Biodiesel Solutions
Applications | 2011 | RestekInstrumentation
As global energy demands rise and environmental regulations tighten, biodiesel has become a leading renewable alternative to petroleum diesel. Ensuring consistent quality and compliance with international standards is critical to prevent engine damage, reduce emissions, and maintain fuel performance. Advanced analytical methods for quantifying glycerin, fatty acid methyl esters (FAMEs), and residual methanol are essential to support reliable biodiesel production and quality control.
This study presents specialized gas chromatography (GC) solutions designed for biodiesel analysis. It evaluates fused silica and metal column technologies, integrated retention gaps, and complementary accessories to optimize performance for key biodiesel assays: total glycerin (ASTM D6584, EN 14105), FAME composition (EN 14103), and residual methanol (EN 14110). The aim is to demonstrate improved resolution, stability, and laboratory productivity.
Advances will likely focus on integrated column formats with extended temperature capabilities, automation of derivatization processes, coupling GC with mass spectrometry or tandem detection for comprehensive profiling, and portable or field-deployable GC systems for on-site biodiesel quality assessment. Continued innovation aims to further improve throughput, sensitivity, and sustainability of biodiesel analytics.
Selecting tailored GC columns, retention gaps, and accessories significantly enhances biodiesel quality testing by improving resolution, thermal stability, and laboratory efficiency. The combination of Rtx®-Biodiesel TG, MXT®-Biodiesel TG, Stabilwax®, and Rtx®-1 columns, along with supporting hardware, provides a complete solution for rigorous compliance with ASTM and European biodiesel standards.
GC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerRestek
Summary
Importance of the Topic
As global energy demands rise and environmental regulations tighten, biodiesel has become a leading renewable alternative to petroleum diesel. Ensuring consistent quality and compliance with international standards is critical to prevent engine damage, reduce emissions, and maintain fuel performance. Advanced analytical methods for quantifying glycerin, fatty acid methyl esters (FAMEs), and residual methanol are essential to support reliable biodiesel production and quality control.
Objectives and Study Overview
This study presents specialized gas chromatography (GC) solutions designed for biodiesel analysis. It evaluates fused silica and metal column technologies, integrated retention gaps, and complementary accessories to optimize performance for key biodiesel assays: total glycerin (ASTM D6584, EN 14105), FAME composition (EN 14103), and residual methanol (EN 14110). The aim is to demonstrate improved resolution, stability, and laboratory productivity.
Methodology and Instrumentation
- Categories of analysis: total glycerin (free and bound), FAME profiling, and methanol content.
- Derivatization reagent: N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) for glycerin and glycerides.
- Injection modes: cool on-column for glycerin and FAMEs, headspace injection for methanol.
- Temperature programs: ramp to 380 °C for glycerin/glyceride assays; 210–230 °C gradient for FAMEs; optimized headspace conditions for methanol.
Used Instrumentation
- Columns: Rtx®-Biodiesel TG (fused silica), MXT®-Biodiesel TG (metal), Stabilwax® (polar FAME analysis), Rtx®-1 (methanol headspace).
- Retention gaps: factory-coupled Alumaseal® and Integra-Gap® integrated retention gaps for enhanced inertness and leak-free operation.
- Connectors: MXT® low-dead-volume connectors and Siltek®-treated stainless steel tubing.
- Accessories: BTO® high-temperature septa, capillary ferrules (graphite and Vespel®/graphite), Siltek® FID jets, Parker Balston® PEM hydrogen generators, Restek electronic leak detector.
Main Results and Discussion
- Glycerin assay: Rtx®-Biodiesel TG columns with retention gaps achieved clear separation of free glycerin, mono-, di-, and triglycerides, meeting ASTM D6584/EN 14105 criteria.
- Column stability: Metal MXT®-Biodiesel TG columns maintained peak symmetry and low bleed after 100 cycles to 430 °C, outperforming high-temperature fused silica alternatives.
- FAME profiling: Stabilwax® column delivered baseline resolution of C14:0–C24:1 methyl esters in under 11 minutes with excellent symmetry and reproducibility (EN 14103).
- Methanol analysis: Rtx®-1 column effectively resolved residual methanol from interfering compounds in headspace assays (EN 14110).
Benefits and Practical Applications
- Enhanced analytical reliability reduces downtime and maintenance costs.
- Extended column lifetimes support high-temperature biodiesel methods.
- Integral retention gaps and inert connectors minimize leaks and sample degradation.
- Complete accessory suite ensures reproducible results and streamlined workflows.
Future Trends and Potential Applications
Advances will likely focus on integrated column formats with extended temperature capabilities, automation of derivatization processes, coupling GC with mass spectrometry or tandem detection for comprehensive profiling, and portable or field-deployable GC systems for on-site biodiesel quality assessment. Continued innovation aims to further improve throughput, sensitivity, and sustainability of biodiesel analytics.
Conclusion
Selecting tailored GC columns, retention gaps, and accessories significantly enhances biodiesel quality testing by improving resolution, thermal stability, and laboratory efficiency. The combination of Rtx®-Biodiesel TG, MXT®-Biodiesel TG, Stabilwax®, and Rtx®-1 columns, along with supporting hardware, provides a complete solution for rigorous compliance with ASTM and European biodiesel standards.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Biodiesel Solutions - Innovative Products for Simple, Reliable Biodiesel Analysis
2020|Restek|Brochures and specifications
Restek Refined Biodiesel Solutions Innovative Products for Simple, Reliable Biodiesel Analysis • MXT-Biodiesel TG, Rtx-Biodiesel TG, and FAMEWAX columns— engineered specifically for high-performance biodiesel analysis. • GC accessories to simplify your lab work and increase productivity. • Analytical reference materials—high-quality…
Key words
ambient, ambientbiodiesel, biodieselrestek, restekleak, leakmxt, mxtfused, fusedglycerin, glycerindescription, descriptionsilica, silicagap, gapship, shipdetector, detectorcharging, chargingyes, yescool
Accurate Analysis of Glycerol and Glycerides in Biodiesel Oil Using EN 14105 (2011) and Robust Metal MXT Columns
2018|Agilent Technologies|Applications
Accurate Analysis of Glycerol and Glycerides in Biodiesel Oil Using EN 14105 (2011) and Robust Metal MXT Columns • Total solution for analysis of free glycerol, mono-, di-, and triglycerides in biodiesel. • Rugged metal MXT column ensures longevity and…
Key words
cooch, coochbiodiesel, biodieselmstfa, mstfatriglycerides, triglyceridesglycerol, glycerolmxt, mxtmonoglycerides, monoglyceridesdiglycerides, diglyceridesglycerides, glyceridesheptane, heptanederivatized, derivatizedmethyl, methylzone, zonetrimethylsilytrifluoroacetamide, trimethylsilytrifluoroacetamideoven
Application Book Volume 4 - Biodiesel Quality Control
|Shimadzu|Guides
SEG-A-081 Quality Control According to DIN EN 14103, 14105, 14110 Application Book Volume 4 Biodiesel Quality Control Application Book Volume 4 Biodiesel Quality Control Contents I. Determination of methanol in biodiesel 5 II. Fatty acid methyl esters (FAME) Determination of…
Key words
biodiesel, biodieselmethyl, methylglycerin, glycerintriglyceride, triglycerideester, esterdiglyceride, diglyceridemonoolein, monooleinacid, acidtriglycerides, triglyceridesfatty, fattymonoglycerides, monoglyceridesdiglycerides, diglyceridesgcsolution, gcsolutionstandard, standarddin
Rxi® GC Columns - Leverage the outstanding inertness, low bleed, and high reproducibility of Rxi® 3-in-1 technology to gain
2015|Restek|Brochures and specifications
Leverage the outstanding inertness, low bleed, and high reproducibility of Rxi® 3-in-1 technology to gain: • Accurate Data • The Right Results Fast • Maximized Instrument Uptime Pure Chromatography www.restek.com/rxi Rxi®-1ms............................................................................... 2 Rxi®-5ms............................................................................... 3 Rxi®-XLB................................................................................ 3 Rxi®-5Sil MS......................................................................... 4 Rxi®-35Sil…
Key words
price, pricerxi, rxinonpolar, nonpolarcrossbond, crossbondstabilwax, stabilwaxxlb, xlbmidpolarity, midpolarityrestek, restekgcxgc, gcxgcphases, phasesphase, phasesimilar, similarpolysiloxane, polysiloxanecolumns, columnsguard