Rapid Qualitative GC-TOFMS Analysis of Unleaded Gasoline
Applications | 2010 | LECOInstrumentation
Characterization of complex mixtures such as unleaded gasoline is essential for quality control, environmental monitoring, and regulatory compliance. Rapid profiling of hundreds of volatile and semi-volatile compounds supports efficient decision-making in petrochemical analysis.
This study demonstrates a fast qualitative GC-TOFMS method using the LECO Pegasus II for an unleaded gasoline sample. The goal was to reduce total run time and data processing without compromising compound identification accuracy.
A 14-minute fast GC program was employed on a Hewlett Packard 6890 GC with a narrow-bore DB-1 column (20 m×0.1 mm ID, 0.4 µm). Key conditions included a 0.2 µL split injection (1000:1), helium carrier gas at 0.6 mL/min, oven ramp from 40 °C to 260 °C at up to 20 °C/min, and mass spectral acquisition up to 500 spectra/s. Proprietary Peak Find and Deconvolution algorithms were used to detect and resolve coeluting compounds.
The method enabled identification of 573 analytes in 14 minutes—a tenfold reduction in analysis time. Peak Find accurately located narrow peaks, including complex C7 hydrocarbon coelutions. Deconvolution separated overlapping spectra and correctly apportioned shared ion signals, yielding high similarity scores against the NIST library.
Further improvements in fast GC hardware and TOFMS acquisition speeds will shorten run times. Enhanced deconvolution algorithms and growing spectral databases will boost identification confidence. Coupling with automated sampling and advanced data analytics could enable real-time process control.
The integration of fast GC separation, high-speed TOFMS acquisition, and specialized software deconvolution on the Pegasus II platform achieves reliable qualitative analysis of complex gasoline samples in just 14 minutes. This workflow delivers over an order-of-magnitude reduction in total analysis time while preserving data quality, offering significant efficiency gains for routine petrochemical testing.
GC/MSD, GC/TOF
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies, LECO
Summary
Significance of the topic
Characterization of complex mixtures such as unleaded gasoline is essential for quality control, environmental monitoring, and regulatory compliance. Rapid profiling of hundreds of volatile and semi-volatile compounds supports efficient decision-making in petrochemical analysis.
Objectives and Study Overview
This study demonstrates a fast qualitative GC-TOFMS method using the LECO Pegasus II for an unleaded gasoline sample. The goal was to reduce total run time and data processing without compromising compound identification accuracy.
Methodology and Instrumentation
A 14-minute fast GC program was employed on a Hewlett Packard 6890 GC with a narrow-bore DB-1 column (20 m×0.1 mm ID, 0.4 µm). Key conditions included a 0.2 µL split injection (1000:1), helium carrier gas at 0.6 mL/min, oven ramp from 40 °C to 260 °C at up to 20 °C/min, and mass spectral acquisition up to 500 spectra/s. Proprietary Peak Find and Deconvolution algorithms were used to detect and resolve coeluting compounds.
Used Instrumentation
- Gas Chromatograph: HP 6890 with fast ramp EPC
- Column: DB-1, 20 m×0.1 mm, 0.4 µm film
- Mass Spectrometer: LECO Pegasus II Time-of-Flight
- Transfer line: 275 °C; Ion source: 210 °C
- Acquisition rate: 50–500 spectra/s
Key Results and Discussion
The method enabled identification of 573 analytes in 14 minutes—a tenfold reduction in analysis time. Peak Find accurately located narrow peaks, including complex C7 hydrocarbon coelutions. Deconvolution separated overlapping spectra and correctly apportioned shared ion signals, yielding high similarity scores against the NIST library.
Benefits and Practical Applications
- High-throughput fuel profiling for petrochemical and QC laboratories
- Automated peak detection and deconvolution minimize manual data review
- Supports environmental monitoring by rapid VOC analysis
Future Trends and Opportunities
Further improvements in fast GC hardware and TOFMS acquisition speeds will shorten run times. Enhanced deconvolution algorithms and growing spectral databases will boost identification confidence. Coupling with automated sampling and advanced data analytics could enable real-time process control.
Conclusion
The integration of fast GC separation, high-speed TOFMS acquisition, and specialized software deconvolution on the Pegasus II platform achieves reliable qualitative analysis of complex gasoline samples in just 14 minutes. This workflow delivers over an order-of-magnitude reduction in total analysis time while preserving data quality, offering significant efficiency gains for routine petrochemical testing.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard
2010|Agilent Technologies|Applications
® Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, Petrochemical, Deconvolution 1. Introduction Analyses of petroleum products are complicated by the relatively large number of volatile components contained in…
Key words
similarity, similarityreverse, reversesec, secformula, formulapegasus, pegasuspeak, peakpetroleum, petroleumname, namealgorithms, algorithmsreformate, reformatedeconvolution, deconvolutionspectra, spectrascience, sciencerefinery, refinerycoelution
Determination of Hydrocarbon Components in Petroleum Naphthas
2010|Agilent Technologies|Applications
® Determination of Hydrocarbon Components in Petroleum Naphthas LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, Petrochemical, Naphtha, Deconvolution, Retention Index Mass spectrometers are usually used as a confirmation tool only, perhaps because a mass spectrometer is perceived to…
Key words
olefin, olefinnaphthas, naphthasparaffin, paraffinarea, areapegasus, pegasusiso, isocoeluting, coelutingdeconvolute, deconvolutechromatographic, chromatographicethylcyclopentane, ethylcyclopentanenaphthene, naphtheneindex, indexpeak, peakspectrum, spectrumcan
Analysis of Grape Volatiles by Solid Phase Microextraction and Comprehensive Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry (GCxGC-TOFMS)
2008|Agilent Technologies|Applications
® Analysis of Grape Volatiles by Solid Phase Microextraction and Comprehensive Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry (GCxGC-TOFMS) LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-TOFMS, SPME, Food and Flavors The aim of this work was to study…
Key words
isomer, isomerester, estergcxgc, gcxgcgrapes, grapesvarietal, varietalindene, indeneacid, acidethyl, ethylbutanoic, butanoicionone, iononehexanoic, hexanoicdodecane, dodecanegrape, grapescience, sciencechromatof
Qualitative GC-TOFMS Analysis of Nutmeg Extract: Automated Peak Finding and Spectral Deconvolution of Minor Components
2010|Agilent Technologies|Guides
® Qualitative GC-TOFMS Analysis of Nutmeg Extract: Automated Peak Finding and Spectral Deconvolution of Minor Components LECO Corporation; Saint Joseph, Michigan USA Key Words: GC-TOFMS, Food, Deconvolution 1. Introduction Nutmeg is one of the old spices, having been cultivated for…
Key words
pegasus, pegasuscis, cisterpineol, terpineolpeak, peaktrans, transsabinenehydrate, sabinenehydratecoelution, coelutionnutmeg, nutmegalgorithms, algorithmsfind, findcomponents, componentsocimene, ocimenedeconvolution, deconvolutionspectral, spectraleugenol