Response Comparison of Agilent SPME Arrows and Agilent SPME Fibers with DVB/Carbon WR/PDMS Phase for Free Volatile Phenols
Applications | 2021 | Agilent TechnologiesInstrumentation
Recent advances in SPME Arrow design extend sorptive capacity and mechanical robustness, enabling more sensitive and reliable trace-level analysis in food, wine and environmental testing.
The study aims to quantify improvements in extraction efficiency, signal response and practical advantages of the Arrow format over the traditional fiber.
Extractions used Agilent DVB/carbon WR/PDMS coatings in both 100 µm fiber and 1.10 mm Arrow formats under the following conditions:
GC/MS parameters:
Additional phenolic compounds commonly associated with smoke-impacted wine, such as cresols, phenols and ethylphenol isomers, also exhibited enhanced responses with the Arrow format, confirming its superior sorption phase volume and extraction efficiency.
Integration with two-dimensional GC and high-resolution MS promises further gains in selectivity and sensitivity for trace-level analysis.
Its robust design and larger sorptive volume make it a valuable tool for modern analytical laboratories seeking improved performance and throughput.
GC/MSD, SPME, GC/SQ, Consumables
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Summary
Significance of the Topic
Solid phase microextraction (SPME) has become a cornerstone technique in analytical chemistry for sampling and concentrating volatile compounds with minimal solvent use and seamless integration into gas chromatography–mass spectrometry (GC/MS) workflows.Recent advances in SPME Arrow design extend sorptive capacity and mechanical robustness, enabling more sensitive and reliable trace-level analysis in food, wine and environmental testing.
Objectives and Study Overview
This application brief evaluates the performance differences between a conventional Agilent DVB/carbon WR/PDMS SPME fiber and the larger-volume Agilent SPME Arrow (1.10 mm) for headspace extraction of free volatile phenols, notably guaiacol and 4-methylguaiacol, in smoke-impacted wine model solutions.The study aims to quantify improvements in extraction efficiency, signal response and practical advantages of the Arrow format over the traditional fiber.
Methodology and Instrumentation
Headspace SPME extractions were performed in 20 mL vials containing 10 mL sample with 4 g NaCl, spiked at 50 ppb of target analytes.Extractions used Agilent DVB/carbon WR/PDMS coatings in both 100 µm fiber and 1.10 mm Arrow formats under the following conditions:
- Predesorption: 3 min at 250 °C
- Incubation: 5 min at 40 °C with 1 000 rpm stirring
- Extraction: 10 min headspace exposure
- Desorption: 3 min in splitless inlet at 250 °C
GC/MS parameters:
- Agilent 8890 GC with J&W DB-HeavyWAX column (30 m × 0.32 mm, 0.25 µm)
- Oven program: 120 °C (1 min), 10 °C/min to 250 °C, then 60 °C/min to 280 °C
- Agilent 5977B MSD in SIM mode, transfer line 280 °C, source 280 °C, quadrupole 150 °C
Instrumentation
- Agilent 8890 Gas Chromatograph
- Agilent 5977B Mass Selective Detector
- Agilent PAL3 Autosampler with Robotic Tool Change
- DVB/carbon WR/PDMS SPME fiber and Arrow devices
Main Results and Discussion
Comparison of total ion chromatograms and SIM traces showed that the 1.10 mm SPME Arrow yielded approximately a fourfold increase in signal for guaiacol and a sevenfold increase for 4-methylguaiacol relative to the 100 µm fiber.Additional phenolic compounds commonly associated with smoke-impacted wine, such as cresols, phenols and ethylphenol isomers, also exhibited enhanced responses with the Arrow format, confirming its superior sorption phase volume and extraction efficiency.
Benefits and Practical Applications
- Enhanced sensitivity and lower detection limits for volatile phenols in complex matrices
- Improved reproducibility and mechanical robustness compared to fragile fibers
- Reduced analysis time and solvent consumption through direct headspace extraction and thermal desorption
- Ideal for quality control of wine smoke taint, flavor profiling and environmental monitoring
Future Trends and Prospects
As SPME Arrow technology gains adoption, continued development of novel sorbent coatings and automated workflows will expand its applicability to a wider range of analytes and matrices, including environmental pollutants, clinical biomarkers and food contaminants.Integration with two-dimensional GC and high-resolution MS promises further gains in selectivity and sensitivity for trace-level analysis.
Conclusion
The Agilent DVB/carbon WR/PDMS SPME Arrow (1.10 mm) demonstrates a clear advantage in extraction efficiency and signal enhancement for volatile phenols compared to traditional fibers, supporting its use in high-sensitivity applications such as smoke-taint analysis in wines.Its robust design and larger sorptive volume make it a valuable tool for modern analytical laboratories seeking improved performance and throughput.
Reference
- PAL Smart SPME Arrows: Bigger, Smarter, Better. CTC Analytics AG, 2020.
- Westland J; Abercrombie V. Analysis of Free Volatile Phenols in Smoke-Impacted Wines by SPME. Agilent Technologies Application Note 5994-3161EN, 2021.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Free Volatile Phenols in Smoke-impacted Wines using GC/MS - Consumable Workflow Ordering Guide
2021|Agilent Technologies|Guides
Analysis of Free Volatile Phenols in Smoke-impacted Wines using GC/MS Consumable Workflow Ordering Guide OCH3 OCH3 OH OH CH3 Analysis of Free Volatile Phenols in Smoke-impacted Wines using GC/MS With the increase in wildfires over various regions around the globe,…
Key words
spme, spmesmoke, smokecresol, cresolphenols, phenolswines, winesimpacted, impactedvolatile, volatilepredesorption, predesorptionarrow, arrowheatex, heatexguaiacol, guaiacolagilent, agilentimpact, impactfiber, fibersupplies
Use of Salt to Increase Analyte Concentration in SPME Headspace Applications
2021|Agilent Technologies|Applications
Application Brief Food Testing and Agriculture Use of Salt to Increase Analyte Concentration in SPME Headspace Applications Author Jessica Westland Agilent Technologies, Inc. Abstract Static headspace gas chromatography is one of the most frequently used techniques for the analysis of…
Key words
guaiacol, guaiacolsalt, saltreplicate, replicatesmoke, smokepredesorption, predesorptionnacl, naclcompounds, compoundsheatex, heateximplicated, implicatedspme, spmecresol, cresolheadspace, headspacedvb, dvbstirrer, stirrersample
Advances in Food Testing & Environmental Analysis - Application Compendium
2021|Agilent Technologies|Guides
Advances in Food Testing & Environmental Analysis Application Compendium Table of Contents This application compendium outlines a range of methods from food and beverage testing to dioxin and volatile organic compounds analysis. Click on the titles below for full details...…
Key words
spme, spmesmoke, smokeguaiacol, guaiacolwere, werecresol, cresolsample, sampleheadspace, headspacecounts, countsmethod, methodcompounds, compoundsted, tedhfbi, hfbivolatile, volatilecalibration, calibrationdioxins
Analysis of Free Volatile Phenols in Smoke-Impacted Wines by SPME
2021|Agilent Technologies|Applications
Application Note Food Testing and Agriculture Analysis of Free Volatile Phenols in Smoke-Impacted Wines by SPME Authors Jessica Westland and Vanessa Abercrombie Agilent Technologies, Inc. Abstract Ever since the 2003 wildfires in Australia and British Columbia, smoke impact has been…
Key words
smoke, smokecresol, cresolwine, wineguaiacol, guaiacolgrapes, grapesspme, spmephenols, phenolsnoir, noirpinot, pinotfranzia, franziaimpact, impactloq, loqvolatile, volatilefree, freerelative