GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Simplified RMID Model Building

Technical notes | 2021 | MetrohmInstrumentation
RAMAN Spectroscopy
Industries
Materials Testing
Manufacturer
Metrohm

Summary

Significance of the Topic


Rapid and accurate material verification is essential in industries such as pharmaceuticals and fine chemicals to ensure product quality and regulatory compliance. Raman-based RMID (Raw Material Identification) tools enable non-destructive, on-site screening of active pharmaceutical ingredients (APIs) and excipients, reducing analysis time and labor.

Aims and Study Overview


This article examines the ModelExpert function within the Mira Cal P software, designed to automate and streamline chemometric model development for raw material verification. The study outlines how ModelExpert uses predefined data sets to identify optimal preprocessing and multivariate parameters without extensive manual intervention.

Methodology and Instrumentation


The workflow requires users to compile Training and Validation Sets of Raman spectra. ModelExpert then executes 192 combinations of preprocessing techniques (e.g., normalization, baseline correction) and principal component analysis settings. Performance is evaluated using receiver operating characteristic (ROC) curves and the area under the curve (AUC) metric, with penalties for false positive and negative rates. Instrumentation Details:
  • MIRA P Advanced handheld Raman spectrometer
  • High-efficiency spectrograph with Orbital-Raster-Scan (ORS) technology
  • Attachments: sample lens (laser class 3b) and vial holder (laser class 1)
  • Compliance: FDA 21 CFR Part 11

Main Results and Discussion


ModelExpert presents results in a summary popup and allows generation of a detailed PDF report with ROC curves, optimized parameters, and validation statistics. The automated approach reduces development time from days to minutes while maintaining robust discrimination between similar materials. Users can easily save and apply optimized models to routine analyses.

Benefits and Practical Applications


The automated parameter selection enables non-specialists to achieve reliable RMID models, facilitating rapid on-site screening in quality control environments. This reduces reliance on expert chemometricians and accelerates decision-making in production and QA/QC laboratories.

Future Trends and Possibilities of Use


Integration with additional machine learning algorithms, cloud-based model sharing, and expanded spectral libraries may further enhance versatility. Real-time process monitoring and adaptation of models to evolving material attributes represent promising directions for next-generation RMID tools.

Conclusion


ModelExpert within Mira Cal P offers a transparent, efficient, and user-friendly solution for building robust Raman-based material verification models. By automating parameter optimization and leveraging ROC-based evaluation, it democratizes RMID model development and supports stringent quality requirements.

Reference


Metrohm AG. AN-RS-031 Simplified RMID Model Building. Mira Cal P and ModelExpert. 2023.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Optimize raw material identification and verification (RMID) with MIRA P
Application Note AN-RS-044 Optimize raw material identification and verification (RMID) with MIRA P Validation model transfer increases productivity Using a verification model on multiple instruments shipment to be quickly released to production. expands a manufacturer’s raw material In most cases,…
Key words
mira, miramodel, modelvalidation, validationpackage, packagebasic, basicvariance, variancetransfer, transfermetrohm, metrohmverification, verificationrmid, rmidset, setincludes, includestraining, trainingmaterial, materialraw
Mira Cal P software - Tutorial
Mira Cal P software - Tutorial
2021|Metrohm|Manuals
Mira Cal P Tutorial 8.0105.8004EN / 2021-04-20 Metrohm AG Ionenstrasse CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com Mira Cal P Tutorial 8.0105.8004EN / 2021-04-20 Technical Communication Metrohm AG CH-9100 Herisau…
Key words
notice, noticemira, miratraining, trainingcal, calview, viewpassword, passwordwarning, warningset, setoperating, operatingsets, setssettings, settingsuser, userlibraries, librariescreating, creatingdanger
Transition RMID Operations Between Handheld Raman Devices
Application Note AN-RS-045 Transition RMID Operations Between Handheld Raman Devices Library and Model Transfer from NanoRam 785 to MIRA P For lab-quality results in non-traditional testing validated verification models already in routine use scenarios such as materials inspection at the…
Key words
mira, mirarmid, rmidverification, verificationmodel, modelpackage, packageraman, ramancsv, csvbasic, basicnanoram, nanoramnid, nididentification, identificationtransfer, transfertek, tekvalidation, validationlibrary
Metrohm MIRA Cal M Tutorial
Metrohm MIRA Cal M Tutorial
2021|Metrohm|Manuals
MIRA Cal M Tutorial 8.0105.8023EN / 2021-09-15 Metrohm Raman 407 South 2nd Street Laramie, WY 82070 USA +1 307 460 2089 [email protected] www.metrohm.com MIRA Cal M 2.XX or higher Tutorial 8.0105.8023EN / 2021-09-15 Technical Communication Metrohm Raman Laramie, WY 82070…
Key words
mira, mirawarning, warningcal, caldanger, dangernotice, noticeandroid, androidxtr, xtrtab, taboverview, overviewlibraries, librariesautofocus, autofocusdevice, devicesamples, samplesmenu, menusign
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike