Organic solvents
Applications | | GL SciencesInstrumentation
The analysis of residual organic solvents is a critical quality control measure in pharmaceuticals, environmental monitoring, and industrial processes. Accurate quantification of volatile compounds ensures product safety, regulatory compliance, and workplace safety by detecting trace levels of potentially hazardous solvents.
This application note demonstrates a rapid, reliable gas chromatographic method for separating and quantifying seventeen common organic solvents in air samples. Using an InertCap® 624 capillary column paired with a flame ionization detector (FID), the study evaluates chromatographic performance, peak resolution, and analysis time for routine solvent screening.
The method employs the following instrumentation and conditions:
All seventeen solvents—including alcohols (methanol, isopropanol), halogenated solvents (dichloromethane, chloroform), esters (ethyl acetate, butyl acetate), aromatics (toluene, xylenes, ethylbenzene), and ethers (1,4-dioxane)—were baseline separated within a 14-minute runtime. The InertCap 624 column provided sharp peak shapes, minimal tailing, and consistent retention times. Key observations:
This GC/FID approach offers high throughput, robust performance, and ease of use for routine residual solvent screening in pharmaceutical QA/QC labs, environmental monitoring stations, and industrial safety assessments. The method’s short runtime and broad analyte scope make it suitable for compliance with regulatory limits and rapid decision-making.
Advances may include coupling with mass spectrometric detection for enhanced specificity, automated headspace sampling to improve reproducibility, and miniaturized GC systems for on-site air monitoring. Integration with data analytics and machine learning could further streamline solvent pattern recognition and predictive maintenance of analytical instruments.
The presented GC/FID method using an InertCap 624 column provides a fast, accurate, and versatile solution for comprehensive residual solvent analysis. Its robust chromatographic performance and efficient separation make it an ideal choice for quality control and environmental safety applications.
No external literature sources were cited in this application note.
GC, GC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerGL Sciences
Summary
Importance of the Topic
The analysis of residual organic solvents is a critical quality control measure in pharmaceuticals, environmental monitoring, and industrial processes. Accurate quantification of volatile compounds ensures product safety, regulatory compliance, and workplace safety by detecting trace levels of potentially hazardous solvents.
Objectives and Study Overview
This application note demonstrates a rapid, reliable gas chromatographic method for separating and quantifying seventeen common organic solvents in air samples. Using an InertCap® 624 capillary column paired with a flame ionization detector (FID), the study evaluates chromatographic performance, peak resolution, and analysis time for routine solvent screening.
Methodology and Instrumentation
The method employs the following instrumentation and conditions:
- Gas chromatograph with FID detector
- Column: InertCap 624, 0.53 mm I.D. × 75 m, 3 µm film thickness
- Carrier gas: helium at 100 kPa
- Injection: split mode, 20 mL/min
- Temperature program: 60 °C initial, ramp at 10 °C/min to 200 °C
- Sample size: 0.5 mL air, solvent concentrations 10–40 ppm (Vol/Vol)
Main Results and Discussion
All seventeen solvents—including alcohols (methanol, isopropanol), halogenated solvents (dichloromethane, chloroform), esters (ethyl acetate, butyl acetate), aromatics (toluene, xylenes, ethylbenzene), and ethers (1,4-dioxane)—were baseline separated within a 14-minute runtime. The InertCap 624 column provided sharp peak shapes, minimal tailing, and consistent retention times. Key observations:
- Early-eluting alcohols resolved without interference.
- Halogenated solvents exhibited strong retention and clear separation from aliphatics.
- Aromatic compounds eluted in the latter half of the run with excellent peak symmetry.
Benefits and Practical Applications of the Method
This GC/FID approach offers high throughput, robust performance, and ease of use for routine residual solvent screening in pharmaceutical QA/QC labs, environmental monitoring stations, and industrial safety assessments. The method’s short runtime and broad analyte scope make it suitable for compliance with regulatory limits and rapid decision-making.
Future Trends and Potential Applications
Advances may include coupling with mass spectrometric detection for enhanced specificity, automated headspace sampling to improve reproducibility, and miniaturized GC systems for on-site air monitoring. Integration with data analytics and machine learning could further streamline solvent pattern recognition and predictive maintenance of analytical instruments.
Conclusion
The presented GC/FID method using an InertCap 624 column provides a fast, accurate, and versatile solution for comprehensive residual solvent analysis. Its robust chromatographic performance and efficient separation make it an ideal choice for quality control and environmental safety applications.
References
No external literature sources were cited in this application note.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Organic Solvents
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Organic Solvents Data No. GA138-0644 120000 27+28+29 100000 13+14 80000 60000 21 10 6 40000 2 34 1 5 20000 Acetone 0 0 24 26 17 11 7 8 9 12 15 16 20…
Key words
acetate, acetateglycol, glycolcellosolve, cellosolveether, ethermonomethyl, monomethylmethyl, methylalcohol, alcoholethyl, ethylbutyl, butylester, esterキシレン, キシレンacetic, aceticpropylene, propylenemonoethyl, monoethylisobutyl
Residual solvents in pharmaceuticals
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications R id l solvents Residual l t in i pharmaceuticals h ti l Data No. GA123-0850 180000 160000 140000 66 64 56 120000 63 58+59 100000 Acetone 80000 60000 40000 20000 0 0 アセトン…
Key words
alcohol, alcoholbutyl, butylmethyl, methylether, etherketone, ketoneethyl, ethylacetate, acetatepropyl, propylisopropyl, isopropylcellosolve, cellosolveキシレン, キシレンacetic, aceticester, esterisobutyl, isobutylacid
Organic solvents
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Organic solvents Data No. GA023-0850 14000 1 12000 10000 9 13 12 14 15 17 8000 6000 3 6 4 4000 11 2 78 10 166 5 19 18 2000 0 10 Acetic acid…
Key words
キシレン, キシレンacetate, acetatebutyl, butylalcohol, alcoholアニソール, アニソールテトラヒドロフラン, テトラヒドロフランヘプタン, ヘプタンethyl, ethylエチルベンゼン, エチルベンゼンアセトン, アセトンエタノール, エタノールanisole, anisoleacetic, aceticxylene, xyleneheptane
Organic solvents
|GL Sciences|Applications
InertSearch for GC TM InertCap® Applications Organic Solvents Data No. GA202-0410 40000 22 12+13 GC GA202 TC-BOND Q Methanol メタノール Methanol Methyl alcohol メタノール メチルアルコール 67-56-1 GC GA202 TC-BOND Q Ethanol エタノール Ethanol Ethyl alcohol エタノール エチルアルコール 64-17-5 GC GA202…
Key words
ヘキサン, ヘキサンuvolt, uvoltinertsearch, inertsearchinertcap, inertcapsolvebts, solvebtsブタノール, ブタノールenviroment, enviromentエチルエーテル, エチルエーテルジエチルエーテル, ジエチルエーテルメチルプロピルアルコール, メチルプロピルアルコールglycol, glycoltert, tertイソプロピルアセテート, イソプロピルアセテートテトラヒドロフラン, テトラヒドロフランポーラスポリマー