpenLAB CDS
2019|Agilent Technologies|Others
C180-E091 Nexis™ SCD-2030 can now be controlled from Agilent OpenLAB Shimadzu GC Driver for OpenLAB CDS Shimadzu Nexis SCD-2030 sulfur chemiluminescence detection systems can now be controlled from Agilent’s OpenLAB Chromatography Data System. The Nexis SCD-2030 is a next-generation system…
Key words
openlab, openlabcontroller, controllercds, cdsezchrom, ezchromadditional, additionaledition, editionoptions, optionsdriver, driverunit, unitauxiliary, auxiliarytemperature, temperatureworld, worldcontrollable, controllablelineup, lineupequimolar
Shimadzu GC Driver Ver. 2 for OpenLAB CDS
Shimadzu GC Driver Ver. 2 for OpenLAB CDS
2017|Agilent Technologies|Others
C180-E087 Nexis GC-2030 Can Now Be Controlled from Agilent OpenLAB Shimadzu GC Driver Ver. 2 for OpenLAB CDS Shimadzu Nexis GC-2030 gas chromatographs can now be controlled from Agilent OpenLAB CDS (chromatography data system). The Nexis GC-2030, which provides the…
Key words
controller, controllerpanel, panelezchrom, ezchromcontrol, controladditional, additionaledition, editionoptions, optionsunit, unitshimadzu, shimadzuopenlab, openlabauxiliary, auxiliaryunits, unitstemperature, temperaturecds, cdsflow
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike