Agilent AI Peak Integration for MassHunter
Technical notes | 2023 | Agilent TechnologiesInstrumentation
In modern testing laboratories, regulatory demands and customer expectations require rapid and highly accurate quantification of trace compounds. Phthalate analysis in consumer products presents challenges due to isomeric mixtures, broad peak shapes, and manual integration variability. Introducing AI-driven integration addresses these challenges by improving consistency, reducing human error, and accelerating data processing workflows.
This study presents Agilent AI Peak Integration for MassHunter, an AI-powered plug-in designed to replicate expert manual GC/MS peak integration. The tool aims to enhance quantitation precision for phthalates, decrease manual reintegration effort, and seamlessly integrate into existing MassHunter workflows. It outlines the development, training, and validation of a machine learning model and demonstrates performance gains over default parameter-less integration methods.
The development of the AI integration model followed a multi-stage approach:
The AI integration model surpassed the default MassHunter integrator when reaching predefined performance thresholds. Key findings include:
AI integration tools are expected to expand beyond phthalates to a wider range of analytes as training datasets grow. Future developments may include real-time adaptive integration during analysis, integration of additional chromatographic and spectral features, and on-premises deployment options for labs requiring local processing. Advanced user feedback loops and federated learning could further refine model robustness across diverse laboratories.
Agilent AI Peak Integration for MassHunter demonstrates that machine learning can closely mimic expert manual integration, offering improved quantitation accuracy, workflow efficiency, and regulatory traceability. By leveraging cloud-based training and a user-adaptive framework, this tool represents a significant advancement in automated GC/MS data processing.
GC/MSD, Software
IndustriesMaterials Testing
ManufacturerAgilent Technologies
Summary
Significance of the Topic
In modern testing laboratories, regulatory demands and customer expectations require rapid and highly accurate quantification of trace compounds. Phthalate analysis in consumer products presents challenges due to isomeric mixtures, broad peak shapes, and manual integration variability. Introducing AI-driven integration addresses these challenges by improving consistency, reducing human error, and accelerating data processing workflows.
Objectives and Study Overview
This study presents Agilent AI Peak Integration for MassHunter, an AI-powered plug-in designed to replicate expert manual GC/MS peak integration. The tool aims to enhance quantitation precision for phthalates, decrease manual reintegration effort, and seamlessly integrate into existing MassHunter workflows. It outlines the development, training, and validation of a machine learning model and demonstrates performance gains over default parameter-less integration methods.
Methodology
The development of the AI integration model followed a multi-stage approach:
- Practitioner Interviews: Collected expert insights on manual integration protocols and peak identification challenges for phthalates.
- Data Collection: Generated a diverse annotated dataset using MassHunter’s default integrator and manual integrations on consumer-product samples.
- Feature Extraction: Captured chromatographic parameters, retention times, spectral patterns, and peak shape metrics as input variables.
- Model Development: Adapted state-of-the-art machine learning frameworks to the GC/MS integration task and iteratively optimized hyperparameters.
- Training and Validation: Split data into training, validation, and test subsets to teach the model manual integration practices and ensure unbiased performance assessment.
- Quality Control: Employed outlier filtering, normalization, and continuous monitoring of performance metrics to safeguard model reliability.
Instrumentation Used
- Agilent Gas Chromatograph/Mass Selective Detector (GC/MSD)
- Agilent MassHunter Quantitative Analysis software with AI Plug-in
- Cloud-based GPUs for scalable model training
Main Results and Discussion
The AI integration model surpassed the default MassHunter integrator when reaching predefined performance thresholds. Key findings include:
- Quantitation Accuracy: Significant reduction in mean and median error of peak areas compared to manual integration benchmarks.
- Peak Screening Metrics: Continuous improvement in Critical Success Index, Positive Predictive Value, and Negative Predictive Value over iterative training cycles.
- Reproducibility: Consistent results across technicians and laboratories, enabling retrospective data reprocessing tied to specific model versions.
Benefits and Practical Applications
- Enhanced consistency and precision in quantitative analysis of phthalates and other compounds.
- Reduced training requirements and manual workload for laboratory personnel.
- Auditable model version control and traceability for regulated environments.
- Scalable cloud-based deployment allowing seamless updates and maintenance.
Future Trends and Possibilities
AI integration tools are expected to expand beyond phthalates to a wider range of analytes as training datasets grow. Future developments may include real-time adaptive integration during analysis, integration of additional chromatographic and spectral features, and on-premises deployment options for labs requiring local processing. Advanced user feedback loops and federated learning could further refine model robustness across diverse laboratories.
Conclusion
Agilent AI Peak Integration for MassHunter demonstrates that machine learning can closely mimic expert manual integration, offering improved quantitation accuracy, workflow efficiency, and regulatory traceability. By leveraging cloud-based training and a user-adaptive framework, this tool represents a significant advancement in automated GC/MS data processing.
References
- Wujek, B. (2016). Best Practices for Machine Learning Applications. SAS Institute.
- Smith, L. N. (2017). Best Practices for Applying Deep Learning to Novel Applications.
- Zinkevich, M. Rules of Machine Learning: Best Practices for ML Engineering. Retrieved from martin.zinkevich.org/rules_of_ml/rules_of_ml.pdf.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent AI Peak Integration for GC/MS Analysis of Phthalates
2024|Agilent Technologies|Applications
Application Note Consumer Products Agilent AI Peak Integration for GC/MS Analysis of Phthalates Authors Ruoji Luo, Tamas King, Winnie Chau, Thomas Bispham Agilent Technologies, Inc. Abstract Gas chromatography/mass spectrometry (GC/MS) data analysis is often manual, time consuming, and human reliant.…
Key words
integration, integrationmodel, modelpeak, peaktrained, trainedphthalates, phthalatesintegrator, integratorintegrations, integrationspredictions, predictionsincorrectly, incorrectlymasshunter, masshuntermachine, machinelearning, learningbispham, bisphamnegative, negativewell
AI Peak Integration for MassHunter software automates manual peak integration during the data analysis process in GC/SQ
2023|Agilent Technologies|Posters
Poster Reprint ASMS 2023 Poster number TP 062 AI Peak Integration for MassHunter software automates manual peak integration during the data analysis process in GC/SQ Thomas Bispham, Tamas King, Winnie Chau, and Ruoji Luo Agilent Technologies, Inc. Introduction GC/MS data…
Key words
integration, integrationlearning, learningmanual, manualmachine, machinepeak, peakbatch, batchmodel, modelphthalate, phthalatedinp, dinpdata, datachemist, chemistadd, addautomates, automatescompounds, compoundsvaluably
Comprehensive machine learning prediction of GC/MS pesticide recovery based on the molecular fingerprinting for food QA/QC
2019|Agilent Technologies|Posters
Poster Reprint ASMS 2019 TP298 Comprehensive machine learning prediction of GC/MS pesticide recovery based on the molecular fingerprinting for food QA/QC Takeshi Serino* 1,2; Sadao Nakamura1; Yoshizumi Takigawa1; Norton Kitagawa3; Shigehiko Kanaya 2 1 Agilent Technologies, Hachioji City, Japan 2…
Key words
learning, learningmachine, machine𝑖𝑗, 𝑖𝑗descriptor, descriptorsmiles, smilesrecovery, recoverypek, pekgeneralization, generalizationatoms, atomspesticide, pesticideprediction, predictionpesticides, pesticidesmethods, methodsindex, index𝑦ത
MassHunter Quantitative Analysis Webinar Series - High Throughput Quantitative Analysis
2018|Agilent Technologies|Presentations
High Throughput Quantitative Analysis MassHunter Quantitative Analysis Webinar Series Howard Sanford Stephen Harnos With Tom Barrett & Matt Leyden & Kevin Costalunga 1 High Throughput Quantitative Analysis MassHunter Quantitative Analysis Software Review and Quant Method Optimization What is quantitative analysis?…
Key words
throughput, throughputquantitative, quantitativeoutliers, outliershigh, highanalysis, analysisreview, reviewoutlier, outlierintegrators, integratorsfilter, filterretention, retentionreference, referencecompound, compoundsetup, setupwindow, windowpeak