Fame Mix
Applications | | QuadrexInstrumentation
Fatty acid methyl ester (FAME) profiling is a cornerstone technique in food science, lipid research, quality control, and environmental analysis. Accurate separation and quantification of individual FAMEs enable researchers to assess nutritional value, trace biosynthetic pathways, and detect adulteration in oils and fats. Robust chromatographic methods ensure reliable data across diverse applications.
This application note demonstrates an optimized gas chromatography–flame ionization detection (GC–FID) method for the separation of 14 common FAMEs. The goal is to showcase column performance, separation efficiency, and operational parameters using a bonded cyanopropyl polysiloxane capillary column under a defined temperature program.
The method employs the following configuration and conditions:
The chromatographic conditions achieve baseline resolution of 14 FAME peaks, including cis/trans isomers of C16 and C18. The bonded cyanopropyl phase provides selectivity for unsaturated and trans configurations, minimizing coelution. Peak shapes are sharp, with retention times correlating consistently to carbon number and degree of unsaturation. Method repeatability shows retention time variation below 0.2 % relative standard deviation.
Users can leverage this protocol for:
Emerging directions include coupling this column chemistry with mass spectrometric detection to enhance sensitivity and selectivity for minor FAME components. Ultra-fast temperature programming and narrower bore columns may reduce analysis time further. Additionally, automated sample prep and derivatization workflows are expected to streamline FAME profiling in high-throughput settings.
The presented GC–FID method using a bonded cyanopropyl polysiloxane capillary column delivers reliable separation of key FAMEs with excellent reproducibility. Its straightforward temperature program and standardized conditions support diverse applications in research and quality assurance, offering a balance of resolution, speed, and operational simplicity.
GC, GC columns, Consumables
IndustriesFood & Agriculture, Energy & Chemicals
ManufacturerQuadrex
Summary
Importance of the Topic
Fatty acid methyl ester (FAME) profiling is a cornerstone technique in food science, lipid research, quality control, and environmental analysis. Accurate separation and quantification of individual FAMEs enable researchers to assess nutritional value, trace biosynthetic pathways, and detect adulteration in oils and fats. Robust chromatographic methods ensure reliable data across diverse applications.
Objectives and Study Overview
This application note demonstrates an optimized gas chromatography–flame ionization detection (GC–FID) method for the separation of 14 common FAMEs. The goal is to showcase column performance, separation efficiency, and operational parameters using a bonded cyanopropyl polysiloxane capillary column under a defined temperature program.
Methodology and Instrumentation
The method employs the following configuration and conditions:
- Column: Bonded Cyanopropyl Polysiloxane, 25 m × 0.25 mm I.D., 0.25 μm film (Cat. No. 007-23-25-0.25F)
- Temperature Program: 100 °C initial, ramp at 8 °C/min to 240 °C
- Injector Temperature: 230 °C
- Detector (FID) Temperature: 300 °C
- Carrier Gas: Helium at 28 cm/s linear velocity
Key Results and Discussion
The chromatographic conditions achieve baseline resolution of 14 FAME peaks, including cis/trans isomers of C16 and C18. The bonded cyanopropyl phase provides selectivity for unsaturated and trans configurations, minimizing coelution. Peak shapes are sharp, with retention times correlating consistently to carbon number and degree of unsaturation. Method repeatability shows retention time variation below 0.2 % relative standard deviation.
Benefits and Practical Applications
Users can leverage this protocol for:
- Quality control of edible oils and biodiesel feedstocks
- Nutritional labeling by quantifying saturated versus unsaturated fatty acids
- Monitoring industrial lipid processing and refining
- Environmental studies of fatty acid biomarkers
Future Trends and Potential Applications
Emerging directions include coupling this column chemistry with mass spectrometric detection to enhance sensitivity and selectivity for minor FAME components. Ultra-fast temperature programming and narrower bore columns may reduce analysis time further. Additionally, automated sample prep and derivatization workflows are expected to streamline FAME profiling in high-throughput settings.
Conclusion
The presented GC–FID method using a bonded cyanopropyl polysiloxane capillary column delivers reliable separation of key FAMEs with excellent reproducibility. Its straightforward temperature program and standardized conditions support diverse applications in research and quality assurance, offering a balance of resolution, speed, and operational simplicity.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
C1 to C10 Hydrocarbons
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Petrochemical C1 to C10 Hydrocarbons COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier: 007-1, Dimethylpolysiloxane PHAT Phase™ 20M. x 0.18mm I.D. x 6.0μm film 007-1-20HS-6.0F 35° (3 min. hold) (2°/min.) 48° - (6°/min.) - 210°C, hold. 200°C…
Key words
petrochemical, petrochemicalhydrocarbons
Reference Naphtha Standard
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Petrochemical Reference Naphtha Standard COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: 1. propane 2. isobutane 3. n-butane 4. isopentane 5. n-pentane 6. 2,2-dimethylbutane 7. cyclopentane 8. 2,3-dimethylbutane 9. 2-methylpentane 10. 3-methylpentane 11. n-hexane 12. 2,2-dimethylpentane…
Key words
propylcyclopentane, propylcyclopentanestereoisomers, stereoisomersdimethylpolysiloxane, dimethylpolysiloxanenaphtha, naphthapetrochemical, petrochemicalreference, referencestandard
EPA Method 601 Standards
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Environmental EPA Method 601 Standards COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: 007-624, Cyanopropyl Phenyl Methylpolysiloxane 30M. x 0.53mm I.D. x 3.0μm film 007-624-30V-3.0F 35° (2 min. hold) (7°/min.) - 125°C 220°C 300°C, ECD 6…
Key words
methylpolysiloxane, methylpolysiloxanecyanopropyl, cyanopropylphenyl, phenylepa, epaenvironmental, environmentalstandards, standardsmethod
PUFA 2 Animal Source Bnded Cyanopropyl Polysiloxane
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Fames PUFA 2 Animal Source COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: 007-23, Bonded Cyanopropyl Polysiloxane 50M. x 0.25mm I.D. x 0.25μm film 007-23-50-0.25F 60° (5°/min.) - 260°C 230°C 300°C, FID 28 cm/sec., Helium 1.…
Key words
cyanopropyl, cyanopropylpolysiloxane, polysiloxanefames, famesanimal, animalsource