Importance of the Topic


Environmental contamination of seafood by petroleum hydrocarbons and polycyclic aromatic hydrocarbons (PAHs) poses significant risks to human health and fisheries economics. Reliable, rapid, and cost-effective analytical approaches are essential to support regulatory decision-making for reopening affected fishing areas. Innovations in sample preparation and advanced gas chromatography techniques enable high-throughput monitoring and sensitive detection of PAHs in complex food matrices.

Study Objectives and Overview


This whitepaper examines established regulatory protocols (FDA and NOAA) for assessing petroleum contamination in seafood and evaluates the QuEChERS sample preparation workflow as an efficient alternative. It also compares performance of single-quadrupole (GC-Q) and triple-quadrupole (GC-QQQ) GC-MS platforms, coupled with capillary flow backflush technology, for PAH quantitation in finfish and shellfish.

Methodology and Instrumentation


The study comprises two main parts:
  • Regulatory Framework and NOAA Protocols: Outlines FDA’s nine priority PAHs and NOAA’s sample closure criteria, including organoleptic and chemical testing.
  • QuEChERS Workflow: A streamlined extraction and cleanup approach using acetonitrile partitioning and dispersive SPE sorbents. Key steps:
    • Homogenize and spike samples with internal standards.
    • Extract with acidified acetonitrile and partition with salting-out reagents.
    • Clean up extracts via dispersive SPE and centrifugation.

Instrumentation


Analysis performed on two Agilent platforms:
  • 7890A GC coupled to 7000B QQQ-MS (triple quadrupole) with multimode inlet and DB-EUPAH column.
  • 7890A GC with 5975C single-quadrupole MS in SIM mode, featuring capillary flow backflush union.
  • Column backflush reduces carryover, retention time shifts and maintenance, enabling faster cycle times.

Main Results and Discussion


Comparative data demonstrate:
  • QuEChERS enables PAH extraction in 10 minutes versus overnight for traditional NOAA methods, with reduced solvent and glassware usage.
  • GC-QQQ achieves lower detection limits (sub-pg levels) and more reliable MRM ratios in complex extracts compared to GC-Q SIM.
  • Backflush technology eliminates retention time drift and matrix buildup, cutting analysis time by up to 20 minutes per run.
  • Recovery of 29 EPA PAHs from mussel tissue spiked at 125 ppb ranged consistently across both platforms.

Benefits and Practical Applications


  • High sample throughput: dozens of samples per day using QuEChERS.
  • Cost savings: reduced solvent consumption and disposal.
  • Analytical robustness: minimized operator error and maintenance downtime.
  • Regulatory compliance: meets FDA and NOAA guidelines for seafood safety assessment.

Future Trends and Potential Applications


Emerging opportunities include:
  • Expansion of QuEChERS to other food matrices and environmental samples.
  • Integration of high-resolution MS for non-target screening of novel contaminants.
  • Automation of sample preparation to further increase laboratory productivity.
  • Development of portable GC-MS systems for rapid field screening of PAHs.

Conclusion


The combination of QuEChERS sample preparation with advanced GC-QQQ and GC-Q systems provides a powerful solution for rapid, sensitive, and reliable PAH analysis in seafood. Capillary flow backflush enhances instrument uptime and consistency. This integrated approach supports regulatory compliance and protects public health while reducing operational costs.

References


  • Sloan C.A., Brown D.W., Pearce R.W., et al. Extraction, Cleanup, and GC/MS Analysis of Sediments and Tissues for Organic Contaminants. NOAA Tech Memo. NMFS-NWFSC-59; 2004.
  • NOAA. Protocol for Interpretation and Use of Sensory Testing and Analytical Chemistry Results for Re-Opening Oil-Impacted Areas Closed to Seafood Harvesting. NOAA Opening Protocol; 2010.
  • Sandy C. The Analysis of PAHs in Biota and Sediment Extracts Using GC-MS/MS with Agilent 7000A. Agilent Technologies UK; 2009.
  • Smith D., Lynam K. GC/MS Analysis of EU Priority PAHs Using DB-EUPAH Column. Agilent Technologies USA; 2009.
  • Ramalhosa M.J., Araújo A.N., Maciel M.I.S. Analysis of PAHs in Fish: Evaluation of a QuEChERS Method. J Sep Sci. 2009;32:3529–3538.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Advanced Analytical Technologies for Analyzing Environmental Matrixes Contaminated with Petroleum Hydrocarbons - QuEChERS with GC-Q and GC-QQQ PAH Analyzers
QuEChERS with Advanced Analytical GC-Q and GC-QQQ Technologies for Analyzing Environmental PAH Analyzers Matrixes Contaminated Fred Feyerherm with Petroleum Application Chemist Hydrocarbons October, 12, 2010 [email protected] 1 References ”Extraction, Cleanup, and Gas Chromatography/Mass Spectrometry Analysis of Sediments and Tissues for…
Key words
quechers, quechersbenzo, benzoqqq, qqqpyrene, pyrenefluoranthene, fluorantheneconfidentiality, confidentialityanthracene, anthracenelabel, labelbackflushing, backflushingperylene, peryleneratios, ratiospah, pahdoh, dohtriphenylene, triphenylenestd
Agilent Solutions for Analyzing Polycyclic Aromatic Hydrocarbons in Seafood
Agilent Solutions for Analyzing Polycyclic Aromatic Hydrocarbons in Seafood Jim McCurry October 2010 PAH analytical method summary  NOAA NMFS-NWFSC-59, 2004 GPC + GC/MS is the current method specified for PAH analysis in seafood. It is a complex and time-consuming…
Key words
fluoranthene, fluoranthenebenzo, benzopah, pahanthracene, anthracenepyrene, pyrenebenz, benzanalyzers, analyzersseafood, seafoodquechers, quechersperylene, perylenefactory, factoryacenaphthylene, acenaphthyleneqqq, qqqacenaphthene, acenaphthenefluorene
Polycyclic Aromatic Hydrocarbon (PAH) Analysis in Fish by GC/MS Using Agilent Bond Elut QuEChERS dSPE Sample Preparation and a High Efficiency DB-5ms Ultra Inert GC Column
Polycyclic Aromatic Hydrocarbon (PAH) Analysis in Fish by GC/MS Using Agilent Bond Elut QuEChERS dSPE Sample Preparation and a High Efficiency DB-5ms Ultra Inert GC Column Application Note Food Testing and Hydrocarbon Processing Authors Abstract Doris Smith and Ken Lynam…
Key words
fluoranthene, fluoranthenebenzo, benzopyrene, pyreneanthracene, anthracenefish, fishquechers, quechersbenz, benzphenanthrene, phenanthrenepahs, pahselut, elutnoaa, noaabond, bondagilent, agilentacenaphthylene, acenaphthylenefluorene
PAH Analysis in Fish by GC/MS Using QuEChERS/dSPE Sample Preparation and High Efficiency GC Columns
PAH Analysis in Fish by GC/MS Using QuEChERS/dSPE Sample Preparation and High Efficiency GC Columns Kenneth G. Lynam, Doris Smith, and Joan Stevens Agilent Technologies, Inc. 2850 Centerville Rd. Wilmington, DE USA 19808 Introduction The Deep Water Horizons disaster in…
Key words
fluoranthene, fluoranthenebenzo, benzopahs, pahspyrene, pyrenefish, fishanthracene, anthracenebenz, benzpah, pahquechers, quechersacenaphthylene, acenaphthylenepolycyclic, polycyclicnapthalene, napthalenefluorene, fluorenephenanthrene, phenanthrenechrysene
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike