Reference Naphtha Standard

Applications |  | QuadrexInstrumentation
GC, GC columns, Consumables
Industries
Energy & Chemicals
Manufacturer
Quadrex

Summary

Importance of Naphtha Analysis in Petrochemical Industry


The separation and analysis of naphtha fractions are essential for quality control and product characterization in the petrochemical sector. Detailed hydrocarbon profiling enables process optimization, compliance with regulatory standards and improved fuel performance.

Study Objectives and Overview


This application focuses on the gas chromatographic separation of a representative naphtha sample using a dimethylpolysiloxane capillary column. The aim is to demonstrate the resolution of up to eighty nine hydrocarbon components, including linear and branched alkanes, cycloalkanes and aromatics.

Methodology and Instrumentation


  • Column 007-1: 50 m length, 0.25 mm internal diameter, 0.5 µm film thickness
  • Stationary phase: dimethylpolysiloxane
  • Temperature program: initial 35 °C with a 30 min hold, then ramp at 2 °C/min to 200 °C with final hold
  • Injector temperature: 200 °C
  • Detector: flame ionization detector at 250 °C
  • Carrier gas: helium at a linear velocity of 19.8 cm/s

Main Results and Discussion


The method achieved baseline separation of eighty nine distinct hydrocarbon species, spanning from C3 aliphatics to C12 paraffins and naphthenes. Clear resolution was obtained for structural and stereoisomers such as dimethylbutanes, trimethylpentanes, ethylcyclopentanes and multiple methylhexane configurations. Aromatic compounds including benzene, toluene and the xylene isomers eluted later in the run, confirming the column’s ability to separate both saturated and unsaturated species effectively.

Benefits and Practical Applications


This chromatographic approach offers reliable identification and quantification of naphtha constituents for refinery quality assurance, environmental monitoring and research laboratories. Its high separation efficiency supports detection of trace isomers and potential contaminants, aiding in compliance and process control.

Future Trends and Applications


Emerging developments may include coupling to mass spectrometry for enhanced compound confirmation, adopting rapid temperature programming for shorter analysis times, and exploring alternative inert carrier gases. The integration of automated sampling and miniaturized GC systems promises higher throughput and field deployability.

Conclusion


The described GC method using a dimethylpolysiloxane capillary column provides comprehensive separation of complex naphtha mixtures. It meets stringent analytical demands in the petrochemical industry and sets the stage for further innovations in speed, sensitivity and automation.

Reference


GC Capillary Column Applications Petrochemical Application Note by Quadrex Corporation

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Detailed Hydrocarbon Analysis of Naphtha Nexis GC-2030PONA2
SGC-ADS-0173 System Gas Chromatograph 173 Detailed Hydrocarbon Analysis of Naphtha Nexis GC-2030PONA2 A representative sample of the Naphtha in introduced into a gas chromatogram equipped with a methyl silicone bonded phase fused silica capillary column. Helium carrier gas transports the…
Key words
trimethylcyclopentane, trimethylcyclopentaneethylmethylcyclopentane, ethylmethylcyclopentanedimethylcyclohexane, dimethylcyclohexanedimethylcyclopentane, dimethylcyclopentanepropylcyclopentane, propylcyclopentaneethylcyclohexane, ethylcyclohexanexylene, xyleneethylcyclopentane, ethylcyclopentaneneopentane, neopentanecyclopentane, cyclopentanemethylcyclopentane, methylcyclopentaneisopentane, isopentanenaphtha, naphthaisobutane, isobutaneoctane
Analysis of gasoline range hydrocarbons
Analysis of gasoline range hydrocarbons
2017|Trajan Scientific|Applications
APPLICATION NOTE Analysis of gasoline range hydrocarbons BP1 Column part number 054950 Phase BP1 Rate 3 10°C/min to 190°C Column 50 m x 0.15 mm x 0.5 μm Final temperature 190°C Initial temperature 30°C, 5 min Detector FID Rate 1…
Key words
gasoline, gasolinehydrocarbons, hydrocarbonscomponents, componentsnote, notetemperature, temperaturerange, rangefid, fidapplication, applicationfinal, finalcolumn, columninitial, initialsplit, splitpart, partcarrier, carrieranalysis
Octans and Lower Boiling Hydrocarbons in Olefin-Free Gasolines
SGC-ADS-0180 System Gas Chromatograph Octans and Lower Boiling Hydrocarbons in Olefin-Free Gasolines 180 Nexis GC-2030LBH3 This system is for determining the composition of C8 or lower boiling paraffins and naphthenes in olefin-free gasolines. Detailed identification is enabled by comparing chromatograms…
Key words
xylene, xyleneoctans, octansisopropylcyclopentane, isopropylcyclopentanepropylcyclopentane, propylcyclopentaneethylcyclohexane, ethylcyclohexaneethylcyclopentane, ethylcyclopentanemin, minfid, fidgasolines, gasolinescyclopentane, cyclopentanemethylcyclopentane, methylcyclopentaneone, oneisopentane, isopentanespl, splolefin
Reference Reformate Standard
Reference Reformate Standard
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Petrochemical Reference Reformate Standard COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: 1. propane 2. isobutane 3. n-butane 4. isopentane 5. n-pentane 6. 2,2-dimethylbutane 7. cyclopentane 8. 2,3-dimethylbutane 9. 2-methylpentane 10. 3-methylpentane 11. n-hexane 12. 2,2-dimethylpentane…
Key words
reformate, reformatecyclopentane, cyclopentanedimethylpolysiloxane, dimethylpolysiloxanepetrochemical, petrochemicalreference, referencestandard
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike