SLB™-5ms Fast GC Columns for Semivolatile Analysis

Applications |  | MerckInstrumentation
GC/MSD, GC columns, Consumables
Industries
Environmental
Manufacturer
Merck

Summary

Importance of the Topic


Semivolatile organic compounds are widespread environmental contaminants that require accurate quantification to assess human health and ecological risks. US EPA Method 8270 provides a benchmark for GC-MS analysis, but traditional run times limit laboratory throughput and increase operational costs.

Objectives and Overview


This study compares two SLB-5ms capillary columns with different inner diameters (0.25 mm vs. 0.18 mm) under EPA Method 8270 conditions. The aim is to demonstrate how narrow-bore, shorter columns can accelerate semivolatile analysis while maintaining full compound resolution.

Methodology and Instrumentation


An 86-component standard (72 analytes, 8 surrogates, 6 internal standards) was injected onto:
  • A 30 m×0.25 mm I.D., 0.25 µm SLB-5ms column: 40 °C (2 min), 22 °C/min to 240 °C, 10 °C/min to 330 °C (1 min); helium at 1.0 mL/min; splitless injection.
  • A 20 m×0.18 mm I.D., 0.18 µm SLB-5ms column: 40 °C (0.7 min), 55 °C/min to 240 °C, 28 °C/min to 330 °C (2 min); helium at 40 cm/s constant flow; 10:1 split injection.

Main Results and Discussion


The 0.25 mm column delivered a 19.6 min run with full separation of all 86 targets. Switching to the 0.18 mm column reduced the analysis to 8.1 min—an 11+ min saving—while preserving mass spectral resolution and compound identification. This time reduction enables approximately 14 additional injections during each 12 h tuning window.

Benefits and Practical Applications


  • Enhanced sample throughput without investment in additional instruments.
  • Lower labor and operational costs through faster GC-MS cycles.
  • Compliance with EPA 8270 performance criteria maintained.
  • Suitable for high-volume environmental, QA/QC, and industrial laboratories.

Future Trends and Opportunities


Ongoing developments in ultra-narrow bore columns and new stationary phases will further shorten analysis times and boost resolution. Coupling Fast GC with automated sample preparation, real-time data analytics, and machine-learning-driven method optimization promises to revolutionize high-throughput environmental monitoring.

Conclusion


Fast GC using 0.18 mm I.D. SLB-5ms columns significantly increases semivolatile analysis throughput under EPA 8270 guidelines without sacrificing data quality. This approach offers an efficient, cost-effective solution for laboratories seeking to maximize productivity.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Fast GC - Increase GC Speed Without Sacrificing Resolution
Fast GC - Increase GC Speed Without Sacrificing Resolution
2015|Merck|Brochures and specifications
Fast GC Increase GC Speed Without Sacrificing Resolution Increase Productivity Utilize Resources More Effectively Achieve Quicker Turn-Around Times Analyze More Samples Fast GC | Increase GC Speed Without Sacrificing Resolution Overview Shorter analysis times allow increased sample throughput, which translates…
Key words
sacrificing, sacrificingfast, fasttrifluoromethylsulfonyl, trifluoromethylsulfonylmin, minincrease, increasebenzo, benzoimide, imidephthalate, phthalateresolution, resolutionfluoranthene, fluoranthenespeed, speedlimonene, limonenebhc, bhcbis, bisneral
Special Purpose SLB™-5ms Capillary GC Columns
595 North Harrison Road Bellefonte, PA 16823-0048 USA Telephone 800-247-6628  814-359-3441 Fax 800-447-3044  814-359-3044 email: [email protected] sigma-aldrich.com/supelco Product Information Special Purpose SLB™ -5ms Capillary GC Columns A Non-Polar Column for Trace Analyses Low levels of detection are a…
Key words
fused, fuseddeactivation, deactivationphthalate, phthalatesilica, silicacolumn, columnbenzo, benzopolar, polarglasseal, glassealguard, guardbutt, butttubing, tubingfluoranthene, fluoranthenetapered, taperedcapillary, capillarychemists
Fast GC-MS Analysis of US EPA Method 8270D Semivolatiles Using Supelco SLB-5ms
Application Report 474 Fast GC-MS Analysis of US EPA Method 8270D Semivolatiles Using Supelco SLB-5ms US EPA Method 8270D specifies a procedure for the determination of semivolatiles in solid waste and ground water samples. The long list of analytes includes…
Key words
phthalate, phthalatebenzo, benzofluoranthene, fluorantheneanthracene, anthracenepyrene, pyrenebutylbenzyl, butylbenzylnitrosodiphenylamine, nitrosodiphenylaminecarbazole, carbazoleazobenzene, azobenzenedibenzofuran, dibenzofuranbenzidine, benzidinepropylamine, propylaminehexachlorocyclopentadiene, hexachlorocyclopentadieneisophorone, isophoronenitroso
Fast Gas Chromatography - Increase GC Speed Without Sacrificing Resolution
Fast Gas Chromatography Increase GC Speed Without Sacrificing Resolution The life science business of Merck operates as MilliporeSigma in the U.S. and Canada. Overview Shorter analysis times allow increased sample throughput, which translates to the completion of more runs per…
Key words
oven, ovencarrier, carrierliner, linermin, mingas, gasinjection, injectioncolumn, columnlimonene, limonenemethylene, methylenechloride, chloridesample, samplephthalate, phthalateterpinene, terpineneneral, neralpinene
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike