An Optimization Tool for MS Signal Acquisition in GC Triple Quadrupole Mass Spectrometry
Posters | 2019 | Agilent TechnologiesInstrumentation
Gas chromatography coupled with triple quadrupole mass spectrometry (GC-MS/MS) in multiple reaction monitoring (MRM) mode is a gold standard for achieving high sensitivity and selectivity in trace analysis of complex matrices. Developing optimized MRM transitions manually is time-consuming and prone to errors, particularly when dealing with co-eluting compounds and matrix interferences. An automated optimization tool addresses these challenges by streamlining method development and improving data quality.
This work presents a modular software optimizer designed for Agilent 7000 and 7010 series GC triple quadrupole instruments. The optimizer automates all key steps of MRM transition development—from precursor ion identification through collision energy optimization—and can operate in fully automated or user-guided modes.
The optimizer integrates seamlessly with Agilent MassHunter GC/MS Data Acquisition software (v10.0) and offers the following automated modules:
In a case study using the environmental contaminant fenarimol (precursor m/z 295), the optimizer deconvoluted scan data to identify potential precursors and conducted product ion scans at collision energies of 5, 15, 25, and 35 eV. Automated selection of the top fragment ions (m/z 139, 111, 183) was followed by targeted collision energy optimization. Signal-intensity versus collision energy plots demonstrated clear maxima, confirming the tool’s ability to refine CE settings and improve sensitivity.
The optimizer enhances laboratory efficiency by reducing manual intervention and enabling rapid method development for:
Future enhancements may include machine learning-driven prediction of optimal transitions and collision energies based on compound structure, cloud-based sharing of optimized methods to improve reproducibility across laboratories, and real-time online optimization for high-throughput screening workflows.
The presented GC triple quadrupole optimizer delivers a flexible, user-friendly solution for automated MRM method development. It significantly accelerates the transition from initial scan data to fully optimized MRM acquisition methods, while ensuring high analytical performance and reproducibility.
Anastasia Andrianova; Melissa Churley. An Optimization Tool for MS Signal Acquisition in GC Triple Quadrupole Mass Spectrometry. Poster TP305, ASMS 2019, Agilent Technologies Inc., Wilmington, DE and Santa Clara, CA, USA, June 2, 2019.
GC/MSD, GC/MS/MS, GC/QQQ
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Gas chromatography coupled with triple quadrupole mass spectrometry (GC-MS/MS) in multiple reaction monitoring (MRM) mode is a gold standard for achieving high sensitivity and selectivity in trace analysis of complex matrices. Developing optimized MRM transitions manually is time-consuming and prone to errors, particularly when dealing with co-eluting compounds and matrix interferences. An automated optimization tool addresses these challenges by streamlining method development and improving data quality.
Objectives and Study Overview
This work presents a modular software optimizer designed for Agilent 7000 and 7010 series GC triple quadrupole instruments. The optimizer automates all key steps of MRM transition development—from precursor ion identification through collision energy optimization—and can operate in fully automated or user-guided modes.
Methodology and Instrumentation
The optimizer integrates seamlessly with Agilent MassHunter GC/MS Data Acquisition software (v10.0) and offers the following automated modules:
- Spectral deconvolution to detect precursor ions even in the presence of interferences
- Product ion scanning at up to four collision energy values per precursor
- Selection of optimal precursor and product ions based on abundance, m/z spacing, and cluster rules
- Collision energy optimization to maximize signal intensity for each selected transition
- Generation of time-segmented or dynamic MRM (dMRM) acquisition methods
Instrumentation Used
- Agilent 7890 GC with 7000/7010 Triple Quadrupole MS
- Agilent MassHunter GC/MS Data Acquisition software version 10.0
- Standard GC solvent delay, gain, and tune files supplied with the system
Main Results and Discussion
In a case study using the environmental contaminant fenarimol (precursor m/z 295), the optimizer deconvoluted scan data to identify potential precursors and conducted product ion scans at collision energies of 5, 15, 25, and 35 eV. Automated selection of the top fragment ions (m/z 139, 111, 183) was followed by targeted collision energy optimization. Signal-intensity versus collision energy plots demonstrated clear maxima, confirming the tool’s ability to refine CE settings and improve sensitivity.
Benefits and Practical Applications
The optimizer enhances laboratory efficiency by reducing manual intervention and enabling rapid method development for:
- New TQ users transitioning from scan or SIM workflows to MRM
- Existing users converting legacy methods or re-optimizing collision energies after hardware or column changes
- High-throughput creation of MRM methods for novel analytes in environmental, pharmaceutical, and food testing
Future Trends and Potential Applications
Future enhancements may include machine learning-driven prediction of optimal transitions and collision energies based on compound structure, cloud-based sharing of optimized methods to improve reproducibility across laboratories, and real-time online optimization for high-throughput screening workflows.
Conclusion
The presented GC triple quadrupole optimizer delivers a flexible, user-friendly solution for automated MRM method development. It significantly accelerates the transition from initial scan data to fully optimized MRM acquisition methods, while ensuring high analytical performance and reproducibility.
Reference
Anastasia Andrianova; Melissa Churley. An Optimization Tool for MS Signal Acquisition in GC Triple Quadrupole Mass Spectrometry. Poster TP305, ASMS 2019, Agilent Technologies Inc., Wilmington, DE and Santa Clara, CA, USA, June 2, 2019.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Automated MRM Method Development for Pesticides in Cannabis Using the Agilent MassHunter Optimizer for GC/TQ
2020|Agilent Technologies|Applications
Application Note Cannabis & Hemp Testing Automated MRM Method Development for Pesticides in Cannabis Using the Agilent MassHunter Optimizer for GC/TQ Authors Anastasia Andrianova, He Liu, and Alex Graettinger Agilent Technologies, Inc. Abstract This application note demonstrates the use of…
Key words
collision, collisionmrm, mrmcannabis, cannabisprecursor, precursorenergies, energiesions, ionstransitions, transitionsoptimization, optimizationion, ionproduct, productenergy, energyidentification, identificationoptimizer, optimizerscan, scandeveloped
Automated MRM Method Development for US EPA Method 8270 with the Agilent MassHunter Optimizer for GC/TQ
2020|Agilent Technologies|Applications
Application Note Environmental Automated MRM Method Development for US EPA Method 8270 with the Agilent MassHunter Optimizer for GC/TQ Authors Anastasia Andrianova, He Liu, Alex Graettinger, and Melissa Churley Agilent Technologies, Inc. Abstract This application note demonstrates the use of…
Key words
mrm, mrmcollision, collisionsim, simstart, startions, ionsoptimization, optimizationproduct, productenergy, energyion, ionprecursor, precursorscan, scanoptimizer, optimizerfrom, fromenergies, energiesmrms
Agilent MassHunter Optimizer - Quick Start Guide
2018|Agilent Technologies|Manuals
Agilent MassHunter Optimizer Automated MS Method Development Software Quick Start Guide What is MassHunter Optimizer? 2 Startup 4 User Interface 5 Menus and Toolbar 6 Compound Setup Tab 9 Precursor Ion Selection Tab 9 Product Ion Selection Tab 9 Optimizer…
Key words
optimizer, optimizermasshunter, masshunteroptimization, optimizationguide, guidestart, startimport, importquick, quickdatabase, databasesequences, sequencesselect, selectbrowser, browsercompounds, compoundscompound, compoundsetting, settingions
A Triple Quadrupole GC/MS MRM Database for Forensic and Toxicological Workflows
2024|Agilent Technologies|Posters
Poster Reprint ASMS 2024 Poster number WP 810 A Triple Quadrupole GC/MS MRM Database for Forensic and Toxicological Workflows Celine Gys1, Anna Klimowska1,2, Adrian Covaci1, Remko van Loon3, Joel Ferrer4, Anastasia Andrianova4 1Toxicological Center, University of Antwerp, Wilrijk, Belgium; 2Department…
Key words
database, databaseforensic, forensicmrm, mrmtoxicological, toxicologicaltoxicants, toxicantsacquisition, acquisitiondetected, detectedtransitions, transitionsoptimizer, optimizermasshunter, masshunterauthentic, authenticdmrm, dmrmtemperature, temperatureretention, retentionexercising