Agilent 5975T LTM GC/MSD
Brochures and specifications | 2013 | Agilent TechnologiesInstrumentation
Modern field-based analysis demands laboratory-level performance outside the controlled environment of a central laboratory. The Agilent 5975T Low Thermal Mass GC/MSD bridges this gap by offering a compact, transportable system that maintains the reliability, sensitivity, and throughput of high-end bench-top instruments. This capability is critical for timely decision making in environmental monitoring, homeland security, food safety, and forensic applications.
The primary goal of the Agilent 5975T LTM GC/MSD design is to deliver fast, high-quality gas chromatography/mass spectrometry data in mobile settings. By integrating proprietary low thermal mass column technology with a durable, anti-vibration platform and energy-efficient components, the system aims to:
The 5975T employs several innovative elements:
Field and laboratory tests demonstrate that the 5975T:
The 5975T offers laboratories and field teams:
Advancements likely to enhance the 5975T platform include:
The Agilent 5975T LTM GC/MSD combines cutting-edge thermal management, robust hardware, and powerful software to deliver laboratory-quality GC/MS analysis wherever it is needed. Its unique blend of speed, sensitivity, and portability makes it an indispensable tool for on-site decision makers, enabling timely, accurate results across a broad spectrum of applications.
GC/MSD, GC/SQ
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Modern field-based analysis demands laboratory-level performance outside the controlled environment of a central laboratory. The Agilent 5975T Low Thermal Mass GC/MSD bridges this gap by offering a compact, transportable system that maintains the reliability, sensitivity, and throughput of high-end bench-top instruments. This capability is critical for timely decision making in environmental monitoring, homeland security, food safety, and forensic applications.
Objectives and Overview
The primary goal of the Agilent 5975T LTM GC/MSD design is to deliver fast, high-quality gas chromatography/mass spectrometry data in mobile settings. By integrating proprietary low thermal mass column technology with a durable, anti-vibration platform and energy-efficient components, the system aims to:
- Reduce cycle times and power consumption compared to conventional GC/MS units
- Support a wide mass range (1.8–1050 amu) and multiple sampling modes
- Enable seamless transition between field deployment and routine laboratory use
Methodology and Instrumentation
The 5975T employs several innovative elements:
- Low Thermal Mass (LTM) Technology: Heaters and sensors wrap directly around the GC column to achieve ramp rates up to 1200 °C/min. This design cuts power requirements by nearly half and shrinks footprint and weight by over one-third.
- Inert High-Temperature Ion Source: Programmable up to 350 °C, this source minimizes surface reactions and extends run intervals with consistent library match quality.
- Hyperbolic Quartz Quadrupole: True hyperbolic electrodes ensure dimensional stability under temperature fluctuations, delivering reliable resolution to 1050 amu.
- Synchronous SIM/Scan Acquisition: Simultaneous selected ion monitoring and full-scan collection boost sensitivity without sacrificing library-searchable data.
- Trace Ion Detection: Reduces false negatives and improves spectral fidelity for complex matrices by lowering detection limits and automating baseline integration.
- Deconvolution Reporting Software (DRS): Automates spectral cleaning, library searches, and target quantitation to cut review times from hours to minutes.
- Retention Time Locking (RTL) Database: Predefined libraries of retention times and spectra accelerate compound confirmation across diverse applications (PAHs, VOCs, pesticides, etc.).
Main Results and Discussion
Field and laboratory tests demonstrate that the 5975T:
- Separates and identifies chemical warfare agents (sarin, soman, mustard gas, VX) in under 10 minutes with no matrix interference.
- Analyzes over 60 VOCs in ambient air using a mini thermal desorber or capillary trap sampler with cycle times under 15 minutes.
- Meets EPA Method 524.2 by resolving 54 drinking-water VOCs in 9 minutes with detection limits below 1 µg/L.
- Detects and confirms 59 pesticides in produce samples using QuEChERS extraction, DRS, and RTL libraries in a blind study with 100% identification success.
Benefits and Practical Applications
The 5975T offers laboratories and field teams:
- One versatile system for both mobile and bench-top analysis, reducing capital and maintenance costs.
- Rapid startup enabled by vacuum-keeping technology, cutting warm-up time by at least one hour.
- Energy-efficient operation with 46% less power consumption, supporting green laboratory initiatives.
- Compatibility with a broad range of samplers (mini TD, headspace, purge-and-trap, liquid autosamplers, thermal probes), maximizing workflow flexibility.
Future Trends and Applications
Advancements likely to enhance the 5975T platform include:
- Integration of wireless data transfer and remote diagnostics to streamline field operations.
- Expanded use of automated sample preparation modules for on-site high-throughput testing.
- Miniaturized, multi-dimensional GC architectures for even faster separations and improved resolution.
- Application in emerging fields such as UAV-mounted sampling and real-time environmental hazard detection.
Conclusion
The Agilent 5975T LTM GC/MSD combines cutting-edge thermal management, robust hardware, and powerful software to deliver laboratory-quality GC/MS analysis wherever it is needed. Its unique blend of speed, sensitivity, and portability makes it an indispensable tool for on-site decision makers, enabling timely, accurate results across a broad spectrum of applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
3-in-1 Solution for Mobile Forensic Applications
2014|Agilent Technologies|Applications
3-in-1 Solution for Mobile Forensic Applications Application Note Forensic Toxicology Author Abstract Suli Zhao The Agilent 5975T LTM GC/MS, when configured with the Capillary Trap Sampler Agilent Technologies, Inc. (CTS) and Thermal Separation Probe (TSP), is capable of measuring compounds…
Key words
tsp, tspcts, ctsfire, fireblood, bloodforensic, forensicdebris, debrisdrugs, drugsconvincible, convinciblejeans, jeanssolid, solidashes, ashesthrown, thrownwhole, wholeinformatiom, informatiomsuli
Accelerated Analysis of On-Site Pesticide Detection in Vegetables by Agilent 5975T LTM GC/MSD and TSP
2011|Agilent Technologies|Applications
Accelerated Analysis of On-Site Pesticide Detection in Vegetables by Agilent 5975T LTM GC/MSD and TSP Application Note Food Diagnostic Authors Abstract Suli Zhao, Andy Zhai Thermal separation probe (TSP) is a rapid, rugged, and inexpensive approach to gas Agilent Technologies…
Key words
tsp, tsppesticide, pesticidedrs, drsgcms, gcmssampliq, sampliqamdis, amdissample, samplesalt, saltagilent, agilenttest, testfenvalerate, fenvaleratertl, rtldeltamethrin, deltamethrinvegetables, vegetablesclean
Agilent 5975T LTM GC/MSD System - Data Sheet
2011|Agilent Technologies|Brochures and specifications
Agilent 5975T LTM GC/MSD System Data Sheet LTM GC/MSD The Agilent 5975T LTM GC/MSD is the first commercial transportable GC/MS system that delivers laboratory quality analysis. The 5975T takes advantage of Agilent’s proprietary LTM technology, which eliminates the conventional GC…
Key words
ltm, ltmrtl, rtlsim, simturntop, turntopmaintenance, maintenancedrs, drstemperature, temperaturenoncondensing, noncondensinginlet, inletscan, scancontrol, controlaxis, axislibraries, librariesmass, masshyperbolic
EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace
2010|Agilent Technologies|Applications
EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace Application Note Environmental Authors Abstract Xiaohua Li Due to an increase in urgent cases of water pollution, requirements for onsite water Agilent…
Key words
pass, passvocs, vocsltm, ltmdrs, drstemp, tempwater, waterbfb, bfbbutylbenzene, butylbenzenecalibration, calibrationabn, abnheadspace, headspacetransportable, transportablecompounds, compoundsamdis, amdisdeconvolution