Guide to Preparing and Analyzing Semivolatile Organic Compounds
Guides | 2002 | RestekInstrumentation
Semivolatile organic compounds (SVOCs) such as phenols, polycyclic aromatic hydrocarbons (PAHs), and pesticides are widespread environmental contaminants. Their toxicity and persistence make accurate monitoring essential for regulatory compliance and environmental protection under US EPA methods.
This guide presents best practices for preparing, cleaning up, and analyzing SVOCs using gas chromatography/mass spectrometry (GC/MS). It addresses common challenges, offers troubleshooting tips, and aligns procedures with EPA Methods 8270, 525, 625, 610, and 8100.
Emerging technologies such as enhanced automated extraction (e.g., next-generation ASE, improved SFE), novel ultralow-bleed stationary phases, and integrated digital methods optimization will further streamline SVOC analysis.
Effective GC/MS analysis of semivolatile organics hinges on controlled sample preparation, targeted cleanup, precise injection port configuration, and judicious column selection. Adhering to best practices minimizes analytical errors, extends instrument life, and ensures regulatory compliance.
Sample Preparation
IndustriesEnvironmental
ManufacturerRestek
Summary
Importance of Semivolatile Organic Compound Analysis
Semivolatile organic compounds (SVOCs) such as phenols, polycyclic aromatic hydrocarbons (PAHs), and pesticides are widespread environmental contaminants. Their toxicity and persistence make accurate monitoring essential for regulatory compliance and environmental protection under US EPA methods.
Objectives and Overview
This guide presents best practices for preparing, cleaning up, and analyzing SVOCs using gas chromatography/mass spectrometry (GC/MS). It addresses common challenges, offers troubleshooting tips, and aligns procedures with EPA Methods 8270, 525, 625, 610, and 8100.
Methodology and Instrumentation
- Extraction of Liquid Samples: separatory funnel (EPA 3510), automated liquid–liquid extraction (EPA 3520), and solid-phase extraction (EPA 3535).
- Extraction of Soil and Biota: Soxhlet and ultrasonic methods; pressurized fluid extraction (ASE, EPA 3545A); microwave extraction (EPA 3546); limited use of supercritical fluid extraction (SFE, Methods 3560–3562).
- Cleanup: gel permeation chromatography (GPC, EPA 3640) to remove lipids, sulfur, and high-boiling hydrocarbons.
- Drying and Concentration: use of granular sodium sulfate to eliminate water before solvent reduction.
- Injection Optimization: splitless and split modes; fused-silica wool and gooseneck liners; drilled Uniliner® to reduce high-molecular-weight discrimination; splitless hold-time optimization (~60 s); pressure pulsing and routine liner/septum replacement.
- Column Selection: low-bleed, inert phases such as Rtx®-5Sil MS and Rtx®-5MS; Integra-Guard™ columns; high-quality ferrules and connectors ensure leak-free operation.
- Instrumentation Platforms: Agilent 5890/6890, Varian 3400/3600/3800, PerkinElmer Autosystem, Shimadzu 14A/17A GCs paired with MS detectors (e.g., Agilent 5971/5972/5973, Varian Saturn 2000).
Main Results and Discussion
- Extraction Efficiency: pH adjustment and solvent choice critically affect recoveries; automated extractors yield unattended operation but may require re-extraction for low yields or emulsions.
- GPC Cleanup Performance: effectively separates SVOCs from interfering lipids and sulfur; daily retention-time checks and periodic column flushing maintain accuracy.
- Injection Port Parameters: optimized splitless hold-time maximizes late-eluting SVOC response while minimizing solvent tailing; drilled Uniliner® liners enhance recovery of high-MW compounds.
- Column Capacity and Resolution: selection of appropriate ID and film thickness (e.g., 0.25 mm×0.5 µm or 0.28 mm×0.5 µm for splitless injection) prevents overload at calibration levels up to 160 ng.
- Low-Bleed Columns: Rtx®-5Sil MS columns demonstrate minimal bleed at trace levels, improving MS sensitivity and avoiding detector saturation and calibration roll-off.
Practical Benefits and Applications
- Regulatory Compliance: robust protocols ensure reliable detection of SVOCs in environmental and industrial samples.
- Instrument Longevity: thorough cleanup and optimized injection routines reduce contamination of the inlet and column.
- Quality Assurance: internal standard calibration and routine maintenance support consistent quantitation and data integrity.
Future Trends and Potential Developments
Emerging technologies such as enhanced automated extraction (e.g., next-generation ASE, improved SFE), novel ultralow-bleed stationary phases, and integrated digital methods optimization will further streamline SVOC analysis.
Conclusion
Effective GC/MS analysis of semivolatile organics hinges on controlled sample preparation, targeted cleanup, precise injection port configuration, and judicious column selection. Adhering to best practices minimizes analytical errors, extends instrument life, and ensures regulatory compliance.
References
- US EPA Methods 8270D, 525.2, 625, 610, 8100.
- US EPA Methods 3510, 3520, 3535, 3545A, 3546, 3560–3562, and 3640.
- Restek Application Note “SPE Extraction for US EPA Method 525.1.”
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Faster Semivolatiles Analysis with a Scaled-Down Method and GC Accelerator Kit
2018|Agilent Technologies|Technical notes
Faster Semivolatiles Analysis with a ScaledDown Method and GC Accelerator Kit Analysis times for semivolatile compounds can limit sample throughput and decrease overall lab productivity. You can significantly speed up methods on your existing GC-MS by using a properly scaled-down…
Key words
accelerator, acceleratorbenzo, benzophthalate, phthalatescaled, scaledfluoranthene, fluoranthenedown, downkit, kitpyrene, pyreneoven, ovenpeaks, peaksanthracene, anthracenecolumn, columnbutyl, butylmethod, methodezgc
Analyze More Semivolatile Samples per Shift Using Split Injection and an Rxi-5Sil MS Column
2018|Agilent Technologies|Applications
Featured Application: Extractable Semivolatile Organic Compounds on Rxi-5Sil MS Analyze More Semivolatile Samples per Shift Using Split Injection and an Rxi-5Sil MS Column • Faster oven cycle increases sample throughput. • Split injection reduces maintenance frequency. • Reliably meets or…
Key words
phthalate, phthalatebenzo, benzoleak, leakadaptor, adaptorfluoranthene, fluoranthenecharger, chargerbenzoic, benzoicrestek, restekanthracene, anthracenepyrene, pyrenedetector, detectoruniversal, universalbutyl, butyldon't, don'tsided
New! Rxi®-5Sil MS Capillary GC Columns
2008|Restek|Brochures and specifications
New! Rxi®-5Sil MS Capillary GC Columns Fast, Accurate Semivolatiles Analysis • Ultra-low bleed columns save you time and money with faster baseline stabilization. • Outstanding inertness for low quantification limits of active compounds. • Guaranteed column-to-column reproducibility. Chromatography Products www.restek.com…
Key words
phthalate, phthalatebenzo, benzoeic, eicexcellent, excellentpyridine, pyridinefluoranthene, fluoranthenebenzyl, benzylrestek, restekpahs, pahsanthracene, anthracenepyrene, pyreneregistered, registeredscan, scantransfer, transferbutyl
A Guide to Preparing and Analyzing Chlorinated Pesticides
1999|Restek|Guides
Technical Guide A Guide to Preparing and Analyzing Chlorinated Pesticides Inside: Extraction Methods for Liquid, Solid, and Biota Samples Sample Cleanup Methods Analysis of Chlorinated Pesticides Summary 2 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○…
Key words
pack, packbhc, bhcendrin, endrinendosulfan, endosulfanchlordane, chlordanehch, hchheptachlor, heptachlorclpesticides, clpesticidesdata, dataeach, eachrtx, rtxester, esterextraction, extractionpress, presstight