Alcohols
Applications | | QuadrexInstrumentation
Monitoring volatile alcohols in environmental samples is essential for assessing air and water quality, evaluating industrial emissions and ensuring compliance with regulatory limits. Gas chromatography coupled with a flame ionization detector (GC–FID) offers high sensitivity and reproducible separation of small alcohols, supporting routine analysis in environmental laboratories.
This application note demonstrates the use of a BTR-CW Carbowax capillary column for the separation and quantification of twelve common alcohols under controlled temperature programming. The goal is to achieve baseline resolution of isomeric and homologous alcohols in a single run, highlighting the method’s suitability for environmental analyses.
Temperature Program:
Column Details:
GC Conditions:
The twelve alcohols—ranging from methanol to 1-pentanol, including branched isomers—were fully resolved with sharp, symmetrical peaks. Early eluters (methanol, ethanol, 2-propanol) showed consistent retention times, while higher homologs and branched compounds (e.g., 2-methyl-2-butanol) were well separated due to the polar Carbowax phase. The optimized temperature ramp balanced analysis time and resolution, completing separation within a moderate runtime.
Advances in column technology and faster temperature programming could further reduce analysis times. Coupling such polar columns with mass spectrometry (GC–MS) will enhance identification of trace alcohols in complex matrices. Automated sample preparation and integration into field-deployable systems are emerging trends that will expand real-time monitoring capabilities.
The BTR-CW Carbowax capillary column coupled with GC–FID provides a reliable and efficient method for separating a broad range of volatile alcohols. Its robustness, resolution of isomers and adaptability to environmental sample analysis make it a valuable tool for regulatory compliance and research applications.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerQuadrex
Summary
Analysis of Volatile Alcohols by GC Capillary Column for Environmental Monitoring
Importance of the Topic
Monitoring volatile alcohols in environmental samples is essential for assessing air and water quality, evaluating industrial emissions and ensuring compliance with regulatory limits. Gas chromatography coupled with a flame ionization detector (GC–FID) offers high sensitivity and reproducible separation of small alcohols, supporting routine analysis in environmental laboratories.
Aim and Overview of the Study
This application note demonstrates the use of a BTR-CW Carbowax capillary column for the separation and quantification of twelve common alcohols under controlled temperature programming. The goal is to achieve baseline resolution of isomeric and homologous alcohols in a single run, highlighting the method’s suitability for environmental analyses.
Methodology and Instrumentation
Temperature Program:
- Initial: 50 °C, ramp at 5 °C/min to 100 °C
Column Details:
- Stationary Phase: Carbowax BTR oxygen-resistant
- Length × I.D. × Film: 30 m × 0.53 mm × 1.0 μm
- Catalog Number: BTR-CW-30V-1.0F
GC Conditions:
- Injector Temperature: 220 °C
- Detector: FID at 250 °C
- Carrier Gas: Helium at 21.7 cm/s linear velocity
Main Results and Discussion
The twelve alcohols—ranging from methanol to 1-pentanol, including branched isomers—were fully resolved with sharp, symmetrical peaks. Early eluters (methanol, ethanol, 2-propanol) showed consistent retention times, while higher homologs and branched compounds (e.g., 2-methyl-2-butanol) were well separated due to the polar Carbowax phase. The optimized temperature ramp balanced analysis time and resolution, completing separation within a moderate runtime.
Benefits and Practical Applications
- High resolution of isomeric alcohols in a single chromatogram
- Reproducible retention times and peak shapes suited for quantitative analysis
- Robust performance for routine environmental monitoring of water and air samples
- Compatibility with standard GC–FID setups in QA/QC laboratories
Future Trends and Potential Applications
Advances in column technology and faster temperature programming could further reduce analysis times. Coupling such polar columns with mass spectrometry (GC–MS) will enhance identification of trace alcohols in complex matrices. Automated sample preparation and integration into field-deployable systems are emerging trends that will expand real-time monitoring capabilities.
Conclusion
The BTR-CW Carbowax capillary column coupled with GC–FID provides a reliable and efficient method for separating a broad range of volatile alcohols. Its robustness, resolution of isomers and adaptability to environmental sample analysis make it a valuable tool for regulatory compliance and research applications.
Použitá instrumentace
- GC Column: BTR-CW-30V-1.0F (30 m × 0.53 mm I.D. × 1.0 μm Carbowax BTR)
- Injector: 220 °C split/splitless
- Detector: FID at 250 °C
- Carrier Gas: Helium, 21.7 cm/s linear velocity
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Celery Seed Oil
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Flavors/Fragrances Celery Seed Oil COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: BTR-CW, Carbowax/ BTR -Oxygen Resistant 30M. x 0.25mm I.D. x 0.25μm film BTR-CW-30-0.25F 60° (5°/min.) - 240°C 225°C 250°C, FID 27 cm/sec., Helium PO…
Key words
btr, btrcelery, celeryfragrances, fragrancesseed, seedflavors, flavorsresistant, resistantoxygen, oxygenoil
PUFA 2 Animal Source R-CW
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Fames PUFA 2 Animal Source COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: BTR-CW, Carbowax/BTR Oxygen Resistant 30M. x 0.25mm I.D. x 0.25μm film BTR-CW-30-0.25F 60° (5 min. hold) (10°/min.) -150° (4°/min) - 240°C 230°C 250°C,…
Key words
btr, btrcarbowax, carbowaxfames, famesresistant, resistantanimal, animaloxygen, oxygensource
Aldehydes
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Flavors/Fragrances Aldehydes COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: BTR-CW, Carbowax/ BTR -Oxygen resistant 30M. x 0.25mm I.D. x 0.25μm film BTR-CW-30-0.25F 75° (5°/min) - 220°C 230°C 300°C , FID 33 cm/sec., Helium 1. ethyl…
Key words
btr, btrfragrances, fragrancesaldehydes, aldehydesflavors, flavorsaldehyde, aldehyderesistant, resistantoxygen
Residual Solvents in Drugs USP Method 467
|Quadrex|Applications
GC CAPILLARY COLUMN APPLICATIONS: Industrial Solvents Residual Solvents in Drugs USP Method 467 COLUMN: Cat. No.: Temperature: Injector: Detector: Carrier Gas: 007-1, Dimethylpolysiloxane 30M. x 0.32mm I.D. x 10.0μm film 007-1-30W-10.0F 50° (4 min. hold) (5°/min.) - 200°C 220°C 290°C,…
Key words
dimethylpolysiloxane, dimethylpolysiloxanesolvents, solventsindustrial, industrialusp, uspresidual, residualdrugs, drugsmethod