GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Using GC/MSD with High Efficiency Source and JetClean to detect low level contaminants in ethylene and propylene

Posters | 2018 | Agilent TechnologiesInstrumentation
GC/MSD, GC/SQ
Industries
Energy & Chemicals
Manufacturer
Agilent Technologies

Summary

Significance of the Topic


Beer flavor profiling is essential to quality control, flavor development, and authentication within the brewing industry. Static headspace GC/MS enables efficient detection of volatile and semi-volatile compounds—aldehydes, higher alcohols, esters, and organic acids—that define beer’s sensory profile.

Study Objectives and Overview


  • Evaluate static headspace GC/MS with a highly inert Agilent J&W DB-624UI column for comprehensive beer analysis.
  • Compare organic acid response and chromatographic performance against a competitor phase.
  • Demonstrate flavor profiling across a range of summer-style beers.

Methodology and Instrumentation


  • Headspace sampler: Agilent 7697A (85 °C oven, 1 mL loop, 20 min equilibration).
  • Capillary column: Agilent J&W DB-624UI 30 m × 0.32 mm i.d. × 1.8 μm phenylnitrile.
  • Carrier gas: Helium at approx. 2.6 mL/min (constant flow).
  • GC temperature program: 35 °C hold, ramp to 100 °C then to 220 °C with specified holds.
  • Detection: MS scan (30–400 amu) complemented by FID.

Results and Discussion


Organic acids including acetic, propionic, butanoic, and octanoic exhibited sharply improved peak shapes and detection sensitivity on the inert DB-624UI column, while the competitor phase showed severe tailing and loss of low-level acids. Static headspace profiles of various summer-style beers revealed distinctive patterns of aldehydes, higher alcohols, and esters, enabling clear differentiation of beer styles.

Benefits and Practical Applications of the Method


  • Robust detection of challenging polar organic acids.
  • Reliable flavor profiling for quality assurance and stability monitoring.
  • Flavor fingerprinting for product authentication and style classification.

Future Trends and Opportunities


  • Integration with chemometric tools for automated style recognition.
  • Development of next-generation inert stationary phases to further enhance sensitivity.
  • On-line headspace sampling for real-time process monitoring in brewing.

Conclusion


Static headspace GC/MS using a highly inert DB-624UI capillary column delivers superior organic acid response and comprehensive flavor profiling in beer analysis. This approach supports brewing quality control, sensory development, and product authentication.

References


  • Agilent Publication #5991-1136EN: Screen Beer by GC/MS Static Headspace with the Agilent J&W DB-624UI Ultra Inert Capillary Column.
  • Agilent Publication #5991-6638EN: Analysis of Distilled Spirits Using an Agilent J&W DB-Wax Ultra Inert Capillary GC Column.
  • Agilent Publication #5991-0659EN: Agilent J&W DB-624 Ultra Inert Capillary Column Screens Distilled Spirits by GC Static Headspace.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
What’s in Your Beer? Part 2: GC/MS Static Head Space with a Highly Inert 624 Capillary GC Column
What’s in Your Beer? Part 2: GC/MS Static Head Space with a Highly Inert 624 Capillary GC Column Introduction Some ingredients in beer can be challenging to separate and chromatograph. Common beer flavor components include; fusel oils, aldehydes, esters, and…
Key words
ethyl, ethylacetate, acetatealdehyde, aldehydeisobutyl, isobutylacid, acidalcohol, alcoholacetyl, acetylbeer, beerisoamyl, isoamylethanol, ethanolbeers, beersoctanoic, octanoicamly, amlychromatogram, chromatogramacetic
What’s in Your Beer? GC/MS Static Head Space with a DB-624 Ultra Inert Capillary GC Column
What’s in Your Beer? GC/MS Static Head Space with a DB-624 Ultra Inert Capillary GC Column AOAC 2012 Authenticity P-T-013 Joan Stevens1, Trisa Robarge1,, and Kenneth Lynam (Agilent Technologies Inc., Lake Forest, CA1,, Wilmington DE2) Abstract Static head space GC/MS…
Key words
ethyl, ethylacetate, acetatealcohol, alcoholisoamyl, isoamylisobutyl, isobutylacid, acidoctanoic, octanoicdecanoate, decanoatealdehyde, aldehydelinolool, linoloolacetyl, acetylhexanoate, hexanoatebeer, beeramyl, amylpropyl
What’s in Your Beer? GC/MS Static Head Space with an Agilent J&W DB-624 Ultra Inert Capillary GC Column
What’s in Your Beer? GC/MS Static Head Space with an Agilent J&W DB-624 Ultra Inert Capillary GC Column Pittsburgh Conference Poster# 1510-30P Gary Lee1 and Kenneth Lynam2 (Agilent Technologies Inc. Folsom, CA1 , Wilmington DE2) Abstract Static head space GC/MS…
Key words
ethyl, ethylacetate, acetatealcohol, alcoholisoamyl, isoamylisobutyl, isobutylacid, acidoctanoic, octanoicdecanoate, decanoatealdehyde, aldehydelinolool, linoloolacetyl, acetylhexanoate, hexanoatebeer, beeramyl, amylpropyl
Screen Beer by GC/MS Static Headspace with the Agilent J&W DB-624 Ultra Inert Capillary Column
Screen Beer by GC/MS Static Headspace with the Agilent J&W DB-624 Ultra Inert Capillary Column Application Note Food Testing & Agriculture Author Ken Lynam Agilent Technologies, Inc. Abstract This application note highlights the utility of Agilent J&W DB-624UI columns for…
Key words
ethyl, ethylacetate, acetateacid, acidaldehyde, aldehydebeer, beeroctanoic, octanoicisoamyl, isoamylflavor, flavorisobutyl, isobutylamyl, amylfermentation, fermentationbutanoic, butanoicalcohol, alcoholpropionic, propionicactive
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike