Increase Sample Throughput with New 15-Minute, Low-Level PAH GC-MS Analysis
Applications | 2018 | RestekInstrumentation
Rapid and sensitive detection of polycyclic aromatic hydrocarbons (PAHs) is critical due to their widespread occurrence and carcinogenic potential. Environmental monitoring, food safety, and industrial quality control demand methods that can reliably quantify trace-level PAHs while maximizing laboratory throughput. The integration of scaled-down GC methods with enhanced oven ramp capabilities addresses both speed and sensitivity requirements without extensive capital investment.
This work demonstrates how to convert a conventional semivolatile analysis (e.g., EPA Method 8270D) into a fast, low-level PAH assay using existing GC-MS equipment. Key aims include:
The optimized, scaled-down method achieved baseline separation of 16 priority PAHs plus methyl-naphthalenes in just 15 minutes. Even at 0.05 ng on-column, peaks exhibited sharp shapes and reproducible response factors. The use of a 9 mm extractor lens minimized tailing at trace levels, while SIM mode provided strong molecular ion signals with minimal interference. Calibration linearity met method criteria after adopting appropriate fit models for low-level points.
Advances in column technology, further miniaturization of GC ovens, and AI-driven method translation promise even faster and more sensitive PAH analyses. Integration with high-resolution MS and automated sample introduction systems will expand applicability to complex matrices. Ongoing development of robust surface coatings and source components will further reduce memory effects and tailing at ultra-trace levels.
The combination of a scaled-down Rxi-5Sil MS column, GC Accelerator kit, and SIM-based detection delivers high-throughput, low-level PAH analysis on standard GC-MS platforms. This approach meets stringent sensitivity requirements in 15 minutes without compromising separation quality, offering a cost-effective upgrade path for laboratories focused on environmental, food, and industrial applications.
GC/MSD, GC/SQ, GC columns, Consumables
IndustriesManufacturerAgilent Technologies, Restek
Summary
Significance of the Topic
Rapid and sensitive detection of polycyclic aromatic hydrocarbons (PAHs) is critical due to their widespread occurrence and carcinogenic potential. Environmental monitoring, food safety, and industrial quality control demand methods that can reliably quantify trace-level PAHs while maximizing laboratory throughput. The integration of scaled-down GC methods with enhanced oven ramp capabilities addresses both speed and sensitivity requirements without extensive capital investment.
Objectives and Study Overview
This work demonstrates how to convert a conventional semivolatile analysis (e.g., EPA Method 8270D) into a fast, low-level PAH assay using existing GC-MS equipment. Key aims include:
- Adapting a traditional 30 m column method to a 20 m, narrow-bore column format.
- Leveraging selected ion monitoring (SIM) for increased sensitivity to detect PAHs at 0.05 ng on-column.
- Employing a GC Accelerator kit to boost oven ramp rates and reduce cycle time to 15 minutes.
Methodology and Instrumentation
- Column: Rxi-5Sil MS, 20 m × 0.15 mm ID, 0.15 µm film.
- Instrument: Agilent 7890B GC coupled to 5977A MSD, operated in SIM mode.
- Oven program: 60 °C hold 0.7 min; 39.8 °C/min to 285 °C; 4.3 °C/min to 305 °C; 28.5 °C/min to 320 °C, 3.5 min hold.
- GC Accelerator kit: boosts ramp rates on 120 V ovens without hardware changes.
- Source conditions: Extractor source at 330 °C, 9 mm lens; quadrupole at 180 °C.
- Standards: EPA 8310 PAH mix, surrogate and internal standards for quantitation.
Main Results and Discussion
The optimized, scaled-down method achieved baseline separation of 16 priority PAHs plus methyl-naphthalenes in just 15 minutes. Even at 0.05 ng on-column, peaks exhibited sharp shapes and reproducible response factors. The use of a 9 mm extractor lens minimized tailing at trace levels, while SIM mode provided strong molecular ion signals with minimal interference. Calibration linearity met method criteria after adopting appropriate fit models for low-level points.
Benefits and Practical Applications
- Substantial reduction in analysis time enhances sample throughput and laboratory efficiency.
- Low-level detection capability supports regulatory compliance in environmental and food matrices.
- No major hardware investments required—existing GC-MS systems can be upgraded via the GC Accelerator kit.
- Maintains familiar method workflows and data processing for routine semivolatile analyses.
Future Trends and Opportunities
Advances in column technology, further miniaturization of GC ovens, and AI-driven method translation promise even faster and more sensitive PAH analyses. Integration with high-resolution MS and automated sample introduction systems will expand applicability to complex matrices. Ongoing development of robust surface coatings and source components will further reduce memory effects and tailing at ultra-trace levels.
Conclusion
The combination of a scaled-down Rxi-5Sil MS column, GC Accelerator kit, and SIM-based detection delivers high-throughput, low-level PAH analysis on standard GC-MS platforms. This approach meets stringent sensitivity requirements in 15 minutes without compromising separation quality, offering a cost-effective upgrade path for laboratories focused on environmental, food, and industrial applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Faster Semivolatiles Analysis with a Scaled-Down Method and GC Accelerator Kit
2018|Agilent Technologies|Technical notes
Faster Semivolatiles Analysis with a ScaledDown Method and GC Accelerator Kit Analysis times for semivolatile compounds can limit sample throughput and decrease overall lab productivity. You can significantly speed up methods on your existing GC-MS by using a properly scaled-down…
Key words
accelerator, acceleratorbenzo, benzophthalate, phthalatescaled, scaledfluoranthene, fluoranthenedown, downkit, kitpyrene, pyreneoven, ovenpeaks, peaksanthracene, anthracenecolumn, columnbutyl, butylmethod, methodezgc
Guide to Preparing and Analyzing Semivolatile Organic Compounds
2002|Restek|Guides
Guide to Preparing and Analyzing Semivolatile Organic Compounds Inside: Introduction ..................... pg. 2 Extraction Liquid samples ................. pg. 2 Soil samples ..................... pg. 4 Cleanup ............................ pg. 5 Gel Permeation Chromatography .............. pg. 5 Analysis Calibration standards ...... pg. 6…
Key words
pack, packbenzo, benzophthalate, phthalatefluoranthene, fluorantheneeach, eachkit, kitpyrene, pyrenedata, datagcs, gcsanthracene, anthracenebenzyl, benzylpentachlorophenol, pentachlorophenolendrin, endrinmixtures, mixturespropylamine
Analyze More Semivolatile Samples per Shift Using Split Injection and an Rxi-5Sil MS Column
2018|Agilent Technologies|Applications
Featured Application: Extractable Semivolatile Organic Compounds on Rxi-5Sil MS Analyze More Semivolatile Samples per Shift Using Split Injection and an Rxi-5Sil MS Column • Faster oven cycle increases sample throughput. • Split injection reduces maintenance frequency. • Reliably meets or…
Key words
phthalate, phthalatebenzo, benzoleak, leakadaptor, adaptorfluoranthene, fluoranthenecharger, chargerbenzoic, benzoicrestek, restekanthracene, anthracenepyrene, pyrenedetector, detectoruniversal, universalbutyl, butyldon't, don'tsided
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
2017|Agilent Technologies|Applications
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven 18,19 11 1,2 Ion 276.10 Ion 278.10 Ion 138.00 15,16 17 5 12 13 67 8 3 20 14 Benzo Fluoranthenes Valley=…
Key words
benzo, benzofluoranthene, fluorantheneanthracene, anthracenepyrene, pyrenefluoranthenes, fluoranthenesdftpp, dftppmin, minghi, ghibenz, benzperylene, peryleneextractor, extractoracenaphthylene, acenaphthyleneacenaphthene, acenaphthenefluorene, fluorenephenanthrene